For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 35-1902 — General requirements

Code of the City of Chandler (Supp. No. 80: codified through Ordinance No. 5171, adopted July 13, 2026) · Chandler City Code § 35-1902

Corpus is an independent public-information project, not the official City of Chandler website. Stable reference: corpuslaw.us/code/a6bf07fe-76d1-4bab-8dd1-dc945f173f80

35-1902. - General requirements.

(1) These general requirements shall apply to all developments except for single-family dwellings, duplexes, triplexes, and fourplexes that occur on an individual isolated basis and are not part of a larger project. (2) The site development plan shall graphically and verbally indicate the following information: (a) Existing data: 1. Name, address of owner, engineer and/or architect. 2. Legal description of property. 3. Boundary of property (dimensioned). 4. Scale of drawing and north point. 5. Area of property (square feet). 6. Zoning of adjoining property. 7. Existing street(s), right-of-way, name and improvements (curb, gutter, sidewalk, paving and driveways). 8. Existing alley(s) right-of-way and type of improvement. 9. Existing buildings on property. 10. Location of existing utilities serving property. 11. Location of existing ditches, canals, fences, easements (width and use) or other physical structures on or adjacent to the property. 12. Location of fire hydrants within three hundred (300) feet of property. 13. Existing elevation of all property corners and at midpoints along all property lines. (b) Proposed improvements: 1. Location, width, and type of required improvements to all existing street(s) and/or alley(s). 2. Location, width of right-of-way, and type of improvement for proposed street(s) and/or alley(s). 3. Location, size, and type of all proposed utility lines, gas, telephone, electric, water and sewer. 4. Location and width of proposed driveways. 5. Location and extent of parking area (spaces and aisle dimensioned). 6. Location, size, finish floor elevation area, and use of proposed building(s). 7. Designation of refuse service area. 8. Location and area of all landscape and/or stormwater retention areas. 9. Proposed finished elevations for paved areas, retention areas, and landscape areas. 10. Two sets of stormwater retention calculations; arrows shall indicate direction of surface water flow. 11. Location and size of detached sign(s). 12. Location of light poles with arrows indicating direction of light rays. 13. Location, height, and type of material for fences, walls, etc. 14. Construction drawings and specifications for all off-site improvements. (3) Site organization: (a) Setbacks: 1. For parking lots: a. In proximity to street intersections. See below 2.a. b. Along arterial streets and collector streets, parking lots shall be set back at least twenty (20) feet from right-of-way lines. c. Along all other rights-of-way and property lines, unless said property lines are of a smaller parcel (pad) within a larger planned development, all parking spaces and access drives shall be set back at least ten (10) feet. 2. For structures or any physical improvement in proximity to street intersections: a. Intersections as described below are of value to the entire community. Land situated at the corner of such street intersections shall be landscaped, and remain open and free of buildings, parking areas, driveways, and walls taller than two (2) feet six (6) inches in height. Ingress and egress drives perpendicular to the street are expected. The dimensions of these open areas shall satisfy at a minimum, the following standards: Type of Intersections | Setback From Right-of-Way | Setback Shall Apply for a Distance From the Intersection for Arterial street with arterial street | 50 feet | 250 feet along both streets Arterial street with any other street | 50 feet | 100 feet along arterial street 30 feet | 100 feet along other street Collector street with collector street | 30 feet | 60 feet along both streets b. No vehicle or other obstruction exceeding two (2) feet in height shall be parked at an intersection of two (2) right-of-way lines within triangular area formed by the right-of-way lines and the line connecting them between points located thirty (30) feet from the intersection of said lines. c. In order to accommodate, encourage, or promote infill development or redevelopment on properties located within the infill incentive district, the Zoning Administrator may reduce the landscape intersection setbacks by up to twenty-five (25) feet for arterial streets and up to fifteen (15) feet for collector streets after having made a finding in writing that all of the following criteria have been met: 1) Such deviation, on balance, will result in a superior environmental and design quality through items such as but not limited to: i. Increased levels of architectural quality ii. Greater material diversity iii. Enhanced usable space and/or pedestrian connection iv. Activation of street frontage v. Higher level of landscape design vi. Creative design solutions for back-of-house functions 2) The site is designed to ensure safe