§ 51A-13.501 — GENERAL PROVISIONS
Dallas City Code (7/2026 Code (S-33): Vols. I-II current through Ordinance 33447, passed June 10, 2026; Vol. III through Ordinance 33484, passed June 24, 2026) · Dallas City Code § 51A-13.501
Corpus is an independent public-information project, not the official City of Dallas website. Stable reference: corpuslaw.us/code/9d321d9f-57b4-49bb-8e5d-78d2a959200c
SEC. 51A-13.501. GENERAL PROVISIONS.
[image omitted; see the official code] (a) Planting Zone. (1) The planting zone is the area nearest to the curb within the public right-of-way. (2) Street trees must be planted in the planting zone in accordance with the applicable street cross-section (see Section 51A-13.502, “New Minor Streets,” and Section 51A-13.503, “Existing Streets”). (3) One large canopy tree must be planted every 40 feet on center, on average. All street trees must have a minimum caliper of three inches at the time of installation. (4) Where utilities exist or are proposed, two small trees may replace a required large canopy tree except where a mixed-use shopfront or single-story shopfront is proposed or required. If the replacement small trees conflict with utilities and cannot be planted within the planting zoen, the replacement small trees must be planted within the door yard, but no closer than five feet from the building facade. Replacement small trees must be planted as evenly spaced as possible considering utility conflicts. (5) The planting zone may be hardscaped with tree grates or landscaped with a tree lawn. (6) The planting zone must remain clear of obstacles at all times except as provided for in Section 51A-13.501(d), “Encroachments.” (b) Sidewalk Zone. (1) The sidewalk zone is the area between the planting zone and the front property line or right-of-way easement within the public right-of-way. (2) The sidewalk zone must remain clear of obstacles at all times and must be constructed to meet all city and ADA specifications. (c) Door Yard Zone. (1) The door yard is the area between the sidewalk zone and the front building facade. (2) Except in an -SH overlay, the door yard may be hardscaped or landscaped. In a -SH overlay, the door yard must be hardscaped. (3) The door yard must remain clear of obstacles at all times except as specifically provided for in Section 51A-13.501(d), “Encroachments.” (d) Encroachments. (1) Planting Zone. The following encroachments are permitted in the planting zone subject to approval of a license for use of public right-way issued in accordance with Article VI of Chapter 43 of the Dallas City Code. (i) Benches, trash receptacles, newspaper racks, and bicycle racks. (ii) Utility boxes, meters, man hole covers, regulatory signs, and fire suppression equipment. (iii) Pedestrian lighting. (iv) Landscaping, sidewalk, trees, tree grates, and planters. (2) Sidewalk Zone. Except as permitted in Section 51A-13.503(g), “Nonconforming Streetscapes,” no encroachments are permitted over or in the sidewalk zone. (3) Door Yard Zone. The following encroachments are permitted in the door yard. (i) Galleries, awnings, balconies, stoops, and front porches in accordance with Section 51A-13.305, “Building Elements.” (ii) Outdoor seating areas. (iii) A maximum three-foot-high fence. (iv) Outdoor display in accordance with Section 51A-13.602, “Outdoor Storage and Display.” (v) Signs in accordance with Section 51A-13.603, “Signs.” (vi) Benches, trash receptacles, public art, water features, bicycle racks, and bollards. (vii) Pedestrian lighting. (viii) Utility boxes, meters, man hole covers, and fire suppression equipment. (ix) Landscaping, sidewalks, trees, tree grates, and planters. (e) Easements. (1) The sidewalk zone, planting zone, and on-street parking area may be provided on private property provided the sidewalk zone, planting zone, and on-street parking area are located within an easement permanently dedicated to the city. (2) The dedicated easement must provide the city with perpetual access to allow for customary public use, including but not limited to, the provision of public signs, street lighting, parking meters, and public utilities. (3) The easement cannot be used for underground structures of any kind except those associated with underground utilities. (f) Pedestrian Amenities. (1) Applicability. The following pedestrian amenities apply in the WMU and WR districts. (2) Location. Pedestrian amenities must be provided within the door yard or planting zone. (3) Required Amenities. The following pedestrian amenities are required: (i) Benches at one per 300 feet of frontage on at least one primary street. (ii) Trash receptacles at one per 300 feet of frontage on at least one primary street. (iii) Bicycle parking at one five-bicycle rack per 300 feet of frontage on at least one primary street. (4) Optional Amenities. (A) In General. A minimum of two of the pedestrian amenities or enhancements listed in this subparagraph are required to obtain a two percent parking reduction. (B) Galleries, Arcades, and Awnings. Galleries, arcades, or awnings with a minimum length of 25 feet per 100 feet of building facade must be provided along the frontage in accordance with Section 51A-13.305, “Building Elements.” (C) Pedestrian Passage. A mid-block pedestrian passage, available at all times to the general public, must be provided and constructed in accordance with Section 51A-13.502(b)(7), “Pedestrian Passage.” (D) Public Open Space. An additional two percent of net land area must be provided as public open space in accordance with Section 51A-13.304(k), “Open Space Lot,” either on- or off- site (within a walking distance of 1,320 feet). To obtain this credit, the dedication of public open space must be accepted by the city of Dallas. (E) Building Materials. (i) At least 85 percent of the exterior finish of all buildings (not including windows and doors) must be masonry. For purposes of this paragraph, masonry materials include stone, cementitious simulated stone, brick, portland cement stucco, and cementitious siding. (ii) The use of no more than 15 percent of the following materials may be used on the exterior finish of a building: (aa) Pre-cast masonry (for trim and cornice elements only). (bb) Glass fiber reinforced fiber concrete and fiberglass reinforced plastic (for trim elements only). (cc) Metal (for beam lintels, trim elements, and ornamentation only). (dd) Split-faced concrete masonry unit (only for piers and foundation walls). (ee) Glass block (no closer than 30 inches to building corners). (ff) Fabric for awnings. (F) Public Art. Public art (including water features), approved in writing by the director of cultural affairs or the cultural affairs commission, must be provided. (G) Pedestrian Lighting. Pedestrian lighting (free-standing or wall-mounted) must be provided at one per 75 feet of frontage. (H) Underground Utilities. All utilities must be provided underground. (5) Maintenance. All pedestrian amenities must be maintained by the owner of the lot; if there is more than one owner, all owners are jointly and severally liable for maintenance. (g) No Waiver Permitted. No waiver of the minor street or streetscape provisions of this division is allowed through the subdivision process. (Ord. Nos. 29827, 30889)
Ask a question about Dallas law
Corpus searches the Dallas sections it holds and shows the ones that match, with their citations. Free, no sign-in.