25-36 Rainwater leaders.
(a) In areas serviced by separated sewers, all rainwater leaders, sump pumps and foundation drains shall connect to the separate storm sewer system. In areas serviced by separated sewers, all rainwater leaders and foundation drains shall connect to a separate storm sewer system. In areas serviced by combined sewers, approval for connection shall be required from the city engineer or duly authorized waste water official and is contingent upon a determination of sufficient capacity in the collection and treatment system. (b) No roofs, paved areas, yards, courts or courtyards shall be connected directly to a foundation drain system. Any connection made to the foundation drain line shall be made on the outlet side of the drain line at a minimum distance of ten (10) feet downstream from the foundation drain system. Such connections shall be made with long sweep connectors and approved by the plumbing inspector prior to installation.
(Ord. of 10-24-88; Ord. of 9-26-94; Ord. of 1-22-18(2))