§ 254-27. - Heating facilities; duty to supply heat.
A. Residential.
(1) Supplied heating facilities.
(a) Every dwelling unit shall contain supplied heating facilities which are installed properly, are maintained in safe and good working condition and are capable of maintaining a minimum inside temperature of at least 68 degrees Fahrenheit between the hours of 6:00 a.m. to 11:00 p.m. and at least 65 degrees Fahrenheit between the hours of 11:00 p.m. to 6:00 a.m. whenever the outside temperature falls below 55 degrees Fahrenheit from October 1 of each year to the next succeeding May 1. At times other than those specified interior units of dwelling space shall be maintained at least at 55 degrees Fahrenheit whenever the outside temperature falls below 40 degrees Fahrenheit. The temperature shall be read at a height of 30 inches above floor level at the center of the room.
(b) These facilities may be supplied by the owner or the tenant based on the rental agreement.
(c) Heating facilities in properties containing four units or more shall be inspected biennially, once every two years. Such inspection shall be by a licensed plumber, licensed heating contractor or an employee of a gas utility company certified as qualified to make such inspections. Each inspection shall include such tests and visual inspections as are necessary to determine whether there is any gas leak at the premises, whether there is any defective equipment and whether there are unsafe conditions or unsafe equipment present. Such inspection shall be in addition to any inspection or maintenance requirements set forth by the State of New Jersey.
(d) The person, firm or corporation making the inspection and the owner or a person in charge of the premises shall each keep a copy of the inspection record until the next biennial inspection. The owner or person in charge of the premises shall exhibit a copy of the inspection report to any city inspector on demand.
(e) If any unsafe conditions or unsafe equipment are found, the inspector shall apply a red tag in a clearly visible location at or near the heater, furnace or thermostat, stating substantially as follows:
WARNING: This equipment is unsafe to use. Do not attempt to light or turn on this equipment until complete repairs have been made and this warning tag has been removed by an authorized inspector. For information telephone (telephone number to be supplied.)
(2) Where central heating required. Decentralized heating systems now in use may be continued in use in accordance with Subsection A(1)(a) and (b) above, provided that the above mentioned decentralized heating systems conform with all other applicable codes and standards. [6]
(3) Facilities required in lieu of central heating. All dwelling units and rooming units not having central heating shall be permitted to be heated (in the interim) by supplied space heaters.
(4) Every space heater shall comply with all of the following requirements:
(a) Every space heater burning gaseous, liquid or solid fuels shall be permanently installed.
(b) Every space heater burning gaseous, liquid or solid fuels shall be properly vented to a chimney, duct or flue leading to outdoor space.
(c) Every space heater shall have a permanently affixed, fire resistant panel beneath it.
(d) Every space heater located within two (2) feet of a wall shall be equipped with insulation sufficient to prevent overheating of the wall.
(e) Every space heater smoke pipe shall be equipped with guards, properly constructed of nonflammable material, at any point where the pipe goes through a ceiling, partition or wall.
(f) Every space heater shall comply with all the requirements of Chapter 131, Uniform Construction Codes, and electrical space heaters must meet the standards set by the Middle Department Association of Fire Underwriters. [7]
(g) The use of any unvented space heater burning gaseous, liquid or solid fuels is prohibited.
(h) Any merchant selling unvented space heaters burning gaseous, liquid or solid fuels must display a sign, within three feet of the space heater display and in full view of customers, bearing the words "Warning: the City of Jersey City Fire Prevention Bureau warns that the use of unvented space heaters burning gaseous, liquid or solid fuels is hazardous, and the use of these heaters is banned according to § 254-27A(4) of the Jersey City Code." The letters used on this sign must be no smaller than two inches in height and one inch in width.
(5) The use of portable heating equipment employing flame and solid, liquid or gaseous fuels is prohibited.
(6) The use of portable electric space heaters in bathrooms or water closet compartments is prohibited.
(7) When the owner or manager is required to supply heat.
(a) From October 1 to May 1, every dwelling unit, room unit, bathroom and water closet compartment shall be supplied with sufficient heat to maintain therein a minimum temperature of 68 degrees Fahrenheit between the hours of 6:00 a.m. and 11:00 p.m. and 65 degrees Fahrenheit between the hours of 11:00 p.m. and 6:00 a.m. whenever the temperature falls below 55 degrees Fahrenheit.
(b) From May 1 to October 1, every dwelling unit, rooming unit, bathroom and water closet compartment shall be supplied with sufficient heat to maintain therein a minimum temperature of see 55 degrees Fahrenheit whenever the outside temperature falls below 40 degrees Fahrenheit.
(c) Whenever a dwelling is heated by means of a furnace, boiler or other apparatus under the control of the owner or manager of the dwelling, such owner or manager, in the absence of a written contract to the contrary, shall be deemed to have contracted, undertaken or bound himself to furnish heat in accordance with the provisions of Subsection A(1) through (7) of this section to every dwelling unit and rooming unit which contains radiators, furnace heat duct outlets or other heating apparatus outlets.
B. Nonresidential.
(1) Supplied heating facilities. Every business, commercial, governmental, industrial and institutional building shall contain supplied heating facilities which are properly installed, are maintained in safe and good working condition and are capable of maintaining a minimum inside temperature of 70 degrees Fahrenheit in all occupiable rooms, bathrooms and water closet compartments when the outside temperature is at or above zero degrees Fahrenheit. The temperature shall be read at a height of 30 inches above the floor level at the center of the room. Occupiable rooms located in buildings where it is not feasible to heat them to a temperature of 70 degrees Fahrenheit, because of the nature of the business, are exempted from this requirement.
(2) Portable heating equipment prohibition. The use of portable heating equipment employing flame and solid, liquid or gaseous fuel is prohibited.
(3) When the owner or manager is required to supply heat.
(a) From October 1 to May 1, every occupiable room, bathroom and water closet compartment shall be supplied with sufficient heat to maintain therein a minimum temperature of 70 degrees Fahrenheit during whatever hours of each day the building is open for use.
(b) From May 1 to October 1, every occupiable room, bathroom and water closet compartment shall be supplied with sufficient heat to maintain therein a minimum temperature of 70 degrees Fahrenheit whenever the outside temperature falls below 55 degrees Fahrenheit between the hours of 6:00 a.m. and 11:00 p.m.
(c) Whenever a nonresidential building is heated by means of a furnace, boiler or other apparatus under the control of the owner or operator of the building, such owner or operator, in the absence of a written contract to the contrary, shall be deemed to have contracted, undertaken or bound himself to furnish heat in accordance with the provisions of Subsection B(1) through (3) of this section to every occupiable room, bathroom and water closet compartment which contains radiators, furnace heat duct outlets or other heating apparatus outlets.
C. In enforcing this section the Municipal Judges shall utilize the form of summons issued by the administrative office of the court. The summons may be served upon any persons, corporations, business firms and/or partnerships violating this section by inspectors or properly authorized employees of the Division of Construction Code Official. The Judges are further authorized by rule to provide that violators may sign or execute on the back of the summons a written plea of "guilty" and the submission of a fine for offenses of this section. The fine for any offense of this section shall be as provided in Chapter 1, General Provisions, § 1-25.
[Amended 9-22-1983 by Ord. No. MC-459; 9-25-1986 by Ord. No. C-303; 10-23-1986 by Ord. No. C-322; 8-18-1988 by Ord. No. C-788; 12-16-2020 by Ord. No. 20-102] [Amended 10-28-1980 by Ord. No. S-510; 6-14-1995 by Ord. No. 95-050; 8-13-1997 by Ord. No. 97-052]