§ 26-323 — Placement and operation of mobile food units
Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Code of Ordinances § 26-323
Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/a039ccac-5dd7-474c-b499-ac8eb3d18c58
Sec. 26-323. - Placement and operation of mobile food units.
(a) A mobile food unit operator shall not: (1) Sell anything other than food and non-alcoholic beverages and items incidental to the product and its consumption: (2) Set up more than one covered ten by ten table to provide condiments to patrons; (3) Play any music, sound effect or noise that is audible outside of the vehicle; (4) Place or utilize any signage that is not permanently affixed to the mobile food unit; (5) Fail to provide receptacles and properly dispose of all trash, refuse, compost and garbage that is generated by the use; (6) Cause any liquid wastes to be discharged from the mobile food unit; (7) Locate a mobile food unit within 100 feet of a single-family or two-family residential use as measured from its property line or on the same property as an existing restaurant unless the owner of that restaurant owns the mobile food unit. (b) The following are requirements for the City of Sandy Springs Fire Department. Each mobile food unit shall be checked for compliance at licensing and may be inspected annually. (1) A fire extinguishing system designed for cooking operations shall be installed in accordance with NFPA 17A and UL 300 to cover cooking equipment which requires a mechanical exhaust ventilation system. The extinguishing system shall be serviced and tagged by a state licensed fire extinguisher business every six months. (2) Mechanical exhaust ventilation system equipment shall be provided over all cooking equipment as required to affectively remove cooking odors, smoke, steam, grease, heat and vapors. (3) All mechanical exhaust ventilation equipment shall be commercial and installed and maintained in accordance with NFPA 96 120-3-3 and any adopted local fire and/or building codes. (4) A fire extinguisher is required for protecting Class ABC hazards and shall have at least one 2A20BC extinguisher mounted in an accessible location. The ABC extinguisher shall be serviced and tagged by a state licensed fire extinguisher business every 12 months or within two months of an application for an annual permit. (5) A fire extinguisher is required for combating grease fires and shall have at least one K-Class fire extinguisher mounted in an accessible location. The K-Class extinguisher shall be serviced and tagged by a state licensed fire extinguisher business every 12 months or within two months of an application for an annual permit. (6) "NO SMOKING" signs shall be posted. (7) If a flammable gas tank in used inside the vehicle, there must be at least two ventilation openings venting to the outside. One located near the cylinder valve and one must be located at floor level. (8) Tanks must be properly secured to a rigid structure. (9) All supply hose for the tank shall be rubber, located off the floor, protected from physical damage and stamped "APPROVED FOR LP GAS" or "APPROVED FOR NATURAL GAS". (10) The main shut off for gas must be marked. (11) Extension cords shall not be substituted for permanent wiring. Extension cords shall be used only with portable appliances. (12) Ground fault circuit-interrupter protection shall be provided for receptacles located near sink or water basin
(Ord. No. 2017-10-22, § I, 10-17-2017)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.
