§ 30-53 — Specific standards
Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton City Code § 30-53
Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/a09ecaa4-60fb-4106-a1a7-a08fbf189f86
Sec. 30-53. - Specific standards.
(a) Residential construction. New construction or substantial improvement of any residential structure within the floodway fringe or within two hundred (200) feet of the floodplain or SFHA boundary shall have the lowest floor, including basement, elevated at or above the minimum building elevation. A registered professional engineer, architect, or land surveyor shall submit a FEMA Elevation Certification to the city engineer, in accordance with section 30-34(a)(1), that the standard of this subsection is met. (b) Nonresidential construction. New construction or substantial improvement of a commercial, industrial, or other nonresidential structure within the floodway fringe or within two hundred (200) feet of the floodplain or SFHA boundary shall have the lowest floor, including any basement, elevated at or above the minimum building elevation, or this construction, together with attendant utility and sanitary facilities, shall be floodproofed so that the structure is watertight to an elevation at or above the minimum building elevation with walls substantially impermeable to the passage of water and structural components have the capability of resisting hydrostatic and hydrodynamic loads and the effects of buoyancy. If the flood insurance study does not include the property, the required one-hundred-year water surface elevations shall be based on ultimate development watershed conditions. A registered professional engineer, architect, or land surveyor shall submit a certification to the city engineer, in accordance with section 30-34(a)(1), that the requirements of this subsection are met. (c) Manufactured homes. (1) All manufactured homes to be placed or substantially improved within zone A on a community's FHBM or FIRM shall be installed using methods and practices which minimize flood damage. For purposes of this requirement, manufactured homes must be elevated to thirty (30) inches above an estimate of the one-hundred-year water surface elevation as determined by the mapped extent of the A zone and anchored to resist flotation. Methods of anchoring may include but are not limited to use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. (2) All manufactured homes to be placed or substantially improved within zones A1-30, AH, AE, and Shaded X shall be elevated on a permanent foundation so that the lowest floor of the manufactured home is at least thirty (30) inches above the base flood elevation found in the current flood insurance study, or, if no flood insurance study is available, eighteen (18) inches above the one-hundred-year water surface elevations, as determined using fully developed watershed conditions, and shall be securely anchored to an adequately anchored foundation in accordance with all tie-down requirements imposed by state law or city ordinance. (3) All manufactured homes not otherwise subject to the requirements of subsection 30-53(c)(1) or (c)(2) shall, if placed or substantially improved on sites within an existing manufactured home park or subdivision located within zones A1-30, AH, or AE of the FIRM, be elevated so that either: (i) The lowest floor of the manufactured home is elevated thirty (30) inches above the base flood elevation found in the current flood insurance study, or, if no flood insurance study is available, eighteen (18) inches above the one-hundred-year water surface elevations, as determined using fully developed watershed conditions; or (ii) The manufactured home chassis is supported by reinforced piers, or other foundation elements of equal or greater strength, with the lowest floor of the manufactured home elevated at least thirty-six (36) inches above grade, and securely anchored to a foundation system sufficient to resist flotation, collapse, and lateral movement in accordance with all tie-down requirements imposed by state law or city ordinance. (d) Recreational vehicles. All recreational vehicles placed on sites within zones A1-30, AH, and AE on the community's FIRM shall either: (1) Be on the site for fewer than one hundred eighty (180) consecutive days; (2) Be fully licensed and ready for highway use; or (3) Meet the permit requirements of section 30-34(a) and the elevation and anchoring requirements specified for "manufactured homes" in subsection 30-53(c). A recreational vehicle is ready for highway use if it is on its wheels or jacking system and is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions.
(Ord. No. 22-2064, § 2, 10-18-22)
Ask a question about Denton law
Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.