For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 63.228 — Site Improvements, Utilities and Limitations

Code of the City of Orlando (Supp. No. 93, Update 1: codified through Ordinance No. 2026-10, adopted April 6, 2026) · Orlando City Code § 63.228

Corpus is an independent public-information project, not the official City of Orlando website. Stable reference: corpuslaw.us/code/abf3d522-67cb-4c3b-9957-76154f623840

Sec. 63.228. - Site Improvements, Utilities and Limitations.

(a) Minimum requirements. All proposed new development shall be reviewed to determine that: 1. Such proposals are consistent with the need to minimize flood damage and will be reasonably safe from flooding; 2. All public utilities and facilities such as sewer, gas, electric, communications, and water systems are located and constructed to minimize or eliminate flood damage and designed for the subsidence hazard; and 3. Adequate drainage is provided to reduce exposure to flood hazards; in Zones AH and AO, adequate drainage paths shall be provided to guide floodwaters around and away from proposed structures. (b) Sanitary sewage facilities. All new and replacement sanitary sewage facilities, and private sewage treatment plants (including all pumping stations and collector systems), shall be designed in accordance with Chapter 64E-6, F.A.C. and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the facilities and discharge from the facilities into flood waters, and impairment of the facilities and systems. Installation of new septic systems in special flood hazard areas is prohibited. (c) Water supply facilities. All new and replacement water supply facilities shall be designed in accordance with the water well construction standards in Chapter 62-532.500, F.A.C. and ASCE 24 Chapter 7 to minimize or eliminate infiltration of floodwaters into the systems. New water wells shall be protected to the one foot above the base flood elevation or the regulatory flood elevation for closed basin lakes. Water wells to be abandoned shall be capped and sealed. (d) Limitations on stream encroachments. In special flood hazard areas without base flood elevations, or in special flood hazard areas with base flood elevations but without floodway designations, no encroachments, including fill material or structures, shall be located within a distance of a stream bank equal to five times the width of the stream at the top of bank or twenty (20) feet on either side from top of bank, whichever is greater. (e) Limitations on sites in regulatory floodways. No development, including but not limited to site improvements, and land disturbing activity involving fill or regrading, shall be authorized in the regulatory floodway unless the floodway encroachment analysis required in Section 63.223(c).1 of this Part demonstrates that the proposed development or land disturbing activity will not result in any increase in the base flood elevation. (f) Limitations on placement of fill. Subject to the limitations of this Part, fill shall be designed to be stable under conditions of flooding including rapid rise and rapid drawdown of floodwaters, prolonged inundation, and protection against flood-related erosion and scour. In addition to these requirements, if intended to support buildings and structures (Zone A only), fill shall comply with the requirements of the Florida Building Code. (g) Building elevation and drainage. At all locations in the City, including outside of mapped special flood hazard areas: 1. For buildings, lowest floors shall be at or above eighteen (18) inches above the crown of the nearest street or the elevation required by the Florida Building Code, whichever is higher. 2. Site plans for new buildings shall account for drainage from adjacent streets and adjacent properties, and shall show positive drainage away from buildings to approved points of collection without creating a hazard or drainage problem on adjacent properties. (h) Vehicle access and streets. Unless otherwise approved by the Floodplain Administrator: 1. Vehicle access to dry land above the base flood elevation shall be provided for new multi-family buildings and new commercial buildings located in flood hazard areas. 2. New streets in flood hazard areas shall have the driving surface not less than one (1) foot below the base flood elevation. (i) Compensating storage. Compensating storage shall be provided for fill placed in special flood hazard areas in accordance with the City of Orlando Engineering Standards Manual.

(Ord. No. 2018-27, § 2, 5-29-2018, Doc. #1805291205; Ord. No. 2021-66, § 1, 11-8-2021, Doc. #2111081204)

Ask a question about Orlando law

Corpus searches the Orlando sections it holds and shows the ones that match, with their citations. Free, no sign-in.