BC 2306 — Allowable Stress Design
New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Building Code § BC 2306
Corpus is an independent public-information project, not the official City of New York website. Stable reference: corpuslaw.us/code/ad09f542-66b2-4407-8c39-ba81aec13cd3
Section BC 2306: Allowable Stress Design
2306.1 Allowable stress design. The design and construction of wood elements in structures using allowable design methods shall be in accordance with the following applicable standards: American Wood Council. ANSI/AWC NDS National Design Specification for Wood Construction ANSI/AWC SDPWS Special Design Provisions for Wind and Seismic American Society of Agricultural and Biological Engineers. ASABE EP 484.3 Diaphragm Design of Metal-clad, Wood-frame Rectangular Buildings ASABE EP 486.2 Shallow Post Foundation Design ASABE EP 559.1 Design Requirements and Bending Properties for Mechanically Laminated Wood Assemblies APA – The Engineered Wood Association. ANSI 117 Standard Specifications for Structural Glued Laminated Timber of Softwood Species ANSI A190.1 Structural Glued Laminated Timber Panel Design Specification Plywood Design Specification Supplement 1 - Design & Fabrication of Plywood Curved Panel Plywood Design Specification Supplement 2 - Design & Fabrication of Glued Plywood-lumber Beams Plywood Design Specification Supplement 3 - Design & Fabrication of Plywood Stressed-skin Panels Plywood Design Specification Supplement 4 - Design & Fabrication of Plywood Sandwich Panels Plywood Design Specification Supplement 5 - Design & Fabrication of All-plywood Beams APA T300 Glulam Connection Details APA S560 Field Notching and Drilling of Glued Laminated Timber Beams APA S475 Glued Laminated Beam Design Tables APA X440 Product and Application Guide: Glulam APA R540 Builders Tips: Proper Storage and Handling of Glulam Beams Truss Plate Institute, Inc. TPI 1 National Design Standard for Metal Plate Connected Wood Truss Construction West Coast Lumber Inspection Bureau AITC 104 Typical Construction Details AITC 110 Standard Appearance Grades for Structural Glued Laminated Timber AITC 113 Standard for Dimensions of Structural Glued Laminated Timber AITC 119 Standard Specifications for Structural Glued Laminated Timber of Hardwood Species AITC 200 Inspection Manual (Am. L.L. 2023/077, 6/11/2023, eff. 6/11/2023) Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2023/077. 2306.1.1 Joists and rafters. The design of rafter spans is permitted to be in accordance with the AWC STJR. 2306.1.2 Plank and beam flooring. The design of plank and beam flooring is permitted to be in accordance with the AWC Wood Construction Data No. 4. 2306.1.3 Treated wood stress adjustments. The allowable unit stresses for preservative-treated wood shall be adjusted for treatment in accordance with the ANSI/AWC NDS. The allowable unit stresses for fire-retardant-treated wood, including fastener values, shall be developed from an approved method of investigation that considers the effects of anticipated temperature and humidity to which the fire-retardant-treated wood will be subjected, the type of treatment and the redrying process. Other adjustments are applicable except that the impact load duration shall not apply. 2306.1.4 Lumber decking. The capacity of lumber decking arranged according to the patterns described in Section 2304.9.2 shall be the lesser of the capacities determined for flexure and deflection according to the formulas in Table 2306.1.4. Table 2306.1.4 Allowable Loads for Lumber Decking Pattern Allowable Area Load a, b Flexure Deflection Simple span   Two-span continuous   Combination simple- and two-span continuous   Cantilevered pieces intermixed   Controlled random layup Mechanically laminated decking   2-inch decking   3-inch and 4-inch decking   For SI: 1 inch = 25.4 mm. a. σb = Allowable total uniform load limited by bending. σΔ = Allowable total uniform load limited by deflection. b. d = Actual decking thickness. L = Span of decking. F'b = Allowable bending stress adjusted by applicable factors. E' = Modulus of elasticity adjusted by applicable factors. 