Sec. 7-194.5. - GCE sizing.

(a) Minimum acceptable size of GCE for each FSE classification will be as follows: (1) Class 1: Delicatessen, ice cream shops, beverage bars, mobil food vendors, meat markets, retail bakeries - 20 gpm/40 pound grease trap (NAICS 445110, 722515, 445210, 311811, 722330) (2) Class 2: Limited-service restaurants, day care centers, religious organizations, snack and non-alcoholic bars with on premise cooking, convenience stores, caterers, banquet halls (i.e. event centers) - 1,000 gallon grease interceptor (NAICS 722513, 624410, 813110, 722515, 447110, 722320) (3) Class 3: Full service restaurants - 1,000 gallon grease interceptor (NAICS 722310) (4) Class 4: Buffet and cafeteria facilities - 1,500 gallon grease interceptor (NAICS 722514) (5) Class 5: Institutions (schools, hospitals, prisons, etc.) - 2,000 gallon grease interceptor (NAICS 611110, 611310, 623311, 623312, 722310, 922140) (b) When calculating the appropriate size GCE, the FSE's licensed plumber or professional engineer should use a design approach that considers fixture units, storage capacity, type of facility and an adequate retention time. (c) The city will review GCE sizing information referenced on the submitted Grease Control Inquiry Form (Attachment F) or the FSE's engineer's construction plans. The city will make a decision to approve, or require additional grease interceptor volume, based on the type of FSE, the number of fixture units, and other factors. Grease interceptor capacity should not exceed three thousand (3,000) gallons for each interceptor tank. In the event that the grease interceptor calculated capacity needs to exceed three thousand (3,000) gallons, the FSE shall install an additional interceptor of the appropriate size. If additional interceptors are required, they shall be installed in series. (d) Grease interceptors that are installed in series shall be installed in such a manner as to ensure positive flow between the tanks at all times. Therefore, tanks shall be installed so that the inlet invert of each successive tank shall be a minimum of two inches (2″) below the outlet invert of the preceding tank. (e) GCE must remove FOG at or below the city oil and grease limit of 100 mg/L. Failure to comply will result in enforcement action.

(Ord. No. 18-001, § I, 1-25-18)

Ask a question about Greenville law

Corpus searches the Greenville sections it holds and shows the ones that match, with their citations. Free, no sign-in.