21A.28.040: NORTHPOINT LIGHT INDUSTRIAL ZONING DISTRICT (M-1A):
A. Purpose Statement: The purpose of the Northpoint District is to protect sensitive lands and wildlife habitat surrounding the Great Salt Lake shore lands and the Jordan River while providing an environment for light industrial, office, and research uses that produce minimal impact on adjacent residential and agricultural properties. This district is appropriate within the Northpoint Small Area Plan boundaries and other areas with similar attributes. The district promotes a high standard of building design quality, open space preservation, and protection of sensitive lands and waterways.
B. Uses: Uses in the Northpoint District as specified in Section 21A.33.040, "Table Of Permitted And Conditional Uses For Manufacturing Districts", of this title are permitted subject to the general provisions set forth in Section 21A.28.010.
C. Maximum Lot Area: The maximum allowable lot size is 10 acres. Approval for lots larger than 10 acres may be granted per Subsection 21A.28.040.I.
D. Minimum Yard and Setback Requirements:
1. Front Yard: 20'
2. Corner Side Yard: 20'
3. Interior Side Yard: 15'
4. Rear Yard: 15'
5. Additional Setback:
a. Principal structures must be a minimum of 65' from principal residential structures on abutting properties.
b. Vehicle laneways used to access a development site must be a minimum of 30' from principal residential structures on abutting properties.
6. Buffer Yards:
a. The Jordan River shall have a 300' buffer from the annual high-water level (AHWL), as defined in Section 21A.34.130, to protect the riparian corridor. Unless otherwise specified below, the Jordan River buffer is subject to all rules and regulations in 21A.34.130: Riparian Corridor Overlay District.
(1) No-Disturbance Area: The first 100' of the buffer from the AHWL, nearest to the river, shall be designated as a no-disturbance area. Permitted uses in the no-disturbance area shall be subject to the uses in Area A in Table 21A.34.130-3: USES ALLOWED ON UNDEVELOPED LAND.
(2) Structure Limit Area: The area between 100' and 200' from the AHWL shall be designated as a structure limit area. Permitted uses in the structure limit area shall be subject to the uses in Area B in Table 21A.34.120-2: USES ALLOWED ON DEVELOPED LOTS.
(3) Buffer Transition Area: The area between 200' and 300' from the AHWL shall be designated as the buffer transition area. Permitted uses in the buffer transition area shall be subject to the uses in Area C in Table 21A.34.130-2: USES ALLOWED BY AREA ON DEVELOPED LOTS.
E. Maximum Height: No building shall exceed 40 feet in height. Building height along loading dock areas may exceed the maximum height limit by 5 feet. The additional height shall only be allowed below the average elevation of finished grade and the area shall be excluded from the calculation of the average elevation of finished grade.
[image omitted; see the official code]
F. Building Size Limits: Building footprints are limited to a maximum of 100,000 square feet. The maximum footprint of a building may be increased per Subsection 21A.28.040.I.
G. Landscaping Requirements: The purpose of the landscaping in the Northpoint area is to provide appropriate native landscaping that prevents noxious weeds and to provide landscaping that will not negatively impact the adjacent sensitive lands.
1. All landscaping shall consist of native plants as identified in the "Salt Lake City Plant List and Hydrozone Schedule" on file with the planning division.
2. All required front, corner side, side, and rear yards shall be maintained as landscape yards in conformance with the requirements of Section 21A.48.060.C.
3. Trees are required along all property lines in the following yards:
a. Front and Corner Side Yards: One tree for every 30 linear feet of lot frontage. Trees may be spaced irregularly or clustered to form a natural grouping.
b. Interior Side and Rear Yards: One tree is required for every 30 linear feet of yard length. Trees may be spaced irregularly or clustered to form a natural grouping.
c. Interior Side and Rear Yards When Abutting a Residential Use: One tree is required for every 15 linear feet of the property line abutting the residential use. The zoning administrator may approve alternate planting locations for required trees to allow for clustering under the following conditions:
(1) No trees may be removed from any areas abutting or within 30 feet of a primary residential use; and
(2) The total number of required trees may not be reduced.
4. Noxious weed species as identified by the Utah Department of Agriculture and Food (or its successor) in the State of Utah Noxious Weed List (or its successor) shall be removed from landscaped areas and areas disturbed by construction activity. Noxious weeds shall be controlled for a period of two years and methods of control shall be identified on the landscape plan.