2306.2 Wood-frame diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall be permitted. The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design. Table 2306.2(1) Allowable Shear Values (Pounds per Foot) for Wood Structural Panel Diaphragms Utilizing Staples with Framing of Douglas Fir-Larch, or Southern Pine a for Wind or Seismic Loading f Panel Grade Staple Length and Gaged Minimum Fastener Penetration in Framing (inches) Minimum Nominal Panel Thickness (inch) Minimum Nominal Width of Framing Members at Adjoining Panel Edges and Boundaries e (inches) Blocked Diaphragms Unblocked Diaphragms Fastener spacing (inches) at diaphragm boundaries (all cases) at continuous panel edges parallel to load (Cases 3,4), and at all panel edges (Cases 5,6) b Fasteners spaced 6 max. at supported edges b 6 4 2 1/2 c 2 c Case 1 (No unblocked edges or continuous joints parallel to load) All other configurations (Cases 2, 3, 4, 5 and 6) Fastener spacing (inches) at other panel edges (Cases 1, 2, 3 and 4) b 6 6 4 3 Structural I grades 1 1/2 16 Gage 1 3/8 2 175 235 350 400 155 115 3 200 265 395 450 175 130 15/32 2 175 235 350 400 155 120 3 200 265 395 450 175 130 Sheathing, single floor and other grades covered in DOC PS 1 and PS 2 1 1/2 16 Gage 1 3/8 2 160 210 315 360 140 105 3 180 235 355 400 160 120 7/16 2 165 225 335 380 150 110 3 190 250 375 435 165 125 15/32 2 160 210 315 360 140 105 3 180 235 355 405 160 120 19/32 2 175 235 350 400 155 115 3 200 265 395 450 175 130  For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of lumber in ANSI/AWC NDS. (2) For staples, find shear value from table above for Structural I panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Space fasteners maximum 12 inches on center along intermediate framing members (6 inches on center where supports are spaced 48 inches on center). c. Framing at adjoining panel edges shall be 3 inches nominal or wider. d. Staples shall have a minimum crown width of 7/16 inch and shall be installed with their crowns parallel to the long dimension of the framing members. e. The minimum nominal width of framing members not located at boundaries or adjoining panel edges shall be 2 inches. f. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table above shall be multiplied by 0.63 or 0.56, respectively. Table 2306.2(2) Allowable Shear Values (pounds per foot) for Wood Structural Panel Blocked Diaphragms Utilizing Multiple Rows of Staples (High-Load Diaphragms) with Framing of Douglas Fir-Larch or Southern Pine a for Wind or Seismic Loading b, g, h Panel Grade Staple Gage f Minimum Fastener Penetration in Framing (inches) Minimum Nominal Panel Thickness (inch) Minimum Nominal Width of Framing Members at Adjoining Panel Edges and Boundaries e Lines of Fasteners Blocked Diaphragms Cases 1 and 2 d Fastener Spacing Per Line at Boundaries (inches) 4 2 1/2 2 Fastener Spacing Per Line at Other Panel Edges (inches) 6 4 4 3 3 2 Structural I grades 14 Gage Staples 2 15/32 3 2 600 600 860 960 1,060 1,200 4 3 860 900 1,160 1,295 1,295 1,400 19/32 3 2 600 600 875 960 1,075 1,200 4 3 875 900 1,175 1,440 1,475 1,795 Sheathing, single floor and other grades covered in DOC PS 1 and PS 2 14 Gage Staples 2 15/32 3 2 540 540 735 865 915 1,080 4 3 735 810 1,005 1,105 1,105 1,195 19/32 3 2 600 600 865 960 1,065 1,200 4 3 865 900 1,130 1,430 1,370 1,485 23/32 4 3 865 900 1,130 1,490 1,430 1,545 For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of framing lumber in ANSI/AWC NDS. (2) For staples, find shear value from table above for Structural I panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Fastening along intermediate framing members: Space fasteners not greater than 12 inches on center, except 6 inches on center for spans greater than 32 inches. c. Panels conforming to PS 1 or PS 2. d. This table gives shear values