and adequate onsite traffic circulation and prevent drive-through queuing from backing onto main driveways or public streets; 3) Sufficient parking is provided on-site; 4) The development will enhance the quality of a neighborhood by developing a vacant lot or redeveloping an existing dilapidated commercial building or center; and 5) The development complies with required setbacks and landscape buffers from adjacent residential properties. (b) Retention basins: 1. Retention basins may be located in the front yard of parking lots and buildings when they: a. Do not occupy more than one-half (½) of the landscaped area, when designed to maximum allowable engineering specifications. This requirement is only applicable to non- residential zoned properties that are ten (10) acres and larger. (c) Walkways: Walkways shall be provided as required by ADA regulations and objective design standards provided herein. (d) Bike storage: Bicycle storage and/or secure bicycle parking shall be provided adjacent to the primary entry of any building. A minimum of three (3) bicycle parking spaces shall be provided, or at least one (1) bicycle space per twenty-five (25) off-street parking spaces shall be provided, whichever is greater. 1. Design and location. Required bicycle parking spaces must: a. Consist of racks or lockers anchored so that they cannot be easily removed and of solid construction, resistant to rust, corrosion, hammers, and saws; b. Allow both the bicycle frame and the wheels to be locked using a standard U-lock; c. Be designed so as not to cause damage to the bicycle; d. Facilitate easy locking without interference from or to adjacent bicycles; e. Be located in convenient, highly visible, active, well-lit areas without interfering with pedestrian movements; and f. Have minimum dimensions of two (2) feet in width by six (6) feet in length, with a minimum overhead vertical clearance of seven (7) feet. (e) Screen walls: Screen walls shall be decorative and reflect color, material and/or design of the structure to which it prevails. (4) Building architecture: (a) Metal buildings: 1. Metal buildings will not be allowed on roads designated by the general plan as arterial roads except that: a. A portion of a building may be constructed using an exterior metal finish as an accent material and/or where said portion does not exceed twenty-five (25) percent of each elevation. b. Shipping containers may be used as a building material if the building is designed with additional materials and fenestration to enhance the quality of the architecture that together provide a creative and innovative architectural design. The character, scale, and massing of said design shall be compatible with the buildings of the surrounding area. (b) Parking shade canopies: 1. Canopy covers shall meet all of the following requirements: a. Painted to match existing/proposed building(s) on-site b. If additional materials are used on the canopy, they shall be materials featured on the site's primary building c. Provide a 6" minimum fascia on all sides d. Provide landscaping islands between canopies e. No wide flange beams (i.e. "I" or "H" beams) are permitted unless wide flange beams are used as a material on the existing/proposed building(s) on-site 2. Solar canopy covers shall meet the requirements in the above section, in addition to the following: a. Any equipment attached to the canopy shall be painted to match the canopy. b. Any ground-mounted equipment adjacent to the canopy shall be fully screened by solid masonry walls and gates equal to, or greater than, the highest point on the mechanical equipment. enclosure walls shall use materials and colors to match existing materials and colors on the site. (c) Roof-mounted mechanical equipment screening: All mechanical equipment and appurtenances shall be concealed and/or screened from view in their entirety as an integral part of the building while meeting the following requirements, and subject to approval by the zoning administrator: 1. New buildings: All roof mounted mechanical equipment shall be fully screened by parapet walls equal to, or greater than, the highest point on the mechanical equipment. 2. Existing buildings: Existing buildings shall use a secondary roof screening method when mechanical equipment cannot be screened by top of parapet. Secondary screening methods shall meet the following requirements: a. Buildings utilizing secondary screening shall screen all equipment within one enclosure. Meaning, there cannot be multiple, separate enclosures on one roof to screen individual pieces or groups of equipment. b. Secondary screening methods shall utilize materials and colors found elsewhere on the building or one of the following methods: i. Louver system with slats angled to ensure no equipment visibility; or, ii. Mesh screen system that meets one of the following hole size and open area (O/A) measurements: 1) Hole size: 3/32"; O/A: 23% 2) Hole size: 1/8"; O/A: 23% 3. Parapet or roof screening shall be fully enclosed with no openings. If an opening is needed for maintenance access, a door shall be included in the parapet/roof screening rather than an opening. The door shall match the material(s) and color(s) used for the parapet/roof screening in which the door is located. 