For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-234 — Standards of fitness

Code of Ordinances, City of Durham, North Carolina (Supp. No. 37, Update 1: codified through Ordinance No. 16682, adopted June 15, 2026) · Durham City Code § 10-234

Corpus is an independent public-information project, not the official City of Durham website. Stable reference: corpuslaw.us/code/ad14f56f-9280-4ad1-a1c5-296262ec6f18

Sec. 10-234. - Standards of fitness.

(a) Space and use standards. (1) Contents of dwelling unit. Every dwelling unit shall contain the following: a. A principal room of not less than 120 square feet; b. A bathroom that affords privacy and contains a toilet, lavatory and either a tub or shower; c. A habitable room, including all bedrooms, shall not be less than seven feet in any plan dimension, have at least 70 square feet and shall have a clear ceiling height of not less than seven feet. Minimum area and dimension requirements shall not apply to kitchen areas; d. At least 150 square feet of floor area in habitable rooms for the first occupant, at least 100 square feet for each additional occupant. The floor area shall be calculated on the basis of the total floor area of the dwelling unit, exclusive of stairways. For the purpose of such calculation, only the floor area in a basement meeting the requirements for basement occupancy shall be counted. e. A closet or storage space, such as an armoire or wardrobe, suitable for clothing and personal belongings, providing a minimum storage area of 20 cubic feet. (2) Kitchen and kitchen facilities. a. Every dwelling unit shall contain a room or space for the preparation and cooking of food which shall include space and connections for a stove or other cooking facilities, space for dry food storage and space for refrigerated food storage and a kitchen sink. b. The use of gasoline stoves or other similar fuel burning appliances using highly flammable liquids and the use of portable kerosene stoves or other similar fuel burning portable appliances for cooking are prohibited. c. Hoods and ducts over kitchen ranges shall be cleaned to remove grease or other flammable materials. The owner shall provide a clean hood fan and the occupant is responsible for the cleaning of the hood fan during occupancy. d. All fuel burning appliances shall be properly vented to the outside. (3) Basement occupancy. No room in any basement shall be occupied as a habitable room, bathroom or toilet room unless: a. There are no pipes, ducts or other obstructions to a walk area less than six feet above the floor level or less than five feet eight inches above the floor level in a bathroom or toilet room existing on the effective date of this article, and ceiling heights are in accordance with this article, except that a bathroom existing on the effective date of this article with at least one-half of the floor area having a ceiling height of not less than six feet six inches shall be permitted to continue; b. Light and ventilation for habitable rooms are provided in accordance with this article and 70 percent of the regular window area is above the ground level, except when window areaways or window wells are provided so that the minimum width of the areaway or well is not less than twice the distance from the bottom of the window to the finished grade; and c. The floor and walls, if in contact with the earth, are waterproof and dampproof in accordance with an acceptable method that assures that the damp proofing and water proofing continues to be effective. (4) Passing through bathrooms. Each dwelling unit shall be provided with a means of circulation giving access to all rooms without passing through a bathroom; but any passage through a bathroom existing at the time of the effective date of this article may be continued. (5) Doors. Doors shall be provided at all doorways leading to bedrooms, bathrooms and all rooms adjoining a public area. (6) Prohibited uses. Kitchen and non-habitable or public spaces shall not be used for sleeping purposes. No cellar space shall be used as a habitable space. (b) Entrances and exits. (1) All entrances and exits must meet the applicable standards set forth in the North Carolina State Building Code. (2) All entrances and exits shall be weather tight, and in good repair including door, frame, seals, casing, and all other door assembly and entry components. (3) Doors providing entrance and exit for any dwelling unit shall have locking devices capable of being operated from the inside and outside of the dwelling. Barrel bolts and hasps with padlocks are not adequate for exit doors. Locks with interior keyed deadbolts are prohibited on exit doors. Locking devices are not required for screen, storm, louver, or other secondary exit doors. (4) A safe, continuous, unobstructed path of travel shall be provided from all habitable areas of a dwelling or dwelling unit to the exterior at street or grade level. Clear passage shall not be obstructed by the placement, construction, and/or storage of any items or materials. Doors shall be capable of opening to 90 degrees of door frame to allow for clear passage. (5) Platforms and steps shall be provided, where