For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 4-26 — Adoption

Code of Ordinances, City of Southaven, Mississippi (Supp. No. 70: codified through Resolution of June 2, 2026) · Southaven Code of Ordinances § 4-26

Corpus is an independent public-information project, not the official City of Southaven website. Stable reference: corpuslaw.us/code/a2bb37ad-66b1-4330-b23c-e0555f87fa5e

Sec. 4-26. - Adoption.

(a) The following codes are hereby adopted and enforced by the city as set forth in this subsection (a). (1) 2024 International Residential Code with Appendices BD, BF, BG, CA, CB, CE, CF. (2) 2012 International Energy Code or option to choose a more current edition. (3) 2024 International Fire Code. (4) 2024 International Plumbing Code with Appendices A, B, C, D, E. (5) 2024 International Mechanical Code with Appendices A, B. (6) 2024 International Fuel Gas Code. (7) 2023 International Electrical Code as a reference of the 2024 International Building Code but not including Section 203.67 of the 2023 International Electrical Code. (8) 2024 Swimming Pool and Spa Code. (9) 2024 International Existing Building Code. (b) The 2023 International Electrical Code shall be revised as set forth in this section. Arc fault breakers shall be required in all occupied areas of the home and ground-fault interrupters shall be required in all rooms that might have a wet condition. There shall be a dedicated single receptacle for the garage door and a single dedicated receptacle may be provided in the garage for a freezer or refrigerator. All other receptacles within the garage must be ground faults. GFCIs shall not be required for the following specific appliances electric ranges, wall mounted ovens, counter mounted appliances, clothes dryers, and microwaves. At least one (1) receptacle shall be installed at each island and peninsula countertop space with a long dimension of twenty-four (24) inches or greater and short dimension of twelve (12) inches or greater. A peninsula countertop is measured from the connected perpendicular wall. All ceiling boxes where ceiling fans might be installed at some point in the future must be provided with ceiling fan boxes with proper support. (c) The 2024 International Residential Code shall be revised as set forth in this section. Hold-downs are to be provided in all corners, at a minimum, to hold the walls to the slab and exterior walls along with interior load-bearing walls must be anchored with bolts and three (3) inch by three (3) inch washers to attach those walls to the slab. The 18-gauge steel strapping shall be installed at 48-inch centers across floor joist spaces to walls to connect stories together and installed on 48-inch centers to connect roof raters to the top plates of walls to connect the roof to the walls. 18-gauge steel clips shall provide at window and door headers to connect support the openings in the walls and 20-gauge steel plate connectors must be used to connect king or jack studs to wall plates top and bottom. Residential plans shall include all of the details necessary to determine structural stability and wind and seismic devices shall be included. Brace walls four (4) feet in width shall be provided within ten (10) feet of all corners and within twenty (20) feet of each other; however, where this requirement is not able to be met or when more than one (1) story, prefabricated panels shall be used, and these shall be shown on the plans. (d) The 2024 International Building Code shall be revised as set forth in this section. Section 403.2 Separate Facilities Exception #6 shall be revised by deleting the provision noting "that separate toilet facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by all persons regardless of sex and privacy is provided for water closets in accordance with Section 405.3.4 and for urinals in accordance with Section 405.3.5." However, the exceptions that allow single user facilities based upon occupant load and occupancy class shall remain. There shall be separate facilities for males and females.

(Ord. No. 6, § 1, 6-15-83; Ord. of 2-17-87(2), § I; Ord. of 4-16-96(1), § I; Ord. of 8-15-00; Amd. of 4-20-04(2), § 1; Amd. of 12-4-07, § 1; Res. of 8-5-14(1), § 1; Res. of 4-7-15; Res. of 9-15-20(1), § 1; Res. of 10-7-25(1), §§ 1—4, eff. 1-1-26)

Ask a question about Southaven law

Corpus searches the Southaven sections it holds and shows the ones that match, with their citations. Free, no sign-in.