4. All mechanical equipment and appurtenances shall be indicated and shown on building sections and elevations indicating dimensions of equipment and screening. The Zoning Administrator may reduce or waive screening requirements for roof-mounted equipment if: i. The building is a mid-rise development and roof-mounted equipment will not be visible from any adjacent property as seen from a point six (6) feet above ground level at the property line or sidewalk on the opposite side of the street; or ii. The building is located within an industrial center or business park and roof-mounted equipment will not be visible from any arterial street or residential property. (d) Service entrance section (SES): Screening for the service entrance section (SES) shall be architecturally integrated into the building and shall appear as an integral part of the building. This shall be accomplished using one of the following methods: a. Recess SES into building with building walls flush to edge of cabinet. A gap of no larger than three (3) inches is permitted between the sides and top of cabinet and the building wall. SES cabinet shall be painted to match the building. b. Provide a room within the building where the ses is located. External doors shall be provided. Color of external doors shall match the building. (e) All ground-mounted equipment shall be screened from public view by a concrete or masonry wall, equal to or greater in height than the height of the mechanical equipment. Screening of mechanical equipment shall be constructed of similar materials and painted colors similar to the building, and so arranged that the screening is perceived to be an integral part of the building mass. (f) All transformer boxes, meter panels, back-flow devices and any other utility equipment (excluding the SES), not able to be screened by landscaping or walls, shall be painted to match the building color. (g) Roof access ladders shall be located inside the building for new buildings. Exterior roof access ladders on existing buildings shall be painted to match the building only when changes to the existing building changes are limited to color and material changes. If more than fifty percent (50%) of the building exterior is modified, excluding color and material changes, then exterior roof ladders shall be relocated to inside the building. (h) Roof drainage shall utilize interior roof drains for new buildings. Exterior roof drainage on existing buildings shall be painted to match the building only when changes to the existing building changes are limited to color and material changes. If more than fifty percent (50%) of the building exterior is modified, excluding color and material changes, then exterior roof drainage shall be relocated to inside the building. (i) Trash collection areas: 1. All trash and/or refuse collection areas shall be enclosed by a six-foot masonry or concrete wall, excluding approved openings. The location of such area shall be approved by the department of public works. 2. Enclosures shall incorporate the same materials and colors as the primary building design. 3. Enclosures shall be located and positioned as to ensure that gate openings are not visible from any arterial road or residential property. 4. Enclosures shall be located and positioned as to ensure that no portion of the enclosure (walls, gates, curbing, etc.) overlaps with adjacent required drive aisle. this includes when the trash enclosure gates are open. 5. If the trash and/or refuse enclosure includes a trash compactor or other equipment, the trash enclosure walls and gate shall be a height equal to or greater than the maximum height of the trash compactor or equipment. (j) Electric vehicle charging stations: 1. All electric vehicle charging (EVC) spaces, charging stations, and associated transformers or other mechanical equipment, shall be provided on site, shall not displace any required parking spaces, and shall not be located within any required landscape setback or required landscape area. 2. All ground mounted equipment shall be fully screened by solid masonry walls and gates built to a height equal to, or greater than, the highest point on the mechanical equipment. Enclosure walls shall use materials and colors to match existing materials and colors on the site. 3. All transformer boxes and any other utility equipment not able to be screened by walls shall be painted to match the color of the building(s) on-site. 4. No advertising signage is permitted on the EVC spaces or associated equipment. (k) All external lighting shall be so located and designed to prevent lighting rays from being directed off of the property upon which the lighting is located. A photometric study shall be provided to show zero (0) foot candles at the subject property lines

(Ord. No. 5142, § 2(Exh. A), 11-13-25)

Ask a question about Chandler law

Corpus searches the Chandler sections it holds and shows the ones that match, with their citations. Free, no sign-in.