§ 10-50903.3.1 — INSTALLATION REQUIREMENTS

Fresno Municipal Code (Supp. No. 55, Update 1 (online June 23, 2026): codified through Ordinance No. 2026-019) · Fresno Municipal Code § 10-50903.3.1

Corpus is an independent public-information project, not the official City of Fresno website. Stable reference: corpuslaw.us/code/a5fe3dd8-cb73-4543-a2b2-b2f6ceb67149

SEC. 10-50903.3.1. - INSTALLATION REQUIREMENTS.

903.3.1. Standards. Automatic sprinkler systems shall be designed and installed in accordance with Sections 903.3.1.1, unless otherwise permitted by Sections 903.3.1.2, 903.3.1.3, other chapters of this code, and the requirements of the Fresno Municipal Code, as applicable. Automatic fire sprinklers or fire sprinkler systems not required by the California Building Standards Code may be of any type approved by the fire code official. 903.3.1.1. NFPA 13 sprinkler systems. Where the provisions of this code require that a building or portion thereof be equipped throughout with an automatic sprinkler system in accordance with this section, sprinklers shall be installed throughout in accordance with NFPA 13 as amended in Chapter 80 and the Fresno Municipal Code, except as provided for in sections 903.3.1.1.1 through 903.3.1.1.3. 903.3.1.1.1: Exempt locations. Automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprinklers shall not be omitted from a room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment. 1. A room or space where sprinklers constitute a serious life or fire hazard because of the nature of the contents, as determined by the authority having jurisdiction. 2. Machine rooms, machinery spaces, control rooms, control spaces and hoistways associated with fire service access elevators in accordance with Section 3007. 3. Machine rooms, machinery spaces, control rooms and control spaces and hoistways associated with occupant evacuation elevators designed in accordance with Section 3008 of the California Building Code. 4. Spaces or areas in telecommunications buildings used exclusively for telecommunications equipment, and associated electrical power distribution equipment, provided those spaces or areas are equipped throughout with an automatic smoke detection system in accordance with Section 907.2 and are separated from the remainder of the building by not less than 1-hour fire barriers constructed in accordance with Section 707 of the California Building Code or not less than 2-hour horizontal assemblies constructed in accordance with Section 712 of the California Building Code, or both. 903.3.1.1.2. Bathrooms. In Group R occupancies, sprinklers installed per NFPA 13, shall not be required in bathrooms that do not exceed 55 square feet (5 m2) in area and are located within individual dwelling units or sleeping units, provided that walls and ceilings, including the walls and ceilings behind a shower enclosure or tub, are of noncombustible or limited-combustible materials with a 15-minute thermal barrier rating. Exception: 1. Group R occupancies where automatic fire sprinklers are, or were, used as a substitution for any other California Building Code requirements. 903.3.1.1.2.1. Closets. In Group R occupancies, sprinklers installed per NFPA 13, shall not be required in closets that do not exceed 12 square feet (5 m2) in area and are located within individual dwelling units or sleeping units, provided that walls and ceilings are of noncombustible or limited-combustible materials with a 15-minute thermal barrier rating. Exception: 1. Group R occupancies where fire sprinklers are, or were, used as a substitution for any other California Building Code requirements. 903.3.1.1.5. Group R Mixed Occupancy Buildings. Mixed occupancy buildings containing Group R occupancies shall be provided with automatic sprinkler systems in accordance with Section 903.3.1.1 (NFPA 13) including the sprinkler requirements for bathrooms and closets. The Group R residential portion of a mixed occupancy building shall be provided with fire sprinkler piping and control valves arranged so that the automatic sprinkler system will remain in service independent of any non-residential occupancies. Exceptions: 1. Mixed occupancy buildings where a vertical fire barrier with no openings is provided in accordance with California Building Code, Section 707 separating the R occupancy from other uses may have automatic sprinkler systems installed in the residential portion in accordance with Sections 903.3.1.2 or 903.3.1.3 as applicable. Separate control valves shall be installed as indicated above unless otherwise approved by the fire code official. 2. Group R-1 or R-2 occupancies with accessory occupancy groups that do not require installation of fire sprinklers by Section 903.2. 903.3.1.1.6. Joint Live Work Units Quarters. Where joint live/work residential dwelling units are constructed in accordance with Fresno Municipal Code, Chapter 11, Article 7, automatic fire sprinkler systems shall be designed in accordance with Section 903.3.1.1 (NFPA 13) including the requirements for bathrooms and closets. 