Sec. 28-57. - Deletions and amendments to the 2021 International Plumbing Code.
1. Section 101.1. is deleted in its entirety and replaced with the following:
101.1 Title. These regulations shall be known as the Plumbing Code of the City of Denton, hereinafter referred to as "this code."
2. Section 103.1 is deleted in its entirety and replaced with the following:
103.1 Creation of agency. The Building Safety Department is hereby created and the executive official in charge thereof shall be known as the code official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code.
3. Section 106.5.3 is deleted in its entirety and replaced with the following:
106.5.3 Expiration. Every permit issued by the code official under the provisions of this code shall expire by limitation and become null and void if the work authorized by such permit is not commenced within 180 days from the date of such permit, or is suspended or abandoned at any time after the work is commenced for a period of 180 days.
3. Section 109.2 is deleted in its entirety and replaced with the following:
109.2 Schedule of permit fees. Where a permit is required, a fee for each permit shall be paid as required, in accordance with the schedule as established by the applicable governing authority or ordinance of the City.
4. Section 109.3 is deleted in its entirety and replaced with the following:
109.3 Work commencing before permit issuance. Any person who commences work requiring a permit on a building, structure, electrical, gas, mechanical or plumbing system before obtaining the necessary permits shall be subject to the required permit fees, as set by the current schedule of fees adopted by ordinance of the City.
5. Section 112.2 is deleted in its entirety and replaced with the following:
112.2 Required inspections and testing. The code official, upon notification from the permit holder or the permit holder's agent, shall make the following inspections and such other inspections as necessary, and shall either release that portion of the construction or shall notify the permit holder or an agent of any violations that must be corrected. The holder of the permit shall be responsible for the scheduling of such inspections.
1. Underground inspection shall be made after trenches or ditches are excavated and bedded, piping installed, and before any backfill is put in place. This shall include testing of the underground plumbing.
2. Rough-in inspection shall be made after the roof, framing, fireblocking, firestopping, draftstopping and bracing is in place and all sanitary, storm and water distribution piping is roughed-in, and prior to the installation of wall or ceiling membranes. This shall include testing of the underground plumbing.
3. Final inspection shall be made after the building is complete, all plumbing fixtures are in place and properly connected, and the structure is ready for occupancy. This shall include testing of the underground plumbing.
6. Section 113 Means of Appeals, is deleted in its entirety and replaced with the following:
R113 HEALTH AND BUILDING STANDARDS COMMISSION
R113.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the building official, code official, or fire marshal relative to the application and interpretation of the requirements of this Code and all other applicable codes of the City of Denton, there shall be a health and building standards commission.
R113.2 Limitations on authority. An application for appeal shall be based on a claim that the true intent of this code or the rules legally adopted thereunder have been incorrectly interpreted, the provisions of this code do not fully apply or an equally good or better form of construction is proposed. The health and building standards commission shall not have authority to waive requirements of this code.
7. Section 115.4, Violation Penalties, is deleted in its entirety.
8. Section 305.4.1 Sewer depth, is deleted in its entirety and replaced with the following:
305.4.1 Sewer depth. Building sewers that connect to private sewage disposal systems shall be installed not less than twelve (12) inches (304.8 mm) below finished grade at the point of septic tank connection Building sewers shall be installed not less than twelve (12) inches (304.8 mm) below grade.
9. The following language is hereby added to Section 502.3 as a second paragraph:
As a minimum, for access to the attic space, one of the following shall be provided:
1. A permanent stair.
2. A pull-down stair with a minimum 300 lb. (136 kg) capacity.
3. An access door from an upper floor level.
10. Section 903.1.1 is deleted in its entirety and replaced with the following:
903.1.1 Roof extension unprotected. Open vent pipes that extend through a roof shall be terminated not less than six (6) inches (152 mm) above the roof.
(Ord. No. 22-666, § 1, 4-5-22)