§ 5.8.5 — Design standards
Code of Ordinances, City of Tupelo, Mississippi (Supp. No. 15: codified through Ordinance of March 5, 2024 and Ordinance of June 4, 2024) · Tupelo Development Code § 5.8.5
Corpus is an independent public-information project, not the official City of Tupelo website. Stable reference: corpuslaw.us/code/a50f63a9-f40a-4d6b-ada3-70f0c337117c
5.8.5. - Design standards.
(1) The Design Review Committee shall be guided by the standards for traditional housing construction (Section 6.4.3) as modified below, by the standards for infill construction (Section 6.10), by the compatibility checklist procedure (Section 12.4.5), and by reference to existing architectural features of the immediate vicinity and of the overlay district generally. (2) Traditional housing standards modifications. (a) Size limitations. Minimum square foot requirements for each residence shall be at a minimum 1,000 square feet heated and cooled living area. (b) Main entrance. This standard is not modified. (c) Porches. A porch shall be provided for each dwelling unit of at least seven feet six inches in depth and 12 feet in length. Variances may be approved if the overall square footage exceeds 90 square feet. Porch columns shall be a minimum of six inches wide, shall be square or rectangular in section, and may not be wrought iron or other material that is not solidly opaque. Other standards for porches are not modified. (d) Covered balconies. This standard is not modified. Alternative roof materials may be considered. (e) Garages and Carports: a. Front, side or rear of house is permitted. b. If visible from the street, carport columns must be of similar size and material to porch columns. Other standards for garages are not modified. c. If front facing, cannot be more than 30 percent of the front-facing linear dimension. d. Roofs shall be the same material of the principal structure. (f) Roofs. a. Slope. Principal structures must have a roof that is sloped, with at least four units of vertical rise to 12 units of horizontal run, and not exceeding 12 units of vertical rise to 12 units of vertical run. b. Architectural features. The roof of a principal structure shall include at least one of the following architectural details: i. A gable end, or gabled end of a roof projection, facing the street; or ii. An offset section either set back from the front facade or with a lower roof line than the main section of the structure. iii. Roof eaves must project from the building wall on at least the front and side elevations, and such projections may not exceed 12 inches. iv. No hip roof on front or sides. c. Materials. Roofs shall be asphalt shingle. No metal roofs are permitted for the principal structure. d. Decorative metal covers may be permitted as awnings, over porches or decks. These must be submitted for approval by Design Review Committee. e. Other standards for roofs are not modified. (g) Foundation. a. Height. Finished floor height, or ground level of the first floor, shall be elevated a minimum of 14 inches and a maximum of 18 inches above finished grade, or pad height, to allow for a minimum of two steps front entry onto the first floor. Finished floor height requirements do not apply to elevations at the structures side or rear. b. Fill to achieve pad height should not be utilized without drainage review and should not exceed more than 12 inches above center line or the point of storm water discharge from the lot. c. Finish material must be brick, stone or other finished surface material. d. Other standards for foundation are not modified. (h) Exterior finish materials. a. Allowable materials are stone, brick, plaster, EIFS, cedar shakes, wood siding such as Hardie board six inches or less ship lap or equivalent, b. Other standards for Exterior Finish Materials are not modified. (i) Windows and entryways. At least 25 percent of the area of a street-facing facade must include windows or main entryways. Each window must be square or vertical and muntins must be in a vertical proportion. A horizontal window opening may be created by grouping two or more vertical windows. Other standards for windows and entryways are not modified. a. Garage, storage building, pool house, or accessory structure of any type: Must have the same roofing and outside wall materials as those used in the principal structure. b. Fences: All fences and/or screen walls are to be made of wood, masonry, stucco or ornamental metal material or landscape material. No chain link fences visible from the street or adjacent properties shall be permitted. i. Fences located in the front yard shall be no more than 36 inches high and must be able to see thru 50 percent of the height. ii. Location: 1. No fences shall be erected nearer to a street than ten feet. Variances may be considered. (3) All properties and the dwellings constructed thereon shall be used for single-family residential purposes. (4) No lot can be subdivided and sold in part except as located on the plat of said subdivision previously filed in the Office of Lee County Chancery Clerk. Any combination of platted lots must be approved by the Designed Review Committee. (5) The Design Review Committee may prepare and propose additional written standards for adoption through amendment of this section.
(Ord. of 10-4-2022(25), § 2)
Ask a question about Tupelo law
Corpus searches the Tupelo sections it holds and shows the ones that match, with their citations. Free, no sign-in.