5. All other requirements in Chapter 21A.48 apply. This section shall take precedence in the case of a conflict with Chapter 21A.48.
H. Design Standards:
1. Maximum Building Façade Length along 2200 West: The maximum building façade length along 2200 West is limited to 250 feet. The maximum building façade length may be increased per Subsection 21A.28.040.I.
2. Blank Walls: The maximum length of any blank wall uninterrupted by windows, doors, art, or architectural detailing along any ground level street facing facade is 25'. Changes in plane, texture, materials, scale of materials, patterns, art, or other architectural detailing are acceptable methods to comply with this standard. The architectural feature shall be either recessed a minimum of twelve inches (12") or projected a minimum of twelve inches (12").
3. Building Materials: To mitigate the contrast of the built and natural environment, the following building materials are permitted: brick, natural stone, wood, and painted, tinted, or textured concrete. Stucco, including EIFS, is limited to architectural detailing surfaces and articulation. Exterior plastic vinyl siding or any reflective or polished materials are prohibited. Other materials not specifically mentioned may be permitted, on a case-by-case basis, with approval from the planning director, provided they meet the intent to mitigate the contrast and impact of the materials on the natural environment. Windows and doors are not subject to the building material restrictions.
4. Roofs: Light reflective roofing material with a minimum solar reflective index (SRI) of 82 shall be used for all roofs.
5. Glass: For any building elevation with more than 10% glass, a minimum of 90% of all glass shall be treated with applied films, coatings, tints, exterior screens, netting, fritting, frosted glass, or other means to reduce the number of birds that may collide with the glazing. Any treatment must create a grid pattern that is equal to or smaller than 2 inches wide by 4 inches tall. Mirrored or highly reflective glass is prohibited.
6. Lighting:
a. All lighting, including lighting on buildings, parking areas, and signs shall be shielded to direct light down and away from the edges of the property to eliminate glare or light encroaching onto adjacent properties and have cutoffs so that no light is emitted and/or reflected above the horizontal plane of the fixture. When a light manufacturer provides a BUG rating, the uplight rating (U) shall equal zero (0).
b. Uplighting and event searchlights are prohibited.
c. Total site illumination shall not exceed 100,000 lumens per net acre.
d. Outdoor lighting shall be a color temperature of 3,000 Kelvin or less.
7. Fencing: To minimize impacts on wildlife, fences shall have a visually open design with at least 50% of the fence open for the continuous length of the fence. Fencing that is less than 50% open is permitted when solid screening is otherwise required by this title.
a. Prohibited Decorative Features:
(1) Pointed extensions at the top of fences are prohibited to prevent injury to wildlife attempting to traverse the fence.
(2) Woven wire fencing and incorporating loose wires that may entangle animals is prohibited to avoid harm to wildlife.
(3) Hollow fence posts that are open at the top, where birds or other small animals may become entrapped, are prohibited. All fence posts must be solid or have caps securely attached.
8. Stormwater Management:
a. This subsection shall be enforced by the Salt Lake City Public Utilities Department.
b. Drainage: Site stormwater shall be collected on site and routed to the public storm drain system or gutter. Stormwater may not discharge across property lines or across public sidewalks without legal authorization to do so. A technical drainage study is required for the development of all lots detailing compliance with the requirements of this section to be reviewed with any site development or building permit.
c. Stormwater Quality: Stormwater treatment is required prior to discharge to the public storm drain. Sites shall utilize stormwater best management practices (BMP's) to remove solids, oils, and other pollutants. Green infrastructure should be used whenever possible. Options for green infrastructure and low impact development include bioretention systems, harvest/reuse, permeable surfaces, green roofs, and site design.
d. Retention: Retention of the 80th percentile storm is required for all new and redevelopment projects greater than 1 acre.
e. Detention: Detention shall be provided to ensure stormwater discharge does not exceed 0.2 cfs per acre, or less, to match pre-development flows, as identified in the area stormwater master plan. Detention systems shall be designed using the 100-year 3-hour storm using the Farmer-Fletcher rainfall distribution.
