For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 23-79 — Prohibited discharge standards

Charlotte City Code (Supp. No. 57: codified through Ordinance No. 10171, enacted June 22, 2026) · Charlotte City Code § 23-79

Corpus is an independent public-information project, not the official City of Charlotte website. Stable reference: corpuslaw.us/code/9dc27e7b-e35a-4319-b2da-cf074e5064f1

Sec. 23-79. - Prohibited discharge standards.

(a) General prohibitions. No user shall discharge or cause to be discharged into the POTW any pollutant or wastewater which causes interference or pass through. The general prohibitions in this section apply to all users of the POTW. (b) Specific prohibitions. No user shall discharge or cause to be discharged into the POTW the following: (1) Any pollutants which, either alone or by interaction with other pollutants, create a fire or explosive hazard in the POTW, including, but not limited to, waste streams with a closed cup flashpoint of less than 140 degrees Fahrenheit (60 degrees Celsius) using the test methods specified in 40 CFR 261.21. (2) Solid or viscous pollutants, fats, oils, or greases from animal or vegetable origin in amounts which may cause obstruction to the flow or other interference in the POTW. (3) Any wastewater having a pH less than 6.0 or greater than 12.0, or having any other corrosive property capable of causing damage or hazard to the POTW. (4) Pollutants, including oxygen demanding pollutants (cBOD 5 , BOD 5 , COD, etc.), released in a discharge at a flow volume, flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, will cause interference with the POTW. (5) Any noxious or malodorous liquids, gases or solids which, either singly or by interaction with other pollutants, are sufficient to create a public nuisance or hazard to life or are sufficient to prevent entry into the sewers for maintenance and repair. (6) Any pollutant released in a discharge at a flow volume, flow rate and/or pollutant concentration which, either singly or by interaction with other pollutants, may cause the POTWs effluent or any product of the POTW, such as residues, sludges or scums, to be unsuitable for reclamation and recycling or to interfere with the reclamation process. In no case shall a substance discharged to a POTW cause the POTW to be in noncompliance with applicable local, state or federal sludge use or disposal guidelines. (7) Any pollutant released in a discharge at a flow volume, flow rate and/or pollutant concentration, which will, either singly or by interaction with other pollutants, cause the POTW to violate any of its NPDES and/or state disposal system permits or the receiving water quality standards. (8) Any discharge having a temperature greater than 150 degrees Fahrenheit (66 degrees Celsius) or which will inhibit biological activity in the POTW treatment plant resulting in interference but, in no case, a discharge which causes the temperature at the introduction into the POTW treatment plant to exceed 40 degrees Celsius (104 degrees Fahrenheit). (9) Any pollutant which results in the presence of toxic gases, vapors, or fumes within the POTW in a quantity that may cause acute or chronic worker health and safety problems. (10) Any wastewater containing any radioactive wastes or isotopes except as specifically approved by CMUD in compliance with applicable state or federal regulations. (11) Any discharge at a flow rate which will cause interference with the POTW. (12) Any pump and haul waste, except at discharge points designated by CMUD in accordance with section 23-81 of this article. (13) Any waste stream which imparts color and passes through the POTW treatment plant, including, but not limited to, dye wastes and vegetable tanning solutions, which consequently imparts sufficient color to the POTW treatment plant's effluent, thereby violating any state or federal regulations pertaining to the effluent from the plant or the receiving water. (14) Stormwater, surface water, groundwater, artisan well water, roof runoff, subsurface drainage, and swimming pool drainage, unless specifically authorized by CMUD. (15) Any removed substances to include, but not be limited to, sludges, screening, or other residues from the pretreatment of wastewater. (16) Petroleum oil, nonbiodegradable cutting oil, synthetic oil, or products of mineral oil origin, in amounts that will cause interference or pass through. (17) Any indirect discharge which, alone or in combination with other wastewater, causes the treatment plant effluent to violate state water quality standards for toxic substances as described in 15 A NCAC 2B .0200. (18) Any pollutant that will emulsify grease or oil or cause grease or oil to solidify or become more viscous. (19) At no time shall two successive readings on an explosion hazard meter, at the point of discharge into the POTW, or at any point in the POTW, be neither more than five percent nor any single reading over ten percent of the lower explosive limit (LEL). (20) Any material that would be identified as hazardous waste according to 40 CFR Part 261 if not disposed of in a sewer, except as may be specifically authorized by CMUDD. (c) Processing and storage. Pollutants, substances or wastewaters prohibited by this section shall not be processed or stored in such a manner that they could be discharged to the POTW. When CMUD determines that a user(s) is contributing to the POTW, any of the above enumerated substances in such amounts which may cause or contribute to interference of POTW operation or pass through, CMUD shall: (1) Advise the user(s) of the potential impact of the contribution on the POTW in accordance with section 23-95; and (2) Take appropriate actions in accordance with article III, and the sections contained therein, for such user to protect the POTW from interference or pass through. (d) National categorical pretreatment standards. Users subject to categorical pretreatment standards are required to comply with applicable standards as set out in 40 CFR Chapter 1, Subchapter N, Parts 405—471: (1) Where a categorical pretreatment standard is expressed only in terms of either the mass or the concentration of a pollutant in wastewater, CMUD may impose equivalent concentration or mass limits in accordance with 40 CFR 403.6(c). (2) When wastewater subject to a categorical pretreatment standard is mixed with wastewater not regulated by the same standard, CMUD shall impose an alternate limit using the combined wastestream formula in 40 CFR 403.6(e). (3) A user may obtain a variance from a categorical pretreatment standard if the user can prove, pursuant to the procedural and substantive provisions in 40 CFR 403.13, that factors relating to its discharge are fundamentally different from the pretreatment standard. (4) A user may obtain a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. (e) Specific pollutant limitations. An industrial waste survey is required prior to a user discharging wastewater containing in excess of the following average discharge limits: CBOD | 250.0 | mg/l COD | 500.0 | mg/l TSS | 250.0 | mg/l NH 3 | 25.0 | mg/l Ammonia as N | 20.0 | mg/l Arsenic | 0.003 | mg/l Cadmium | 0.003 | mg/l Chromium | 0.05 | mg/l (total chromium) Copper | 0.061 | mg/l Cyanide | 0.015 | mg/l Lead | 0.049 | mg/l Mercury | 0.0003 | mg/l Nickel | 0.021 | mg/l Silver | 0.005 | mg/l Total Petroleum hydrocarbons | 100.0 | mg/l Zinc | 0.175 | mg/l Industrial waste survey information will be used to develop user-specific local limits when necessary to ensure that the POTWs maximum allowable headworks loading are not exceeded for particular pollutants of concern. User-specific local limits for appropriate pollutants of concern shall be included in wastewater permits. CMUD may impose mass based limits in addition to, or in place of concentration based limits.

(Ord. No. 5230, § 1(Exh. A), 10-28-2013)

Ask a question about Charlotte law

Corpus searches the Charlotte sections it holds and shows the ones that match, with their citations. Free, no sign-in.