For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 295-705 — Design Standards

Milwaukee Code of Ordinances (Volumes 1-3 revised through Common Council action of Sept. 22, 2026) · Milwaukee Code of Ordinances § 295-705

Corpus is an independent public-information project, not the official City of Milwaukee website. Stable reference: corpuslaw.us/code/a9742f8e-fbf8-4c7f-ac22-ca3476bfc4ad

295-705. Design Standards.

1. TABLE OF STANDARDS. The design standards for buildings in downtown districts are set forth in table 295-705-1. 1.5. PURPOSES. The purposes of the design standards of this section are to: a. Maintain Compatibility with Neighborhood Context. An objective of these design standards is to ensure that buildings in downtown districts fit within the context in which they are built. Building setback, floor area, height and other design parameters vary by district to ensure that the requirements of this section closely match the existing built environment. b. Allow Flexibility in Development. Flexibility in meeting design standards is achieved by providing ranges, exceptions and alternatives which are consistent with the spirit and intent of this chapter. These ranges, exceptions and alternatives allow various site-specific and project-specific issues to be addressed while still taking into account the intention of the zoning district. c. Consistency with the Principles of Urban Design. These design standards strive to promote development that is consistent with the “Principles of Urban Design” adopted by the city plan commission as part of the city’s comprehensive plan and on file in the office of the commission and in the legislative reference bureau. Downtown development and alterations should not only be compatible with the character of the neighborhood, but also create pedestrian-friendly environments, allow varying degrees of land use diversity within each zoning district, and promote environments which support transportation diversity consistent with neighborhood context. d. Promote Usage of Sustainable Building Materials that Add Long-Term Value to Neighborhoods. Façades should be constructed of durable materials that resist denting, splitting, cracking, fading, peeling and other damage. Façade components should be finished-quality materials appropriate for street-facing character, with finished and refined edges, rather than utility-grade materials that are rough and disorderly. Façades should consist of context-appropriate materials that fit the character of urban locations throughout the city. 2. SETBACK REQUIREMENTS. a. Setback Average and Range. Whenever table 295-705-1 specifies that a setback shall be determined by averaging, the average setback shall be determined using the formula described in s. 295-505-2-b-4. When this formula is used to determine an average side street or rear street setback, the term “front setback” in s. 295-505-2-b-4 shall be interpreted as the side street setback or rear street setback, respectively. b. Building Placement. b-1. New Buildings. At least 70% of the front, side street or rear street façade of any newly constructed principal building shall meet the setback requirements of table 295-705-1. The remaining 30% or less of each façade may be placed anywhere between the property line and the specified maximum setback of 10 feet. b-2. Additions and Alterations. Where portions of an existing building are closer to the front, side street or rear street lot line than are the corresponding facades of the nearest adjacent buildings, a new addition or alteration may be placed as close to the lot line as the portion of the building closest to the lot line. Where an existing building is set back farther from the lot line than are the nearest adjacent buildings, an addition or alteration may extend as close to the lot line as the required setback specified in table 295-705-1. b-3. Removal of Portion of Building. No building may be altered by removing a portion of the building such that the front, side street or rear street façade of the building will no longer meet the setback requirements of table 295-705-1, or will be even less in conformance with those requirements than it already is. c. Solar Arrays. A ground-mounted solar array that is more than 20 feet in height shall comply with the setback regulations for a principal building. A ground-mounted solar array that is 20 feet or less in height shall comply with the front setback requirement and be set back a minimum of 1.5 feet from all side, side street and rear lot lines. 3. INTRUSIONS INTO PUBLIC RIGHT-OF-WAY. See ch. 245 for regulations pertaining to intrusions of structures into the public right-of-way. 4. CALCULATION OF PERMITTED FLOOR AREA. a. Variables. As indicated in the permitted floor area standards in table 295-705-1, one or more of the following 4 variables may be used to determine how much building floor area will be allowed for any development project: a-1. The size of the development site (W). a-2. The amount of surface open space (X). a-3. The amount of qualifying roof top open space (Y). a-4. The size of an interior atrium or mall (Z). b. Formulas. Exact formulas vary from district to district. In general, the larger the development site and the more surface open space, roof top open space or atrium space provided, the more floor area permitted. Paragraphs c to f