appropriate, to serve exits and shall be maintained in a safe condition. (6) In all multifamily dwellings, all exit signs required by the laws and ordinances of the city shall be provided and maintained so as to be clearly visible at all times when the building is occupied. (c) Light and ventilation standards. (1) Every habitable room in a dwelling or dwelling unit shall contain a window opening directly to the outside air and the total glass area of such window shall not be less than eight percent of the floor area of such room, provided that the administrator may approve such other arrangement as will adequately light and ventilate the room where provision for openable windows is not feasible. All window sashes shall be glazed and provided with suitable hardware including a locking mechanism and shall be made to open freely to the extent of not less than four percent of the floor area of such room. (2) When a window cannot be provided to open directly to the outside air, a ventilating system which is vented to the outside may be substituted for the required window area. A blind, bathroom or toilet room shall be provided with artificial light and mechanical ventilation. However, existing ventilating systems in bathrooms and toilet rooms which are functioning adequately may be permitted to remain. (3) All operable and openable windows shall be adequately screened or equipped with storm windows with screens included for protection against mosquitoes, flies, and other insects. Screens shall not be permanently fixed to the window frame or sash unless designed by the manufacturer. All operable or openable exterior doors shall have either a screen door or a screen-equipped storm door, and shall be equipped with a self-closing device. Exception: This requirement shall not apply to dwelling units containing a heating and air conditioning system providing the dwelling unit with year-round mechanical ventilation, including permanently installed systems which provide such mechanical ventilation for one or more rooms. This requirement shall apply to dwelling units equipped with window air conditioning units which are not permanently installed. (4) Window frames and glass shall be weather tight, with no broken seals, or cracked or broken glass. If, in the opinion of the administrator, certain cracked glass does not present a hazard or compromises weather tightness, a waiver of this provision may be granted. (5) Openable window area in each toilet room and bathroom shall be at least one and one-half square feet, unless served by other approved ventilation. (6) Every sleeping room, unless it has two exits, or one exit direct to the outside, shall have at least one window that can be opened without the use of tools, including burglar bars, to provide a clear opening which can remain open without support, and is not less than 16 inches in least dimension and 432 square inches in area, or if of fixed glass must be at least 24 inches by 24 inches, with the bottom of the opening not more than four feet above the floor. Required openable window area shall have fixed screens. (7) Clothes dryer exhaust systems shall be vented in accordance with the manufacturer's instruction. (8) Lighting of halls and stairs. Every common hallway and stairway in every multifamily dwelling shall be adequately lighted at all times with fixtures sufficient to provide at least three foot-candles of light at the floor or stair tread level at all times. Single family dwellings shall be supplied with conveniently located light switches controlling the lighting system which provides the illumination required herein and as to be turned on when needed. (d) Heating and cooling. (1) Heating facilities. Every dwelling and dwelling unit shall be provided with a heating unit which is properly designed, installed and balanced or adjusted, maintained in good and safe condition and which is capable of safely and adequately heating all habitable rooms, bathrooms and water compartments located therein to a temperature of 68°F (20°C) in all habitable rooms, bathrooms and toilets. The required room temperatures shall be measured three feet above the floor near the center of the room and two feet inward from the center of each exterior wall. All rooms may vary in temperature by as much as ten degrees Fahrenheit. Either central or space heating units designed for continuous use may be used. Portable or temporary space heaters are strictly prohibited as a primary source of heat, but may be used to supplement heating. (2) Central heating and hvac (heating, ventilation, and air conditioning) units. a. Every central heating or HVAC unit shall: 1. Have every duct, pipe or tube free of leaks and functioning properly to provide an adequate amount of heat or conditioned air to the intended place of delivery; 2. Be provided with proper seals between sections of hot air furnaces to prevent the escape of noxious fumes and gases into heat ducts; 3. Be properly connected to an electric circuit of adequate capacity in an approved manner if electrical power is required; and 4. Be provided with all required automatic or safety devices and be installed and operated in the manner required