25.10.310 - Calculations and measurements.

A. All calculations and measurements for the purposes of determining radiofrequency radiation levels shall be carried out as follows: 1. Ambient radiofrequency radiation levels shall be measured using equipment generally recognized by the Environmental Protection Agency (EPA), National Council on Radiation Protection and Measurements (NCRP), American National Standards Institute (ANSI), National Bureau of Standards (NBS), or similarly qualified organization as suitable for measuring radiofrequency radiation at frequencies and power levels of the proposed and existing sources of radiofrequency radiation and calibrated as recommended by the manufacturer in accord with methods used by the National Bureau of Standards. 2. The effect of contributing individual sources of radiofrequency radiation within the frequency range of a broadband measuring instrument may be specified by separate measurement of these sources using a narrow-band measuring instrument. All sources in the resonant frequency range (thirty (30) MHz to three hundred (300) MHz) shall be added to show the total power density. 3. Radiofrequency radiation measurements shall be made when radiofrequency radiation levels are expected to be highest due to operating and environmental conditions. 4. Radiofrequency radiation measurements shall be made following the spatial and time averaging procedures as recommended by the American National Standard Institute (ANSI) publication: American National Standard Recommended Practices for the Measurement of Potentially Hazardous Electromagnetic Fields-Radiofrequency and Microwave. 5. For frequencies in the range of 0.1 to thirty (30) MHz, radiofrequency radiation levels shall be determined by measurement of both the electric and magnetic field strengths (or their squares) or the equivalent plane-wave free-space power densities associated with the electric and magnetic fields. B. Radiofrequency radiation calculations shall be consistent with Office of Science and Technology Bulletin No. 65 of the Federal Communications Commission, or other engineering practices recognized by the Environmental Protection Agency, National Council on Radiation Protection and Measurements, American National Standards Institute, National Bureau of Standards or similarly qualified organization. C. Measurements and calculations shall be certified by the person responsible for them and shall be accompanied by an explanation of the protocol, methods, equipment, and assumptions used. The certification shall include an affidavit stating the qualifications of the person responsible for the measurements and calculations. The Administrator shall approve the measurements and calculations.

(Ord. 116057, § (part), 1992)

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.