Sec. 66.343. - Traditional neighborhood district design standards.
(a) Applicability. This section applies to development within T1-T4 traditional neighborhood districts. In cases where more specific design standards or guidelines have been developed as part of city council-approved master plans, small area plans, or other city-approved plans for specific sites, those take precedence. Standards in Section 63.110, building design standards, also apply.
(b) Traditional neighborhood district design standards.
(1) Compatible rehabilitation and reuse. Remodeling, additions or other alterations to existing traditional buildings must be done in a manner that is compatible with the original scale, massing, detailing, glazing and materials of the original building. Original materials must be retained and preserved to the extent possible. Traditional buildings are typically sited close to the property line along the street and feature architectural and design elements that relate to the human scale.
(2) Front yard landscaping. Front yard areas located between the principal building and the street must be landscaped, except on University Avenue where the first four (4) feet may be paved similar to the public sidewalk. Other hard surfaced front yard areas should include amenities such as benches, tables, and planters. The amenities must be placed in a manner that does not create blind corners or areas of concealment.
(3) Building facade continuity. New buildings along commercial and mixed-use streets must provide a continuous facade along the street. Where breaks occur, the street edge must be continued through the use of fencing, low walls, landscaping and/or similar treatments. Civic and institutional uses are exempt.
(4) Frontage elements. The base thirty (30) feet of building sides facing abutting public streets must include elements that relate to the human scale at grade. Elements include doors, windows, projections, awnings, canopies, porches, stoops, etc.
(5) Building roofline design. One-story buildings must be designed to convey an impression of greater height in relation to the street with design elements such as pitched roofs with dormers or gables facing the street, tall parapets, and/or the use of an intermediate cornice line to separate the ground floor and the roof. Buildings of two (2) or more stories must include a cornice, parapet, or roof overhang in the area between the top floor and highest point of the building.
(6) Entrance location. There must be a primary pedestrian building entrance on all arterial or collector streets. At a corner location where both streets are arterial or collector streets, this standard may be satisfied with a single entrance at the corner. In multi-tenant buildings, any ground floor nonresidential use with street frontage must have an entrance facing the street or outdoor pedestrian-oriented courtyard on a primary street frontage.
(7) Door and window openings.
a. For new commercial and civic buildings, windows and doors or openings must comprise at least fifty (50) percent of the length and at least thirty (30) percent of the area of the ground floor along arterial and collector street facades.
b. Window shape, size and patterns must emphasize the intended organization of the facade and the definition of the building.
(8) Building materials.
Residential buildings of more than six (6) units and nonresidential or mixed-use buildings must be built with high-quality materials such as brick, stone, textured cast stone, tinted masonry units, concrete, fiber cement siding, glass or metal. The following materials are not allowed:
- Unadorned plain or painted concrete block;
- Corrugated metal, unless used as a limited architectural element rather than for entire walls;
- Reflective glass; and
- Vinyl, fiberglass, asphalt or fiberboard siding.
(9) Screening of equipment and service areas. If an outdoor storage, service or loading area is visible from adjacent residential uses or a public street or walkway, it must be screened by a decorative fence, wall or screen of plant material at least six (6) feet in height. Fences and walls must be decorative and architecturally compatible with the primary structure.
(10) Interconnected street and alley network. The existing street and alley network must be preserved and extended as part of any new development. Cul-de-sac streets are discouraged.
(11) Structured parking location and entrance design.
a. Entrance drives and garage doors for underground or structured parking may face the street, except adjacent to light rail transit platforms, and must be designed for pedestrian convenience and safety.
b. Vehicular entrances to structured parking must be from a side street, when available, to minimize vehicle-pedestrian conflicts, except where it is determined in the review of a site plan that side street access would create or aggravate an unsafe condition or is impractical, unreasonable, or harmful to public safety.
c. Vehicular entrances to structured parking must be minimized to the extent feasible so they do not dominate the street frontage. Possible design techniques include recessing the entry; extending portions of the structure over the entry; using screening and landscaping to soften the appearance of the entry; using the smallest curb cut and driveway possible; and subordinating the vehicular entrance to the pedestrian entrance in terms of size, prominence in the streetscape location, and design emphasis.
d. New above-grade parking structures fronting on arterial and collector streets must be lined with active commercial/retail uses at street level with direct access to the sidewalk.
e. Upper levels of parking structures must be designed with exterior wall treatments and screening to reduce the view of vehicles.
f. Structured parking must be designed with level parking floors and adequate floor-to-ceiling clearance height to allow the space to be converted to finished floor area if parking is no longer needed in the future and such design is determined cost-effective.
(12) One- or two-family garage location. Attached garages must be recessed at least ten (10) feet behind the front facade of the building. Detached garages must be located in the side or rear yard, recessed at least twenty-five (25) feet behind the front facade of the building. When an alley is present, garages must be located in the rear yard and accessed through the alley. Individual unit garage entrances must be off alleys or interior courtyards. On corner lots, access to parking may be from the side street.
(13) Parking lot lighting. Pedestrian-scale lighting must be provided within parking facilities. Light standards must be no more than twenty-five (25) feet in height in parking lots and sixteen (16) feet in height along interior sidewalks and walkways, and have a downcast glow.
(14) Entrance location for transit access. A primary building entrance must be located to provide direct access to transit stations, including light rail, bus, bus rapid transit, and streetcar.
(15) Street trees. Street trees and other landscape improvements must be planted in compliance with Section 69.600. Trees must be located in a planting strip at least five (5) feet wide between the curb and sidewalk, or in a planter or planting structure of a design acceptable to the city.
(16) Sidewalks. In T1-T3, sidewalk width must be at least five (5) feet; in T4, sidewalk width must be at least six (6) feet, or more in areas of high pedestrian activity. The T4 district is defined as an area of high pedestrian activity. See the Street Design Manual for additional information.
(Ord. No. 11-27, § 1, 4-20-11; Ord. No. 25-59, § 4, 11-12-25)