Sec. 27-211.6. - Development Standards for Commercial, Mixed-Use, or other Non-Residential (SH-CG and SH-CI) development.
(a) Building placement, form, and layout standards: all development shall comply with development standards set forth below. Single-family detached residential shall adhere to the development standards of SH-RS. Semi-detached, attached, and two-family residential shall adhere to the development standards of SHRS-A multi-family residential shall adhere to the development standards of SH-RM. Graphic 211.6a [image omitted; see the official code] KEY (SH-CG and SH-CI, as specified below): Table 211.6a See also Sec. 27-43 Definitions | PB: Principal building AB: Accessory building BTL: Build-to-line | F: Front SS: Side (street) SI: Side (Interior) R: Rear | FB: Front Building Form SSB: Side (street) Building Form | LW: Lot Width LA: Lot Area SF: Square Feet min: minimum Building Placement (PB) | Building Placement (AB) BTL [1, 3] | Setback [4] F | 10′ | F | 10′ SS | 10′ | SS | 10′ Setback [2, 4] | Setback [4] SI | 0′ | SI | 0′ R | 15′ | R | 15′ Building Form [7] | Building Form FB | 50% min [5] | FB | N/A SSB | 25% min [5] | SSB | N/A Lot Configuration [6] Lot Width | 75′ min Lot Area | 7500 SF min [8] Notes: [1] Build-to-line: required line/location at which the building wall shall be placed. [2] Canopies, awnings, arcades, trellises, pergolas, and other architecturally integrated façade features may be placed at zero (0) feet setback. See Map SH-25.2 for additional encroachment allowances, when applicable. [3] Building façades along front BTL must have functioning ground floor entrance. Rear-only facing buildings are prohibited. [4] Setback: the line/location that sets the minimum distance at which the building wall may be placed. [5] Minimum % of building façade (ground floor) shall be built at required BTL. [6] A lot of record established prior to July 1, 2010, shall be allowed to develop, subject to the regulations set forth in this article. [7] Drive-in windows and any associated overhangs/canopies shall be setback a minimum of 50 feet from the principal street (Front). [8] For those properties within designated nodes per the Greater Seminole Heights Vision Plan and the Tampa Comprehensive Plan, refer to Sec. 27-211.15. (b) Use and general building standards: all development shall comply with development standards set forth below: Graphic 211.6b Depicts an example of a 1-story, 2-story, 3-story, and 4-story commercial/mixed use cross-section. [image omitted; see the official code] KEY (SH-CG and SH-CI): Table 211.6b See also Sec. 27-43 Definitions | GF: Ground Floor UF: Upper Floor PBH: Principal building height ABH: Accessory building height | SF: Square feet PW: Parapet wall UFA: Usable floor area min: minimum Use Placement GF | Commercial, office/private institutional, governmental/public institutional, recreation/assembly, residential (as permitted in Table SH-25.1) UF | Office/private institutional, governmental/public institutional, recreation/assembly, residential (as permitted in Table SH-25.1) Maximum Height [1] PBH | SH-CG: 3-stories (45 feet); SH-CI: 4-stories (55 feet) ABH | 2-stories (25 feet) [2] PW | 7′ above PBH and ABH [4] Elevator/mechanical housing, steeples, widow's walk, cupolas, other architecturally integrated design features. | Exempt, except shall occupy no more than 20 percent of roof area. Miscellaneous Standards Minimum transparency, such as architectural features or elements as defined in Sec. 27-43, window boxes, doors and windows, for nonresidential façades along FB and SSB, measured within first 15 feet (from grade) of the façade. | 40 percent for all non-residential uses Maximum allowable aluminum, other metal siding, or plastic/PVC that can be used on any Front or Side Street façade [3] | 25 percent Notes: [1] Height is measured from finished grade to highest point of structure (see Sec. 27-43 Definitions). [2] ABH shall be reduced to 2-story (22.5 feet) when located within 20 feet of a 1-story residential principal building (not located on subject parcel). [3] Aluminum, other metal siding, or plastic/PVC materials shall only be used as accent or ancillary materials. [4] PW maximum of 7′ above maximum height for PBH and ABH for decorative and screening purposes. (c) Parking placement, layout, and general ratio standards: all development shall comply with development standards set forth below: Graphic 211.6c [image omitted; see the official code] KEY (SH-CG and SH-CI): Table 211.5c See also Sec. 27-43 Definitions | F: Front SS: Side (street) SI: Side (Interior) R: Rear | SF: Square Feet UFA: Usable Floor Area | <: Less than >: Greater than =: Equal to Parking Placement (location of parking space(s)) [2, 3] Setback F | 15' SS | 15' SI | 3' [1] R - Adjacent to/separated by alley from detached or attached residential use - Adjacent to any other use (no alley) - Adjacent to any other use (separated by alley) | 8' 3' [1] 5' Required Spaces (see Table SH-25.1 for other permitted uses) | Minimum Ratio (spaces per unit) (see Table 211.12 for other ratios by use) General Retail | 4 / 1000 SF (UFA) Restaurant <100 occupants | 6 / 1000 SF (UFA) Restaurant >=100 occupants | 0.25 per person Office, business-professional | 3 / 1000 SF (UFA) Office, medical | 5 / 1000 SF (UFA) Notes: [1] Parking pad (pavement) set back may be reduced to 0' for shared access and parking areas. [2] 80% of onsite parking shall be located to the side or rear of the principal building. [3] Structured parking (when applicable): Façades of garages must be architecturally embellished and integrated with the overall design of the development on all sides visible to right-of-way.
(Ord. No. 2023-128, § 4, 9-21-2023; Ord. No. 2025-141, § 9, 12-4-2025)
Ask a question about Tampa law
Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.