Sec. 8-403. - Required facilities.
(a) Sanitary facilities required. Every dwelling unit shall contain not less than a kitchen sink, lavatory, tub or shower and a water closet all in good working condition and properly connected to any approved water and sewer system. Every plumbing fixture and water and waste pipe shall be properly installed and maintained in good sanitary working condition, free from defects, leaks, and obstructions.
(b) Location of sanitary facilities. All required plumbing fixtures shall be located within the dwelling unit and be accessible to the occupants of same. The water closet, tub, or shower and lavatory shall be located in a room affording privacy to the user.
(c) Hot and cold water supply. Every dwelling unit shall have connected to the kitchen sink, lavatory, and tub or shower an adequate supply of both cold water and hot water. All water must be supplied through an approved pipe distribution system connected to an approved potable water supply.
(d) Water heating facilities. Every dwelling shall have water heating facilities which are properly installed and maintained in a safe and good working condition and are capable of heating water to such a temperature as to permit an adequate amount of water to be drawn at every required kitchen sink, lavatory basin, bathtub or shower at a temperature of not less than one hundred twenty (120) degrees Fahrenheit. All water heaters shall be equipped with approved temperature and pressure relief valves, and a relief line of proper size leading to a safe area for discharge.
(e) Heating facilities. Every dwelling unit shall have heating facilities which are properly installed and maintained in safe and good working condition, or shall be provided with sufficient fireplaces, chimneys, flues, or gas risers whereby heating appliances may be connected so as to furnish a minimum temperature of sixty-eight (68) degrees Fahrenheit in all habitable rooms and bathrooms, measured at a point three (3) feet above the floor during ordinary winter conditions. Shut-off valves are required on gas risers when an appliance is connected to the riser. All gas risers are required to be properly capped or plugged when not connected to an appliance.
(f) Cooking and heating equipment. All cooking and heating equipment and facilities shall be installed in accordance with the building, gas or electrical code and shall be maintained in a safe and good working condition.
(g) Garbage disposal facilities. Every dwelling unit shall have adequate garbage disposal facilities or garbage storage containers, the type and location of which facilities or containers are approved by the city.
(Code 1961, § 18-40; Ord. No. 16,155, § 8, 1-21-92; Ord. No. 17,053, § 2, 12-19-95)