I. Modifications of Standards: Modifications to the standards of this section are allowed as identified in this subsection:
1. Applicability. All development sites within the M-1A (Northpoint Light Industrial) zoning district. Development site includes all land under the same ownership that is proposed to be developed as one development area. Development sites can include land that contains multiple parcels or lots.
2. Restrictive Covenants: Development limitations elected in connection with modifying a development standard as set forth in this subsection shall be documented by a restrictive covenant in favor of the city recorded on the title of the development site that describes the area that is being voluntarily restricted to modify a zoning standard.
3. Land used to allow one modification may not be counted toward allowing another modification.
4. Allowed modifications:
a. Maximum Lot Area: Approval for lots larger than 10 acres may be granted, provided the buildings and structures are grouped and comply with the following standards:
(1) The cluster development shall be a minimum of 10 acres.
(2) A minimum separation of 15 feet shall be provided between all principal buildings.
(3) A minimum of 20% of the area of the lot to be modified is designated as natural open space on the development site, as defined in Section 21A.62.040. Natural open space shall, to the greatest extent possible, be contiguous. Fragmented and disconnected small areas scattered throughout the development site including required building separations, and required setback yards, shall not count toward the 20%. Any required wetland, canal, or riparian buffers may be counted toward the 20%,
b. Maximum Building Façade Length: The maximum building façade length along 2200 West may be increased if natural open space in excess of any required buffer is provided on the development site. The maximum building façade length may increase by 20 feet if 5% of the total non-buffer area of the site is dedicated as natural open space, as defined in Section 21A.62.040, and may increase by an additional 20 feet for every additional 5%. The natural open space dedicated and permanently protected on site shall be no less than 7,000 SF and shall, to the greatest extent possible, be contiguous. Fragmented and disconnected small areas scattered throughout the development site, and required setback yards, shall not be counted.
c. Maximum Building Footprint Size: The maximum footprint of a building may be increased by complying with one or more of the options below. No more than an additional 100,000 square feet in building footprint will be permitted:
| Option | Amount of additional building square footage
| Option | Amount of additional building square footage
1. | Electric Vehicle Parking: Provide a minimum of 10 electric vehicle parking spaces on the development site. 1 ADA electric vehicle stall shall be provided for every 25 electric vehicle stalls Electric vehicle parking spaces shall count toward the minimum required number of parking spaces. The electric vehicle parking space shall be: a. Located in the same lot as the principal use; b. Signed in a clear and conspicuous manner, such as special pavement marking or signage, indicating exclusive availability to electric vehicles; and c. Outfitted with a standard electric vehicle charging station. | 10,000 SF per 10 parking stalls
2. | At least 30% of the roof area of the building seeking an increase in footprint shall be devoted to either solar panels or a vegetated green roof, or a combination of the two. | 40,000 SF
3. | Designation of natural open space within the development site, as defined in Section 21A.62.040. Natural open space shall, to the greatest extent possible, be contiguous. Fragmented and disconnected small areas scattered throughout the development, and required setback yards, shall not count towards the designated open space. Jordan River Transitional Buffer Area and Wetland Buffers: Land within the Transitional Buffer Area or any required wetland buffers may count as natural open space. The square footage increase shall be for a building outside of the required buffer area on the same development site and shall include item #4 below (Inclusion of a privately-owned public pathway, trail, or greenway connecting to or through natural open space areas). | 1 SF per 1 SF of natural open space
4. | Inclusion of a privately-owned public pathway, trail, or greenway connecting to or through natural open space areas. | 10,000 SF per 1,000 linear feet of trail25,000 SF per trailhead. The trailhead must include amenities such as directional signage, benches, etc.
5. | Providing full retention of site stormwater with no release to the public storm drain system and providing enhanced stormwater quality practices. System design to be approved by the Salt Lake City Public Utilities Department. | 50,000 SF
6. | Providing detention to the effect that no more than 0.1 cfs/acre is discharged for the 100-year 3-hour storm with the Farmer Fletcher Rainfall Distribution and providing enhanced stormwater quality practices. System design to be approved by the Salt Lake City Public Utilities Department. | 35,000 SF
7. | The site is developed as an all-electric property. All-electric property means a property that contains no permanently installed equipment or appliances that utilize combustion, plumbing for fuel gas or fuel oil or fuel gas utility connection, installed within the building(s) or site, except for emergency power systems and standby power systems. | 50,000 SF
(Ord. 3-25, 2025)