Duty cycle.
46 C.F.R. § 111.25-15
in effectEach motor must be rated for continuous duty, except a motor for an application listed in Table 111.25-15 or a similar duty must meet the minimum short-time rating stated in the table.
Table 111.25-15
Application of motor
Minimum short-time rating of motor, in hours
Deck winch and direct acting capstanHalf.
Deck winch with hydraulic transmissionContinuous at no load followed by
1/2 hr. at full load.
Direct acting windlassOne fourth.
Windlass with hydraulic transmissionHalf hour idle pump operation, followed by
1/4 hr. full load operation.
Steering gear, direct actingOne.
Steering gear, indirect driveContinuous operation at 15 pct. load followed by 1 hr. at full load.
Watertight door operators
1/12.
Boat winches
1/12.