§ 22.30.070 — Ground Floor Urban Design Standards for Retail, Activating, and Pedestrian-Oriented Uses
Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 22.30.070
Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/a66a89d9-8432-4558-a185-a06688790f4b
22.30.070 - Ground Floor Urban Design Standards for Retail, Activating, and Pedestrian-Oriented Uses.
The following standards shall apply to the design of retail, activating, and pedestrian-oriented uses: A. Plate Height. Ground-floor height (floor-to-ceiling) for commercial uses (in a commercial or mixed use zoning district) shall be a minimum of twelve (12) feet, however fifteen (15) feet is encouraged. Ground-floor residential uses are not subject to this standard. B. Ground Floor Entrances. The primary entrance for all uses shall be located on the primary street-facing frontage of each building, and shall open onto a sidewalk, public open space, or pedestrian pathway that is a minimum of four (4) feet in width and leads directly to the sidewalk. All entrances shall be set back at least thirty inches (30") from the public right-of-way. 1. A primary entrance shall be distinguishable by at least one of the following design features: a. An awning or canopy, b. A recessed entry, or c. Another architectural element or feature that creates a well-defined entrance. 2. Façade architectural and building elements (not including any building area or habitable space) may project over the public right-of-way if approved by the Director of Public Works. C. Pedestrian Paseos. A retail building in which the rear of the development abuts a public street, and with a building street frontage of greater than two hundred (200) feet, shall provide a pedestrian path from the rear to primary frontage to allow direct pedestrian access to store entrances. D. Orientation (all uses). Where courtyards, paseos, or greenways are proposed, restaurant, retail, or other uses shall face these spaces with at least one element of windows, front doors, or outdoor patios, which shall be designed to conform to standards of this Section. This requirement shall apply in addition to the standards for primary and secondary street frontage requirements. E. Transparency (residential units). A residential building façade on a primary frontage shall be provided with windows for at least fifteen percent (15%) of the building façade on the ground floor. Windows shall have a transmittance factor of at least sixty percent (60%), and a reflectance factor of not greater than twenty-five percent (25%). F. Transparency (commercial space and residential common/amenity space). A street-facing façade for commercial building area or residential common or amenity area shall be provided with windows for at least thirty percent (30%) of the building façade on the ground floor. Windows should provide views into work, display, and sales areas or a lobby, fitness center, community room, or similar space. Windows shall have a transmittance factor of at least sixty percent (60%), and a reflectance factor of not greater than twenty-five percent (25%). 1. Window area shall be measured as the percentage of the building elevation consisting of window openings between a height of two (2) and ten (10) feet above curb grade. Storefront window systems and glass doors may be included in this calculation. 2. The use of tinted, mirrored, or highly reflective coatings, films, or applications on window glass shall be prohibited. 3. Blinds, drapes, and other window treatments, signs and posters, shelving, boxes, and products, and other visual obstructions shall not obscure more than thirty percent (30%) of the total window area on each building elevation. This requirement shall not apply to treatment or exam areas or corridors of medical offices and other medical uses. G. Pedestrian-Oriented Features. Awnings, signs, and other projecting building features shall be located at least 8 feet above the adjacent sidewalk or walkway, or higher as required by the Director of Public Works or Building Official. These features may project over the public right-of-way if approved by the Director of Public Works but shall not conflict with any adjacent street trees. H. Awning Separation. Awnings shall be limited to individual awnings per each building storefront or tenant space, unless a larger awning is approved through the Site Plan Review procedure. I. Outdoor dining. See Section 22.20.070 for additional standards applicable to outdoor dining. Table 30-1 Development Standards: Intensity Table 30-1 Development Standards: Intensity Zones | Notes and Exceptions Code section numbers reference the Long Beach Municipal Code RMU3/RMU3-A | RMU4/RMU4-A | MU-1/MU-1-A | MU-2/MU-2-A | MU-M | MU-3/MU-3-A | C3/C3-A | C-M Minimum Lot Size | 3,000 sq. ft. | 10,000 sq. ft. | 3,000 sq. ft | Minimum only applies to new subdivision of existing lots Maximum Building Height | Consistent with the General Plan; see City-wide District Height Map | Height limits will be designated by zoning district suffix as reflected in the General Plan Height Limit map Commercial Floor Area Ratio (FAR) Requirements Minimum Required | 0.0 | 0.0 | 0.25 | 0.5 | 0.5 | 0.5 | 0.25 | 0.25 | FAR requirements apply to non-residential component only Maximum Permitted | 1.0 | 1.5 | 1.0 | 1.5 | 1.5 | 1.5 | 2.75 | 2.75 Table 30-2 Development Standards: Building Placement and Activation Table 30-2 Development Standards: Building Placement & Activation Zones | Notes and Exceptions Code section numbers reference the Long Beach Municipal Code RMU3/RMU3-A | RMU4/RMU4-A | MU-1/MU-1-A | MU-2/MU-2-A | MU-M | MU-3/MU-3-A | C3/C3-A | C-M Minimum Required Setback Building Setback - Measured from minimum property line to Building Face (Feet)1 Primary Frontage See 22.30.140 for Primary and Secondary Frontage definitions A | Residential stories | 5 ft. | 3 ft. | 3 ft. | 5 ft. | 5 ft. | 3 ft. | Not Permitted | Not Permitted B | Non-residential Stories | 5ft. | 3 ft. | 3 ft. | 3 ft. | 0 ft. | 3 ft. | 3 ft. | 0 ft. C | Secondary/All Other Street Frontages | 5 ft. | 3 ft. | 3 ft. | 3 ft. | 3 ft. | 2 ft. | 2 ft. | 3 ft. D | Balconies | 10 ft. | From face of curb, from any street. Balconies cannot encroach into public right-of-way Interior Building Setbacks (Feet) E | Alley | 12 ft. from centerline of the alley Adjacent to existing single-family homes within R1 zones, where not separated by an alley F | Stories 1—2 | 4 ft. | Balconies and other open space projection cannot exceed 3 feet into required setback area on upper stories. No projection permitted at stories 1, 2. Stories 3 and above | 9 ft. | 20 ft. G | All Other Circumstances | 0 ft. Active Ground Floor Condition, Minimum Required Per Lot/Development Primary Frontage | 25% | 25% | 25% | 25% | 50% | 50% | 25% | 50% | See Map Atlas, and Section 8 of this Chapter for standards Secondary Frontage | - | - | - | 25% | 25% | 50% | - | - Notes: 1. Projections are permitted in the required setbacks in accordance with Section 21.32.220(C).
(ORD-26-0018 §§ 9—11, 2026; ORD-24-0015 § 1(Exh. A), 2024)
Ask a question about Long Beach law
Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.