for Cases 1 and 2 as shown in Table 2306.2(1). The values shown are applicable to Cases 3, 4, 5 and 6 as shown in Table 2306.2(1), providing fasteners at all continuous panel edges are spaced in accordance with the boundary fastener spacing. e. The minimum nominal depth of framing members shall be 3 inches nominal. The minimum nominal width of framing members not located at boundaries or adjoining panel edges shall be 2 inches. f. Staples shall have a minimum crown width of 7/16 inch, and shall be installed with their crowns parallel to the long dimension of the framing members. g. High-load diaphragms shall be subject to special inspection in accordance with Section 1705.5.1. h. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table above shall be multiplied by 0.63 or 0.56, respectively.  (Am. L.L. 2023/077, 6/11/2023, eff. 6/11/2023) Editor's note: For related unconsolidated provisions, see Appendix A at L.L. 2023/077. 2306.2.1 Gypsum board diaphragm ceilings. Gypsum board diaphragm ceilings shall be in accordance with Section 2508.5. 2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with AWC SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AWC SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall be permitted. The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AWC SDPWS. Table 2306.3(1) Allowable Shear Values (pounds per foot) for Wood Structural Panel Shear Walls Utilizing Staples with Framing of Douglas Fir-Larch or Southern Pine a for Wind or Seismic Loading b, f, g, i Panel Grade Minimum Nominal Panel Thickness (inch) Minimum Fastener Penetration in Framing (inches) Panels Applied Direct to Framing Panels Applied over 1/2" or 5/8" Gypsum Sheathing Staple length and gage (inches) h Fastener spacing at panel edges (inches) Staple length and gage (inches) h Fastener spacing at panel edges (inches) 6 4 3 2 d 6 4 3 2 d Structural I grades 3/8 1 1 1/2 16 Gage 155 235 315 400 2 16 Gage 155 235 310 400 7/16 170 260 345 440 155 235 310 400 15/32 185 280 375 475 155 235 300 400 Sheathing, plywood siding e except Group 5 Species 5/16 c or 1/4 c 1 1 1/2 16 Gage 145 220 295 375 2 16 Gage 110 165 220 285 3/8 140 210 280 360 140 210 280 360 7/16 155 230 310 395 140 210 280 360 15/32 170 255 335 430 140 210 280 360 19/32 1 3/4 16 Gage 185 280 375 475 – – – – – For SI: 1 inch = 25.4 mm, 1 pound per foot = 14.5939 N/m. a. For framing of other species: (1) Find specific gravity for species of lumber in ANSI/AWC NDS. (2) For staples, find shear value from table above for Structural I panels (regardless of actual grade) and multiply value by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. b. Panel edges backed with 2-inch nominal or wider framing. Install panels either horizontally or vertically. Space fasteners maximum 6 inches on center along intermediate framing members for 3/8-inch and 7/16-inch panels installed on studs spaced 24 inches on center. For other conditions and panel thickness, space fasteners maximum 12 inches on center on intermediate supports. c. 3/8-inch panel thickness or siding with a span rating of 16 inches on center is the minimum recommended where applied directly to framing as exterior siding. For grooved panel siding, the nominal panel thickness is the thickness of the panel measured at the point of fastening. d. Framing at adjoining panel edges shall be 3 inches nominal or wider. e. Values apply to all-veneer plywood. Thickness at point of fastening on panel edges governs shear values. f. Where panels are applied on both faces of a wall and fastener spacing is less than 6 inches on center on either side, panel joints shall be offset to fall on different framing members, or framing shall be 3 inches nominal or thicker at adjoining panel edges. g. In Seismic Design Category D where shear design values exceed 350 pounds per linear foot, all framing members receiving edge fastening from abutting panels shall be not less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See