550.1860. - Development standards for all permitted and conditional wind energy conversion systems.

In addition to the standards of sections 550.1820, 550.1830, 550.1840 and 550.1850 above, all wind energy conversion systems shall be subject to the following standards: (1) Maximum capacity. Wind energy conversion systems shall have a rated capacity of not more than one hundred (100) kilowatts. (2) SH Shoreland and MR Mississippi River Corridor Critical Area Overlay Districts. Freestanding and building mounted wind energy conversion systems shall be prohibited in the SH Shoreland and MR Mississippi River Corridor Critical Area Overlay Districts. (3) Encroachments and setbacks. a. Wind energy conversion systems shall comply with applicable regulations as established by the Federal Aviation Administration. b. Wind energy conversion systems shall comply with the minimum yard requirements of the district in which they are located. c. No part of any wind energy conversion system shall extend across or over any part of a public right-of-way. (4) Compatibility with nearby properties. Wind energy conversion systems shall utilize building materials, colors and textures that are compatible with the existing principal structure and that effectively blend the system facilities into the surrounding setting and environment to the greatest extent possible. Rotor blades shall be non-metallic to prevent communication signal interference. Metal towers shall be constructed of, or treated with, corrosive resistant material. Outside of the production districts, unpainted, galvanized metal, or similar towers shall be prohibited, unless a self-weathering tower is determined to be more compatible with the surrounding area. (5) Controls and brakes. All systems shall contain an internal governor or braking device which engages at wind speeds in excess of forty (40) miles per hour and minimizes the potential for wind damage to the equipment. (6) Signage. Advertising or identification of any kind on wind energy conversion systems shall be prohibited, except for applicable warning and equipment information signage required by the manufacturer or by federal, state or local regulations. (7) Lighting. Wind energy conversion systems shall not be illuminated by artificial means, except where the illumination is specifically required by the Federal Aviation Administration or other federal, state or local regulations. (8) Noise. Wind energy conversion systems shall comply with the standards governing noise contained in Chapter 389 of the Minneapolis Code of Ordinances, Noise, and with all other applicable regulations. (9) Heritage Preservation Ordinance compliance. Wind energy conversion systems proposed for any locally designated historic structures or locally designated historic districts shall be subject to all requirements of the city's Heritage Preservation Ordinance. (10) Maintenance required. All wind energy conversion systems shall be kept in good repair and free from rust, damaged supports, framework or other components.

Ask a question about Minneapolis law

Corpus searches the Minneapolis sections it holds and shows the ones that match, with their citations. Free, no sign-in.