For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 49-1435 — Two-way cleanout

Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1435

Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/a6676dba-e356-4057-8dd0-8912b257155f

Sec. 49-1435. - Two-way cleanout.

A two-way cleanout shall comply with the following provisions: (a) Shall be installed at the lower end of all building drains and storm drain eight inches and smaller. (b) Shall be extended to grade in a serviceable location. (c) The minimum opening shall be four inches in diameter. (d) A manhole shall be installed on all building sanitary and storm drains ten inches and larger within 15 feet of the building. Exception: An area inlet may be used on storm drains only. Exceptions are the following: (a) Dwellings and townhouses, if the developed length from the first three-inch or larger cleanout inside the building to the wye connection at the city main is 120 feet or less. (b) Building drains extending beyond the building to a manhole that is 50 feet or less from the building. (c) Building storm drains that daylight 100 feet or less from the building shall not require a two-way cleanout, manhole or area inlet.

(Ord. No. 40524, § 1, 10-20-15)

Ask a question about Omaha law

Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.