AWC SDPWS for sill plate size and anchorage requirements. h. Staples shall have a minimum crown width of 7/16-inch and shall be installed with their crowns parallel to the long dimension of the framing members. i. For shear loads of normal or permanent load duration as defined by the ANSI/AWC NDS, the values in the table above shall be multiplied by 0.63 or 0.56, respectively. Table 2306.3(2) Allowable Shear Values (Plf) for Wind or Seismic Loading on Shear Walls of Fiberboard Sheathing Board Construction Utilizing Staples for Type V Construction Only a, b, c, d, e Thickness and Grade (inches) Staple Gage and Dimensions Allowable Shear Value (pounds per linear foot) Staple Spacing at Panel Edges (inches) a 4 3 2 1/2" or 25/32" Structural No. 16 gage galvanized staple, 7/16 inch crown 1 3/4 inch long 150 200 225 No. 16 gage galvanized staple, 1 inch crown 1 3/4 inch long 220 290 325 For SI: 1 inch = 25.4 mm, 1 pound per linear foot = 14.5939 N/m. a. Fiberboard sheathing shall not be used to brace concrete or masonry walls. b. Panel edges shall be backed with 2-inch or wider framing of Douglas Fir-larch or Southern Pine. For framing of other species: (1) Find specific gravity for species of framing lumber in ANSI/AWC NDS. (2) For staples, multiply the shear value from the table above by 0.82 for species with specific gravity of 0.42 or greater, or 0.65 for all other species. c. Values shown are for fiberboard sheathing on one side only with long panel dimension either parallel or perpendicular to studs. d. Fastener shall be spaced 6 inches on center along intermediate framing members. e. Values are not permitted in Seismic Design Category D. Table 2306.3(3) Allowable Shear Values for Wind or Seismic Forces for Shear Walls of Lath and Plaster or Gypsum Board Wood Framed Wall Assemblies Utilizing Staples Type of Material Thickness of Material Wall Construction Staple Spacing b Maximum (inches) Shear Value a, c (plf) Minimum Staple Size f, g 1. Expanded metal or woven wire lath and portland cement plaster 7/8" Unblocked 6 180 No. 16 gage galv. staple, 7/8" legs 2. Gypsum lath, plain or perforated 3/8" lath and 1/2" plaster Unblocked 5 100 No. 16 gage galv. staple, 1 1/8" long 3. Gypsum sheeting 1/2" × 2' × 8' Unblocked 4 75 No. 16 gage galv. staple, 1 3/4" long 1/2" × 4' Blocked d 4 175 Unblocked 7 100 4. Gypsum board, gypsum veneer base or water-resistant gypsum backing board 1/2" Unblocked d 7 75 No. 16 gage galv. staple, 1 1/2" long Unblocked d 4 110 Unblocked 7 100 Unblocked 4 125 Blocked e 7 125 Blocked e 4 150 5/8" Unblocked d 7 115 No. 16 gage galv. staple, 1 1/2" legs, 1 5/8" long 4 145 Blocked e 7 145 4 175 Blocked e Two-ply Base ply: 9 Face ply: 7 250 No. 16 gage galv. staple, 1 5/8" long No. 15 gage galv. staple, 2 1/4" long For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per foot = 14.5939 N/m. a. These shear walls shall not be used to resist loads imposed by masonry or concrete walls (see AWC SDPWS). Values shown are for short-term loading due to wind or seismic loading. Walls resisting seismic loads shall be subject to the limitations in Section 12.2.1 of ASCE 7. Values shown shall be reduced 25 percent for normal loading. b. Applies to fastening at studs, top and bottom plates and blocking. c. Except as noted, shear values are based on a maximum framing spacing of 16 inches on center. d. Maximum framing spacing of 24 inches on center. \e. All edges are blocked, and edge fastening is provided at all supports and all panel edges. f. Staples shall have a minimum crown width of 7/16 inch, measured outside the legs, and shall be installed with their crowns parallel to the long dimension of the framing members. g. Staples for the attachment of gypsum lath and woven-wire lath shall have a minimum crown width of 3/4 inch, measured outside the legs.
Ask a question about New York law
Corpus searches the New York sections it holds and shows the ones that match, with their citations. Free, no sign-in.