by the laws, ordinances and regulation of the city. b. All liquid fuel used to operate any central heating unit shall be stored in accordance with the city's fire prevention and building codes; c. All gas and oil heating equipment installed on the premises shall be listed by a testing laboratory and shall be installed, including proper ventilation, in accordance with the applicable provisions of the North Carolina State Building Code. (3) Space heating units. a. Every space heating unit shall: 1. Not use gasoline or other similar highly flammable liquid fuel; 2. Not be of portable type using solid, liquid or gaseous fuel; 3. Be properly connected according to the manufacturer's instructions on installation; 4. Be so located or protected as to prevent any overheating of adjacent combustible material; 5. If employing electricity, be connected to a circuit of adequate capacity in an approved manner; 6. Be provided with all required automatic or safety devices; and 7. Be installed under permit and be properly operated. b. A kerosene space heater which has its fuel piped to the heater from a remotely installed bulk tank shall be permissible under this section. Other portable kerosene space heaters are strictly prohibited as a primary source of heat. c. All unvented gas-fired heating units are strictly prohibited, as a primary source of heat. d. Ornamental gas logs may be installed in a fireplace provided that such installation is in compliance with the applicable portions of the North Carolina State Building Code. (4) Fireplaces and chimneys. The following standards and conditions shall be applicable to fireplaces and chimneys unless rendered inoperable: a. Chimneys shall be tight and safe, and capable of maintaining proper draft for carriage of combustion by-products to outside air. b. Chimneys shall be kept clean of soot and other debris. c. No holes shall be permitted in flue, except for necessary vent connections and cleanout doors. d. All existing hanging masonry chimneys shall be removed. e. Thimbles shall be grouted in tight. f. Thimbles shall be located high enough to provide proper draft for the heating appliances served thereby. g. Fireplaces may be used only for supplemental heat and not as the primary heating source for a dwelling. This section does not exclude the use of wood burning stoves or inserts as the primary heating source for a dwelling. h. The hearth and the hearth extension shall extend a minimum of 36 inches from the back of the firebox to the end of the hearth extension. The hearth extension shall extend at least 16 inches in front of and at least eight inches beyond each side of the fireplace opening. Where the fireplace opening is six square feet or larger, the hearth extension shall extend at least 20 inches in front of and at least 12 inches beyond each side of the fireplace opening. i. No combustible materials shall be permitted within seven inches of the top and seven inches of either side of the fireplace opening. j. Where fireplace is closed and converted to other use, there shall be masonry closure of face and proper lining, or vent installed in chimney where same does not exist. (e) Structure standards. (1) General requirements. a. Good repair and safe condition. Every building and all parts thereof used or occupied as a dwelling shall be kept in good repair, in safe condition and fit for human habitation. b. Quality of materials and workmanship. All materials shall be of similar design and similar quality and shall meet the applicable standards set forth in the North Carolina State Building Code. Plumbing, mechanical, and electrical components shall meet the applicable standards set forth in the North Carolina State Building Code. The quality of workmanship shall be based on standards generally accepted in the construction industry. c. Boarding of doors and windows. No structure or portion of a structure shall be permitted to have any door or window boarded, secured, or obstructed with wood, plywood or other opaque material, unless authorized by the administrator. The administrator shall establish a policy regarding securing a dwelling. (2) Foundation. a. Every dwelling unit shall be on firm ground. Foundation drainage shall be provided and maintained so as to prevent standing water or other conditions that contribute to mold. Crawlspaces shall be free of high-moisture conditions. b. Footings shall be sound with adequate bearing. c. All elements of the foundation, including structural members and masonry, shall be in good repair. An engineer's report indicating structural soundness satisfies this requirement. d. No piers shall be used for support in which the plumb line from top center falls outside the middle one-third of the base of the pier. (A plumb bob held firmly against the top of the pier and hanging down the sidewall indicates the vertical alignment.) e. No isolated masonry piers exceeding in height ten times the least dimension of pier shall be permitted. f. A crawl space access hole having a door shall be provided to any under floor space in all dwellings. The door shall be sound, in good repair, vermin proof, and able to be latched in a closed position. (3) Exterior