Sec. 46.1-13. - Service for fire protection.
(a) The connection of the sprinkler system to the potable water supply shall be in accordance with the Uniform Statewide Building Code and this Code. Connection of a sprinkler system to the domestic water supply main where there is a standpipe is prohibited. All sprinkler systems shall have a connection, control valve, and drain and test connection directly connected to the city water main and separate from the domestic valve and water meter. Exception: Fire sprinklers installed in single-family detached dwellings and single-family townhouse dwellings up to a maximum of three (3) stories in accordance with the International Residential Code, chapter 29, and the Uniform Statewide Building Code (USBC). (b) Where city water is to be used for a sprinkler system for fire protection, or underground piping and fire hydrants on a dedicated fire line, a detector check valve and bypass meter shall be installed by the department of utilities at the curb line, at the expense of the applicant, in addition to the regular charge for connection to the main. The detector check valve shall be the same size as the line serving the facility and where fire hydrants are involved shall be no smaller than six (6) inches. Such installation shall be in accordance with provisions of the Uniform Statewide Building Code (USBC). (c) Any additional equipment installed by the department of utilities in connection with fire protection service attached to the city's water system, and associated costs of installation, shall be paid for by the owner or applicant at actual cost. (d) Where residential (except single-family detached dwellings and single-family townhouse dwellings up to a maximum of three (3) stories), institutional or commercial fire service is provided, a separate tap and fire service meter must be installed in addition to the water distribution system of the city. The water service line for all sprinkler systems and fire service lines shall be protected from backflow/backsiphonage in accordance with the provisions of chapter 11.1, article VII of this Code and as provided by the USBC. (e) Except for detached one- and two-family dwellings and townhouses up to a maximum of three (3) stories, the fire system will be designed by a licensed fire protection system company, with hydraulic calculations and required meter size submitted to the division of building safety and the department of utilities for review and approval. (f) Fire sprinkler systems for single-family detached dwellings and single-family townhouse dwellings up to a maximum of three (3) stories may be installed in accordance with chapter 29 of the International Residential Code, and the Uniform Statewide Building Code (USBC) and not require separate water tap, fire meter, and city check valve. However, a nontestable double check valve shall be installed. (g) Domestic service water lines for detached single-family dwellings and townhouse dwellings up to a maximum of three (3) stories and containing fire sprinklers must be installed in accordance with the International Residential Code, chapter 29, and the Uniform Statewide Building Code (USBC), part 1, and shall be provided with an adequately sized water meter based on design by a licensed plumbing contractor or a fire protection company. Hydraulic calculations, if required, shall be submitted to the division of building safety and department of utilities for review and approval. Designs submitted by licensed plumbers using prescriptive design methods according to the International Residential Code are permitted in lieu of hydraulic calculations. (h) Domestic plumbing systems containing fire sprinklers shall be multi-purpose systems and serviced by a water meter adequately sized to accommodate water demands in accordance with the International Residential Code. However, a nontestable double check valve shall be provided. (i) The owner/developer is responsible for paying the full actual cost of the fire system service tap and meter to the department of utilities. Prior to installation the owner/developer will deposit with the department of utilities an amount equal to the estimated cost. (j) In no instance shall any fire sprinkler system or fire service line be installed without the written consent of the department of utilities, and should it be found that any unauthorized connection has been made, or that water has been used from a sprinkler or fire service for any other purpose than extinguishing a fire, any domestic water service for that customer shall be turned off and not turned on until all water so used has been paid for.
(Ord. No. 41,100, § 2, 7-15-03; Ord. No. 43,836, § 2, 5-18-10)
Ask a question about Norfolk law
Corpus searches the Norfolk sections it holds and shows the ones that match, with their citations. Free, no sign-in.