Sec. 18-4. - Applicability of chapter to existing buildings and building service equipment.
(a) Generally. The legal use and occupancy of any structure existing on the date of adoption of this chapter shall be permitted to continue without change provided such continued use is not dangerous to life, and as may be specifically covered in this chapter, the fire code or as may be deemed necessary by the building official for the general safety and welfare of the occupants and the public. (b) Ordinary repairs. Application or notice to the building official is not required for ordinary repairs to structures, replacement of lamps or the connection of approved portable electrical equipment to approved permanently installed receptacles. Such repairs shall not include the cutting away of any wall, partition or portion thereof, the removal or cutting of any structural beam or load bearing support, or the removal or change of any required means of egress, or rearrangement of parts of a structure affecting the egress requirements, nor shall ordinary repairs include addition to, alteration of, replacement or relocation of any standpipe, water supply, sewer drainage, drain leader, gas, soil, waste, vent or similar piping; electric wiring; or mechanical or other work affecting public health or general safety. (c) Exit enclosures for existing buildings. (1) Scope. The provisions of this subsection (c) shall apply to existing group R-1 and R-2 occupancies, that is, apartments and hotels three stories or more in height. (2) Enclosures required. Unless otherwise excepted by subsection (c)(6)f of this section, every interior stairway, ramp or escalator shall be enclosed as specified in this section. (3) Enclosure construction. Every interior stairway, ramp or escalator shall be enclosed with walls of not less than one-hour fire resistive construction. Where existing partitions form part of a stairwell enclosure, wood lath and plaster in good condition or one-half-inch gypsum wallboard in good condition, or an equivalent approved by the building official, may be substituted for one-hour fire resistive construction. (4) Openings into enclosures. There shall be no openings into exit enclosures except exit doorways and openings in exterior walls. Doors in stairway, ramp and escalator enclosures shall be protected by a self-closing solid wood door not less than 1¾ inches thick, or an equivalent approved by the building official. Enclosures shall include landings between flights and corridors, passageways or public rooms necessary for continuous exit to the exterior of the building. (5) Approval by building official. When presented with a request for permission to substitute construction type or material under the provisions of this section, the building official shall consider, but is not limited to, similar provisions of this Code and related standards, the fire code, the use of requested substitution in common construction practice, federal and state recommendations, and the level of safety afforded inhabitants of the building by the substitution. (6) Exceptions. The provisions of subsections (c)(1) through (5) of this section shall not apply to the following situations: a. The stairway, ramp or escalator need not be enclosed in a continuous shaft if cut off at each story by the fire resistive construction required by this section for stairway, ramp and escalator enclosures. b. An enclosure shall not be required for a stairway, ramp or escalator serving only one adjacent floor and not connected with corridors or stairways serving other floors. c. Stairs within individual apartments and hotel rooms need not be enclosed. d. Buildings with at least one functional interior enclosed stairwell providing access from each apartment or hotel room may have unprotected secondary exits. e. Stairwells, ramps and escalator enclosures in buildings five or fewer stories in height with an exterior stairway or fire escape serving as a secondary exit from each apartment or hotel room need not be enclosed, provided access from each apartment or hotel room is directly onto the exterior stairway or fire escape. f. An enclosure shall not be required for stairways, ramps or escalators in lobby or mezzanine areas not leading to sleeping areas. g. Enclosures shall not be required if an automatic sprinkler system is provided for the stairway, ramp or escalator area. (7) Alternative standards. In addition to the powers and duties of the building and fire codes board of appeals as set forth in section 18-12, the board may consider the cost of proposed retrospective requirements if raised by the appellant. In cases of gross economic hardship, determined by considering but not being limited to any of the following elements, it may require alternative fire prevention and safety measures: sale value of the building, value of the building less present encumbrances, availability of financing, appellant's net worth, effect on tenants and public, and the degree of additional protection fire resistant material and enclosed stairwells would provide. (d) Underground space. (1) Generally. Underground space to which additions, alterations or repairs are made shall comply with all the requirements for new space except as specifically provided in this section. Improvements such as building construction within such existing underground space shall be regulated as applicable by requirements of this chapter including modifications in article XI of this chapter. (2) Additions, alterations and repairs of more than 50 percent. When additions, alterations or repairs of underground space within any 12-month period exceed 50 percent of the area of an existing underground space, such space shall be made to conform to the requirements for new underground space. (3) Additions alterations and repairs of 25 to 50 percent. Additions, alterations and repairs exceeding 25 percent but not exceeding 50 percent of the area of an existing underground space and complying with the requirements for new space may be made to such space within any 12-month period, without making the entire space comply. (4) Additions, alterations and repairs of 25 percent or less. Structural additions, alterations and repairs to any portion of an existing underground space, within any 12-month period, not exceeding 25 percent of the area of the space shall comply with all the requirements for new space; except that minor structural additions, alterations or repairs, when approved by the building official, may be made with the same materials of which the space is constructed. (5) Continuation of existing occupancy. Underground space in existence on December 16, 1982, may have its existing use or occupancy continued, if such use or occupancy was legal at that time, providing such continued use is not dangerous to life. (6) Maintenance. All underground space, both existing and new, and all parts thereof, shall be maintained in a safe and sanitary condition. All devices or safeguards which are required by this article in a space when developed, altered or repaired shall be maintained in good working order. The owner or his designated agent shall be responsible for the maintenance of underground space. (e) Construction in floodplain. The provisions of chapter 28 of the Code of Ordinances must be met for any alteration, encroachment or substantial improvement accomplished in a regulatory floodplain as designated on the official floodplain document.
(Ord. No. 200418, § 1, 6-18-20)
Ask a question about Kansas City law
Corpus searches the Kansas City sections it holds and shows the ones that match, with their citations. Free, no sign-in.