Special factors.
14 C.F.R. § 29.619
in effectEffective (a) The special factors prescribed in §§ 29.621 through 29.625 apply to each part of the structure whose strength is—
(1) Uncertain;
(2) Likely to deteriorate in service before normal replacement; or
(3) Subject to appreciable variability due to—
(i) Uncertainties in manufacturing processes; or
(ii) Uncertainties in inspection methods.
(b) For each part of the rotorcraft to which §§ 29.621 through 29.625 apply, the factor of safety prescribed in § 29.303 must be multiplied by a special factor equal to—
(1) The applicable special factors prescribed in §§ 29.621 through 29.625; or
(2) Any other factor great enough to ensure that the probability of the part being understrength because of the uncertainties specified in paragraph (a) of this section is extremely remote.
Source: eCFRURL: https://www.ecfr.gov/api/versioner/v1/full/2024-07-01/title-14.xmlFetched: 7/26/2026