describe how to calculate each of the 4 variables. c. Size of the Development Site (W). c-1. In most cases, the size of the development site equals the gross area of the primary building site. However, when a lot separated from the primary building site will be developed or utilized in conjunction with development of the primary building site, the gross area of such lot may be counted as part of the development site if: c-1-a. The separate lot is under the same ownership as the primary building site. c-1-b. The separate lot is or will be physically connected to the primary building site in a manner allowing human passage. c-1-c. The property owner files an overall development plan with the commissioner of neighborhood services indicating the total floor area to be constructed on the development site; and c-1-d. The property owner files a deed restriction indicating that the total floor area shown on the development plan will not be increased without the express approval of the common council. c-2. Any portion of the primary building site and any portion of a qualifying separate lot which is dedicated to the public for open space use may be counted as part of the development site. d. Amount of Surface Open Space (X). The city encourages the creation of surface open space and permits construction of additional building floor area when it is provided. The amount of surface open space equals the size of the development site (W) less: d-1. The area of the development site covered by structures at grade. d-2. The area underneath cantilevered portions of such structures where the cantilevered portions are less than 24 feet above grade; and d-3. The area of the development site designed for surface vehicular use. e. Amount of Qualifying Roof Top Open Space (Y). Sometimes plazas or other open space amenities can be created on the roof of structures. The city encourages development of roof top open space and permits construction of additional building floor area when roof top open space meets the following criteria: e-1. It will be improved in such a way that it can be classified as a walkway, plaza, courtyard or other open space amenity. e-2. Its average length and width will each exceed 10 feet. e-3. It will be open to the sky. e-4. It will be designed and intended primarily for use by the public or by the employees, residents or patrons of the development site's principal building. Improved roof top areas designed primarily for maintenance activities do not qualify. f. Size of an Interior Atrium or Mall (Z). f-1. The city encourages the creation of qualifying interior atrium or mall space which is designed in such a way that it either will or eventually could be connected to the downtown skywalk system. In certain zoning districts development of additional building floor area is permitted when such space is provided. Qualifying atrium or mall space shall: f-1-a. Be 2 or more stories in height. f-1-b. Have a volume of at least 10,000 cubic feet. f-2. The size of qualifying interior atrium or mall space shall be the volume of said space measured in cubic feet. 5. BUILDING HEIGHT. a. Exceptions to Height Limitations. All structures shall comply with the height limitations established in each zoning district, if any, except the following: a-1. Chimneys and flues. a-2. Water towers or tanks other than those located on the roof of a building. a-3. Bulkheads, elevator enclosures, penthouses, skylights or water tanks occupying in the aggregate less than 25% of the area of the roof on which they are located. a-4. Parapet walls or cornices extending above the height limit not more than 5 feet. a-5. Monuments, television reception antennae, radio reception antennae, flag poles, spires, church roofs, domes, cupolas or belfries for ornamental purposes and not used for human occupancy. a-6. Religious assemblies, convents, schools, dormitories, colleges, libraries and museums. Such a building or portion thereof may exceed the height limit of the district if the building, or portion of the building in excess of the limit, is setback from side lot lines a distance equal to one-half the height of the building or portion thereof. a-7. Transmission towers which are in compliance with the height-related standards of s. 295-703-2-u. a-8. Solar farms and solar arrays. b. Exception to Minimum Height Requirement. Motor vehicle-related uses shall not be subject to a minimum building height requirement. 5.5. GLAZING. The glazing requirements applicable to the LB3 district, as specified in s. 295-605-2-i-3, shall apply to all properties in downtown zoning districts, except properties in the C9A and C9H districts and ground floor residential uses permitted on collector and local streets, which shall meet the glazing requirements of the LB2 district. 