For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.40.490 — Amend CBC Section 2304.10.2—Fastener requirements

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.40.490

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/a2194bba-6ae3-484d-b1e3-b3014f3c8f79

18.40.490 - Amend CBC Section 2304.10.2—Fastener requirements.

Section 2304.10.2 of the California Building Code is amended to read as follows: 2304.10.2 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.2. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F. Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the Building Official.

(ORD-25-0019 § 1(Exh. A), 2025)