§ 5.6 — Building form and materials
Code of Ordinances, City of Oxford, Mississippi (Supp. No. 36: codified through Ordinance No. 2026-5, enacted March 17, 2026) · Oxford Code of Ordinances, App. A, art. 5.0, § 5.6
Corpus is an independent public-information project, not the official City of Oxford website. Stable reference: corpuslaw.us/code/a8ba3682-e52e-46e8-b7c1-16068296425d
Sec. 5.6. - Building form and materials.
5.6.1. Form. 5.6.1.1. When adjoining a residential zone, structures shall be compatible with the character of primarily residential zoning district. Compatibility shall be determined by comparing the consistency of existing and proposed design elements, colors, materials, height, bulk and landscaping. 5.6.1.2. Building facades shall be oriented parallel to the streets they face. Main entrances shall be visible as a means of creating continuous streetscapes. 5.6.1.3. A portion of the facade of any building over three stories in height shall step back or recess an additional 1.2 feet for every one foot of height above three stories. Exemption from this requirement may be requested by special exception. 5.6.1.4. Multiple buildings on a site should be clustered to create plaza or pedestrian mall areas. Where this cannot be achieved, buildings shall be connected by means of pedestrian walkways defined by separate paving textures and accented by landscape areas. 5.6.1.5. False or stage-set facades are prohibited. Materials and colors used on the street façade shall continue to the sides and rear of the building. 5.6.1.6. The maximum, unbroken façade plane along any street frontage is limited to 60 feet and must be interrupted by visually discernable projections, recesses, portals, courtyards, plazas, or other architectural design elements. Façade breaks shall have a minimum depth of six inches. 5.6.1.7. Form of multiple-family building design. Building designs that create variety and do not look monotonous if replicated throughout the development are required. Such designs must include all of the following elements: a. Building elevations, garages, carports, and all accessory structures shall have the same level of design, aesthetic quality, and architectural detailing. b. Porches, varied rooflines, and varied façade depths shall be provided to create variety and individuality of each building. c. Windows and projecting wall surfaces shall be used to break up larger wall surfaces, establish visual interest and provide visibility of the street and other public spaces encouraging social interaction. d. Protective entry courts, common vestibules, covered breezeways, or enclosed stair halls shall be used to reduce the number of visible doors unless designed in a row house or townhouse manner oriented toward the street. e. Garages, when provided, shall be designed to be integrated with the building design or sited so as to avoid long monotonous rows of garage doors and building walls. Garages shall be oriented so that they do not visually dominate the building façade or the streetscape. 5.6.1.8. Inappropriate façade/appropriate façade. a. No flat-faced cement block or metal surfaces shall be visible from the exterior of any building as a primary surface material or mansard. b. Parapet facades may be used when unified construction with a primary surface of a wall and of the same material and color. The parapet shall be designed so reverse side of its elements are not visible to public view. False mansards are prohibited. c. Parapet facades must be used on flat roof structures where roof mounted building equipment is used. Parapets shall extend above the highest level of any roof mounted building equipment on all sides. d. Excessively tall foundation or basement walls and their visual impact must be avoided by blending them into their setting through the use of appropriate colors, building materials, or vegetation. 5.6.1.9. Materials. Building materials must suit the architectural style of a building and be consistent or complementary throughout. Exterior surface materials shall be selected from among the following: Brick, tile, cementitious stucco, stone, vertical board and batten, wood or cementitious siding and approved architectural concrete masonry unit, or other materials if authorized by the planning director. A maximum of two percent of exterior surface may be clad with EFIS. 5.6.1.10. Roof design shall be appropriate to the architectural style of a building. Where exposed to public view, roof material shall be selected from enameled standing seam metal, concrete or clay tiles, copper metal, or wood textured (architectural grade) or composition asphalt shingles. The use of plastic, fiberglass, other metal, or glass visible to public view is prohibited. 5.6.1.11. Architecture of buildings in developments. Architecture for buildings in a development shall vary, and similar designs should not be adjacent to each other. 5.6.2. Design detail. 5.6.2.1. Wall surfaces shall be composed of at least 75 percent a single material and color. 5.6.2.2. Walls that can be seen from an arterial or major collector street shall be treated as a building front façade. 5.6.2.3. No less than 50 percent of the horizontal distance of any building front shall be designed with arcades, windows, entrances, awnings, or similar features. 5.6.2.4. Retail front facades (front and sides open to public view) shall be glazed with clear glass no less than 30 percent of the first story. Other uses may provide the authentic appearance of such transparency.
(Ord. No. 2018-11, 7-17-2018; Ord. No. 2025-19, § 1, 12-2-2025)
Ask a question about Oxford law
Corpus searches the Oxford sections it holds and shows the ones that match, with their citations. Free, no sign-in.