6. FENCES. a. General. Fences shall be permitted anywhere on a lot in a downtown zoning district, including placement along property lines. For the purposes of this subsection, the term "fence" shall include a wall or other similar structure. b. Fences along Streets. Fences along streets shall not exceed a height of 4 feet, with the following exceptions: b-1. A fence may be erected to a height of 6 feet if it is set back at least 5 feet from the sidewalk, or 5 feet from the property line if there is no sidewalk. In no case does this provision allow a fence to be erected in the public right-of-way, unless a special privilege allowing such fence has been granted by the common council pursuant to ch. 245. b-2. An ornamental metal fence may be erected to a height of 8 feet. Such fence may include masonry piers, provided the fence is at least 50% open overall. An ornamental metal fence may also be constructed atop a masonry wall, provided the combined height of the wall and fence does not exceed 8 feet and the portion of the wall/fence structure above 6 feet high is at least 50% open. c. Fences along Side and Rear Lot Lines. A fence located along a side lot line or a rear lot line shall not exceed a height of 8 feet in the C9A district. No limit applies in other subdistricts. d. Barbed Wire. Barbed wire shall not be permitted except in the C9H district, where it may be used for fence purposes provided that it is located not less than 6 feet above the grade directly below the wire. Razor wire and concertina wire are prohibited in all circumstances. e. Orientation of Supporting Members. The vertical and horizontal supporting members of a fence shall face the interior of the lot on which the fence is located. f. Fence Gates and Trellises. At a gate, walkway or other entrance area, a decorative gate or trellis may extend above the permitted fence height to a maximum of 10 feet in height. A decorative gate or trellis shall not exceed 6 feet in width. g. Public-Right-of-Way. A fence or retaining wall may extend into the public right-of-way to the extent allowed by, and only in accordance with, the provisions of ss. 245-4.5 and 245-4.6 or a special privilege granted by the common council pursuant to s. 245-12. h. Fences at Construction Sites. Notwithstanding any other provisions of this paragraph, fences not exceeding 9 feet in height may be erected around construction sites and shall be removed immediately upon completion of the project. i. Fences at Sports Facilities. Notwithstanding any other provision of this paragraph, the commissioner of neighborhood services may permit a fence in excess of 6 feet in height in specific locations on a premises to prevent balls and other objects from damaging adjoining buildings or premises. j. Fences as Part of Required Screening. Notwithstanding any other provisions of this paragraph, a fence may be erected to the height necessary to comply with the screening requirement of s. 295-405-3. 6.5. CONTAINERS USED FOR SOLID WASTE DISPOSAL. Every use, except a residential building containing 4 or fewer dwelling units, shall provide an area for all dumpsters or other containers used for solid waste disposal, including containers for recycled materials. Containers used for solid waste disposal shall meet the following location and screening requirements: a. On-site Location. All containers, including dumpsters, shall be provided on-site for all uses contained within a building. This location may be in an indoor location on the premises or in an outdoor location that complies with the screening requirements of s. 295-405-6. b. Alternatives to On-Site Location. An off-site container or dumpster area location may be provided if the applicant submits documents acceptable to the department of neighborhood services showing that the applicant has entered into an agreement with an adjacent property owner for access to containers or dumpster areas that meet the screening requirements of s. 295-405-6. Alternatively, an off-site container or dumpster area location may be provided if the applicant has applied for a special privilege to place solid waste and recycled material storage containers in the public right-of-way pursuant to s. 245-12 and the commissioner of public works has found that the criteria for recommending approval of a special privilege have been met. c. Plan Submittal. Prior to the issuance of construction or alteration permits for a new use or a substantial improvement of an existing building, dumpsters or other containers used for solid waste disposal, including containers for recycled materials, and the screening for these containers, if required, shall be shown on submitted plans. 7. SIGNS. a. Sign Classification Table. Table 295-705-7 specifies the classification of various types of signs when located in the downtown districts. The sign types in this table are defined in s. 295-201. The following are the classifications indicated in table 295-705-7: a-1. "L" indicates a limited-permission sign. This sign shall be permitted only when the commissioner of neighborhood services finds that the sign will meet the standards of par. b. If the sign cannot meet these standards, it shall be permitted only upon board approval of a special use permit pursuant to s. 295-311-2, unless otherwise prohibited by par. b. a-2. "N" indicates that a sign of this type is prohibited. Table 295-705-7 DOWNTOWN DISTRICT SIGN CLASSIFICATIONS C9A | C9B | C9C | C9D | C9E | C9F | C9G | C9H On -premise Awning | L | L | L | L | L | L | L | L Canopy | L | L | L | L | L | L | L | L Hood | L | L | L | L | L | L | L | L Wall | L | L | L | L | L | L | L | L Freestanding | L | L | L | L | L | L | L | L Roof | L | L | L | L | L | L | L | L Projecting | N | L | L | L | L | L | L | L Marquee | N | L | L | L | L | L | L | L Off-premise All | N | L | N | N | N | L | N | N b. Limited-Permission Sign Standards. b-1. Awning Signs. b-1-a. The sign shall be not more than 