§ 14.04.050 — Section 1505.1 of the 2025 California Building Code is amended to read as follows

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.050

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/a4fda40c-3230-4da1-8fed-fb3bc7071fd3

14.04.050 - Section 1505.1 of the 2025 California Building Code is amended to read as follows.

[BF] 1505.1 General. Fire classification of roof assemblies shall be in accordance with Section 1505. The minimum fire classification of roof assemblies installed on buildings shall comply with Table 1505.1 based on type of construction of the building. Class A and B roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E108 or UL 790. In addition, fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with Table 1505.1 based on the type of construction of the building. All roof assemblies and roof coverings shall be of not less than Class B. No wood roof covering material shall be installed on any structure located in the very high, high and moderate fire hazard severity zones as identified by the Pasadena Fire Department. Exception 1: Skylights and sloped glazing that comply with Chapter 24 or Section 2610. Installation of skylights of plastic material shall meet the requirements of the very high and high fire hazard severity zones. Exception 2: In the moderate fire hazard severity zone, the fire code official may, upon a showing of good cause and necessity, approve the use of fire resistive wood as part of Class A listed assemblies, and may require additional mitigation as warranted, for the repair or maintenance of existing structures. [BF] TABLE 1505.1—MINIMUM ROOF ASSEMBLY CLASSIFICATION FOR TYPES OF CONSTRUCTION a, IA | IB | IIA | IIB | IIIA | IIIB | IV | VA | VB B | B | B | B c | B | B c | B | B | B c For SI: 1 foot = 304.8 mm, 1 square foot = 0.0929 m 2 . a. Unless otherwise required in accordance with the California Wildland-Urban Interface Code or due to the location of the building within a fire district in accordance with Appendix D. c. Buildings that are not more than two stories above grade plane and having not more than 6,000 square feet of projected roof area and where there is a minimum 10-foot fire-separation distance from the leading edge of the roof to a lot line on all sides of the building, except for street fronts or public ways and is not located in a fire hazard severity zones, shall be permitted to have roofs of No. 1 cedar or redwood shakes and No. 1 shingles constructed in accordance with Section 1505.7.

(Ord. No. 7461, § 5, 11-10-2025)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.