903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinkler systems in Group R occupancies shall be permitted to be installed throughout in accordance with NFPA 13R as amended in Chapter 80 and by the Fresno Municipal Code, except where prohibited in Sections 903.3.1.1.5 and 903.3.1.1.6, and as noted below: 1. Three stories or less above grade plane. 2. The floor level of the highest story is 30 feet (9144 mm) or less above the lowest level of fire department vehicle access. 3. The floor level of the lowest story is 30 feet (9144 mm) or less below the lowest level of fire department vehicle access. The number of stories of Group R occupancies constructed in accordance with Sections 510.2 and 510.4 of the California Building Code shall be measured from grade plane. 903.3.1.2.1. Balconies, Decks, Entryways, and Patios. Sprinkler protection shall be provided for exterior balconies, decks, ground floor patios, and entryways (enclosed on two or more sides) of dwellings, dwelling units, and sleeping units where either of the following conditions exists: 1. The building is of Type V construction, provided that there is a roof or deck above. 2. Exterior balconies, decks and ground floor patios of dwellings, dwelling units, and sleeping units are constructed in accordance with Section 705.2.3.1, Exception 3 of the California Building Code. Sidewall sprinklers that are used to protect such areas shall be permitted to be located such that their deflectors are within 1 inch (25 mm) to 6 inches (152 mm) below the structural members and a maximum distance of 14 inches (356 mm) below the deck of the exterior balconies, decks, and entryways that are constructed of open wood joist construction. 903.3.1.2.3. Attics. Attic protection shall be provided as follows: 1. Attics that are used or intended for living purposes or storage shall be protected by an automatic sprinkler system. 2. Where fuel-fired equipment is installed in an unsprinklered attic, not fewer than one quick-response intermediate temperature sprinkler shall be installed above the equipment. 3. Where located in a building of Type III, Type IV, or Type V construction designed in accordance with Section 510.2 or 510.4 of the California Building Code, attics not required by Item 1 to have sprinklers shall comply with one of the following if the roof assembly is located more than 30 feet above the lowest level of required fire department vehicle access: 3.1. Provide automatic sprinkler system protection. 3.2. Construct the attic using entirely noncombustible materials. 3.3. Construct the attic using fire retardant-treated wood complying with Section 2303.2 of the California Building Code. 3.4. Fill the entire attic with noncombustible insulation. The height of the roof assembly shall be determined by measuring the distance from the lowest required fire vehicle access road surface adjacent to the building to the eave of the highest pitched roof, the intersection of the highest roof to the exterior wall, or the top of the highest parapet, whichever yields the greatest distance. For the purpose of this measurement, required fire vehicle access roads shall include only those roads that are necessary for compliance with Section 503. 4. Group R-4, Condition 2 occupancy attics not required by Item 1 to have sprinklers shall comply with one of the following: 4.1. Provide automatic sprinkler system protection. 4.2. Provide a heat detection system throughout the attic that is arranged to activate the building fire alarm system. 4.3. Construct the attic using noncombustible materials. 4.4. Construct the attic using fire-retardant-treated wood complying with Section 2303.2 of the California Building Code. 4.5. Fill the attic with noncombustible insulation. 903.3.1.2.3.1 Bathrooms. In Group R occupancies, sprinklers installed per NFPA 13R, shall not be required in bathrooms that do not exceed 55 square feet (5 m2) in area and are located within individual dwelling units or sleeping units, provided that walls and ceilings, including the walls and ceilings behind a shower enclosure or tub, are of noncombustible or limited-combustible materials with a 15-minute thermal barrier rating. Exception: Group R occupancies where automatic fire sprinklers are, or were, used as a substitution for any other California Building Code requirements. 903.3.1.2.3.1.2 Closets. In Group R occupancies, other than Group R-4 occupancies, sprinklers installed per NFPA 13R, shall not be required in closets that do not exceed 12 square feet (5 m2) in area and are located within individual dwelling units or sleeping units, provided that walls and ceilings are of noncombustible or limited-combustible materials with a 15-minute thermal barrier rating. Exception: Group R occupancies where fire sprinklers are, or were, used as a substitution for any other California Building Code requirements.

(Added Ord. 2025-039, § 3, eff. 10-31-25).

Ask a question about Fresno law

Corpus searches the Fresno sections it holds and shows the ones that match, with their citations. Free, no sign-in.