12 inches in height. b-1-b. If the awning to which such sign is attached is made of translucent material, the awning shall not be internally illuminated. b-2. Canopy and Hood Signs. If the sign has a display area larger than 25 square feet, the sign shall be a type A sign. b-3. Wall Signs. b-3-a. If the sign has a display area larger than 50 square feet, the sign shall be a type A sign. b-3-b. The sign shall be attached only to a flat, opaque wall surface. b-4. Freestanding Signs. b-4-a. The sign’s display area shall not be larger than 35 square feet. b-4-b. The sign shall be a type A sign. b-5. Roof Signs. If the sign has a display area larger than 50 square feet, the sign shall be a type A sign. b-6. Projecting Signs. If the sign has a display area larger than 25 square feet, the sign shall be a type A sign. b-7. Marquee Signs. If the sign has a display area larger than 50 square feet, the sign may be illuminated only by internal lights. b-8. Off-Premise Signs. b-8-a. The sign shall not be located within 300 feet of a residential district or 100 feet of a residential use. b-8-b. The sign’s display area shall not be larger than 300 square feet. If this condition is not met, the sign is prohibited. b-8-c. No off-premise sign shall be placed upon any premises used as a parking lot. b-8-d. Off-premise automatic changeable message signs shall be subject to the special use permit requirement set forth in 295-407-7-d. c. Temporary Signs. The following temporary signs shall be permitted in all downtown zoning districts: c-1. A sign pertaining to the construction of a building or the sale or lease of vacant land not exceeding 72 square feet. c-2. A sign not exceeding 36 square feet erected and maintained on a lot to advertise the leasing, rental or sale of a building or other improved real estate. d. Additional Regulations. See s. 295-407 for additional regulations for on-premise and off-premise signs. 8. LANDSCAPING REQUIREMENTS. a. Following Demolition of a Structure. In addition to requirements set forth in s. 218-6-8, whenever a structure in any downtown zoning district is demolished, the site shall be covered with sodded grass and shall have at least one tree planted for every 25 lineal feet of street frontage. A continuous landscaped area at least 5 feet wide with 2 staggered rows of shrubs spaced 4 feet on center in each row and an ornamental metal fence shall be provided along all street frontages. If plans for new development on the site are submitted to the department, these landscaping requirements shall not apply. b. Uses for Which Landscaping is Required. All land uses in downtown zoning districts shall be in compliance with all applicable landscaping requirements of s. 295-405. 9. RESTRICTED BUILDING WALL MATERIALS. The following regulations apply to any non-industrial principal building or addition, as well as any accessory structure wall that is parallel to and within 10 feet of a street frontage, or a wall used for screening of mechanical equipment, trash and recycling equipment, containers used for solid waste disposal or dumpster storage area that is parallel to and within 10 feet of a street frontage: a. Metal Building Walls. The use of structural corrugated metal wall, or a metal panel-and-batten wall system such as a metal-sided, prefabricated building or a pre-engineered metal building, shall be prohibited when located on any front façade or street façade located within 100 feet of a street lot line. An architectural metal panel façade system with integral trim and integral trim connections to adjacent materials is permitted provided that the architectural metal panel system is not used closer than 1.5 feet from the ground. b. Concrete Masonry Units. Utility-grade concrete masonry units, such as standard concrete block and split-face block, are permitted along a building’s street-facing frontage provided that their use is limited to the base of the façade to a height not exceeding 2 feet 8 inches. These materials are permitted on a building’s rear, alley and interior lot line facades. c. Simulated Stucco Products. Simulated stucco products are prohibited on the ground-level area of a building, and may only be used on the upper one-third of a street façade. These materials are permitted on floors above the ground level on a building’s rear, alley and interior lot line facades. For purposes of this paragraph, the ground-level area of a one-story building is the lowest 12 feet of the building. d. Prohibited Stone Cladding. Masonry stone cladding using irregularly-shaped stones, often known as rubble masonry and which is typically laid in an un-coursed manner, is prohibited. This prohibited stone cladding may be composed of river rock of smooth oval-shaped stones or of rough, thinly-layered courses commonly known as ledgestone. Prohibited materials may be natural stone, manufactured or cultured stone, or veneer siding material. e. Fiber-Cement Siding. Fiber-cement siding, including composite material made of cement reinforced with cellulose fibers, or any material that is the equivalent of fiber-cement siding, is prohibited within 1.5 feet of grade on a street façade that is adjacent to a street lot line or sidewalk.

Ask a question about Milwaukee law

Corpus searches the Milwaukee sections it holds and shows the ones that match, with their citations. Free, no sign-in.