Car wash facility.
Cape Coral Land Development Code § 5.11.17
in effectSection 5.11.17. - Car wash facility.
In addition to other provisions of the Land Development Code, Car wash facilities shall meet all of the following conditions:
A. Applicability: This section shall apply to all car wash facilities as defined in LDC Section 11.2, except as noted below.
1. Exceptions:
a. Car wash facilities that are accessory to a primary use, where the accessory use area occupies no more than 20% of the overall site area, and which are fully integrated into the primary use structure or area are exempt from this section.
b. Car wash facilities that are accessory to a primary use classified as light vehicle sales on sites where the establishment has a minimum developed area of five acres.
c. Temporary outdoor car wash facilities associated with a non-profit, religious function, or governmental organization are exempt from this section provided that the use is temporary and no automated equipment or systems are utilized.
B. Locational Requirements: All facilities shall conform to the following location standards:
1. There shall be a minimum separation distance of one mile (5,280 feet) between parcels occupied, or to be occupied, by a car wash facility. Such a distance shall be measured by the shortest straight-line measurement between the nearest points of the applicable parcels.
2. Car Wash facilities shall only be permitted on those parcels which have primary frontage on roadways with the following City of Cape Coral Functional Classifications: Minor Collector; Major Collector; Minor Arterial; Major Arterial; and Principal Arterial. Functional roadway classifications shall be determined by the City of Cape Coral and all classifications shall be made available to the public. Primary frontage is defined as a minimum linear frontage that is equal to or exceeds 75% of overall linear property frontage along all public rights-of-way.
3. Parcels associated with car wash facilities shall not be permitted within 500 feet of any major intersection involving any combination of collector and/or arterial streets. This distance shall be measured in the shortest straight-line measurement between the centerline of the intersected rights-of-ways and the nearest point of the parcel.
C. Enclosure Required: All washing uses, facilities, and equipment shall be within an enclosed building, including those systems and equipment which is ancillary or accessory to the operation of the facility except as noted below.
1. Exception: Centrally designed vacuum facilities may have exposed apertures, nozzles, and piping directly associated with the servicing of a vehicle, provided all central equipment, including pumps, turbines, separators, filters, and manifolds, are completely enclosed within a building and that the noise generated from the exposed equipment is mitigated to the greatest extent possible.
D. Residential Adjacency: The following regulations shall apply when a car wash facility is located directly adjacent to a site with residential zoning or a residential use, either through directly abutting property line(s) or being separated by an alleyway, canal, or local roadway:
1. All uses and equipment shall be oriented away from the adjacent residential zoning or uses. Where such orientation would provide an undue hardship to the implementation of the uses on the site, additional screening shall be provided to mitigate the visual impact of the facility. Such screening may be comprised of additional vegetative hedging, living green walls, or an architecturally interesting vertical barrier and implemented as directed through conditions of approval applied by the City of Cape Coral.
2. The facility shall be designed so as to provide an increased buffered separation along all directly abutting residential property lines. The buffer shall conform to all applicable standards and regulations contained in LDC Article 5, Section 5. The buffer width shall be in excess of 150% the required buffer width specified in Table 5.5.13.B and shall include the utilization of either a six-foot tall bermed earth feature or an eight-foot tall separation wall. The buffer area shall provide plantings of 150% or more of the required amount per LDC Section 5.5.13, for all plantings. The wall shall meet all applicable standards and requirements as specified per LDC Section 5.5.13.C.5.g.
a. Where the facility abuts a mixed-use zoning district, or mixed-use site, which includes any form of residential uses and no buffer requirement is specified in table 5.5.13.B, the facility shall provide a buffer with a minimum width of twenty feet. Landscaping within the buffer shall be provided at the highest intensity specified per table 5.5.13.C abutting the R-1 district. The buffer area shall be designed to meet all other criteria listed in Section 5.11.17.D.2.
b. Where a canal or road right-of-way separates two property lines requiring the buffer separation as specified in this section, the buffering requirements shall also be applied along the property lines adjacent to the right-of-way.
E. Landscape Screening: Specifically designed landscape screenings and treatments shall be provided to mitigate the visual impact of exterior equipment and utilities, exterior vacuum apertures and equipment, and openings in enclosed facility spaces from all public rights-of-way. The screening shall be designed in such a way that the internal and external uses of the facility are screened to the greatest extent possible when viewed from the rights-of-way and shall be approved through conditions of approval applied by the City of Cape Coral.
F. Outdoor Storage and Display: The outdoor storage and display of merchandise, parts and supplies shall be prohibited. All materials shall be located completely within an enclosed building.
G. Hours of Operation: For facilities which are located adjacent to residentially zoned districts, the hours of operation for the facility shall be limited through conditions of approval applied by the City of Cape Coral.
H. Noise Mitigation: The use of exterior loudspeakers, paging equipment or noise makers, is prohibited.
I. Water Recycling: The facility shall be designed and constructed to comply with National Pollutant Discharge Elimination System (NPDES) requirements for car washes to prevent creating and carrying off the premises, of airborne particles of water, chemicals, and dust. No wash-water runoff generated by the facility may be conveyed off site into stormwater or wastewater systems without pretreatment. Car-wash equipment shall use a 90% water recycling system, utilizing 100% of wastewater.
J. Prohibitions: The following shall be prohibited on site:
1. Exterior detailing and waxing which utilizes any type of machines or equipment is prohibited.
K. View Corridor Protection: Where a facility is developed adjacent to a residential site or use and has any frontage along a canal, or canal right-of-way, the facility shall be so designed to adequately protect visual corridors to the canal way for adjacent residential uses. Design and implementation shall be approved through conditions of approval applied by the City of Cape Coral.
(Ord. 66-24, § 2, 10-16-2024)
Source: City of Cape Coral, Florida, Code of Ordinances, City Charter and Land Development Code (Municode Library, library.municode.com)URL: https://library.municode.com/fl/cape_coral/codes/code_of_ordinances?nodeId=ART5DEST_CH11COUS_S5.11.17CAWAFAFetched: 11/4/2026