walls and other structure components. a. All exterior surfaces shall be structurally sound, waterproof, weatherproof, and vermin proof. b. All exterior wall covering and finishes shall be weather tight with no holes, cracks or rotted boards which permit outside air or water to penetrate. c. Windows shall be easily openable, shall have panes without cracks or holes and the sash shall fit properly. d. All structure or load bearing walls, exterior or interior, shall not be bowed or out of plumb and shall be structurally sound. A report from licensed engineer indicating compliance with this provision satisfies this requirement. e. Studs shall provide sufficient support for sheathing or exterior finish. f. All exterior finishes and surfaces shall be free of visible deterioration or unsanitary conditions, or chronic or persistent excessive dampness or moisture. (4) Roofs. a. Roofing shall be provided to prevent the entrance of moisture and shall be maintained by renewal, repair, waterproofing or other suitable means. b. Gutters and downspouts, if installed, shall be provided to properly collect, conduct and discharge the water from the roof and away from the structure. c. Roofs shall be properly supported, and no rafters or other framing members shall be rotted, broken, deteriorated, sagging, or improperly supported at the ends. A report from a licensed engineer indicating compliance with this provision satisfies this requirement. d. Attics shall have ventilation that allows the movement of air to dissipate excessive heat buildup. Heat buildup is excessive if it causes deterioration of any structural member or roofing material. e. Sheathing shall not be rotted, loose or sagging excessively. f. Roof covering shall not be loose, have missing shingles or other damaged roofing components, nor have holes, leaks, or evidence of current leaks. g. Adequate flashing shall be provided at walls and chimneys in a manner that continues to be effective. h. Roofs shall be kept free of vegetation which compromises or otherwise damages the integrity of materials or function of the roof, roof overhang, fascia, soffit, gutters, or other portion of the roof structure. However, this section does not apply to properly functioning "living" or "green" roof systems approved through a city or county approval or permitting process. (5) Stairs steps and porches. a. Stairs and steps shall be free of holes, grooves and cracks large enough to constitute accident hazards. b. Handrails shall be provided on at least one side of stairways of four or more risers. c. No flight of stairs shall be settled out of its intended position or pulled away from supporting or adjacent members. A report from a licensed engineer indicating compliance with this provision satisfies this requirement. d. Stairs shall be strongly supported and supports shall not be rotting, sagging or deteriorated. A report from a licensed engineer indicating compliance with this provision satisfies this requirement. e. Stairs shall be plumb, level and treads shall be uniform in width, and risers shall be uniform in height, sound and securely fastened to structure. A slight uniform tilt of the treads to aid in the runoff of water is permissible for exterior steps. f. Every stairway, including inside stairs and rails, porches, decks and appurtenances thereto shall be kept in sound condition and good repair. g. Platforms and steps shall be provided to serve exits and shall be maintained in a safe condition. h. Guards shall be provided along open-sided walking surfaces, including stairs, ramps and landings where the distance from the surface to the grade is greater than 30 inches at any point within 36 inches horizontally to the edge of the open side. Newly installed guards shall meet current NC State Building Code standards. (6) Ceilings. a. Joists and supporting members shall provide sufficient support for the ceiling. b. No holes or cracks which permit outside air to penetrate rooms shall be permitted. c. There shall be no loose plaster, boards, sheetrock, or ceiling finish. Any materials used in the repair of the ceiling shall be of a material that is similar in texture and appearance to the original material. This provision does not prohibit the replacement of the entire ceiling; provided that the material used is contiguous over the entire ceiling area within the affected room. d. Ceilings shall be maintained free of holes, excessive cracks or loose or deteriorated materials. e. All ceilings shall be kept clean and free of any flaking, loose or peeling paint and paper. f. A minimum clear opening (attic access hole) into each attic space of 14 inches by 24 inches shall be provided to allow for access, inspection and repair. The administrator may grant a waiver of this requirement in cases where meeting this requirement would necessitate major alterations of the structure, or would produce harmful accumulations of heat or moisture that cannot be removed by ventilation. g. Every dwelling unit shall have a minimum of R-19 insulation in the attic area. The approved types include blown insulation, batt insulation or other insulation equivalent to a total of R-19 insulation value. (7) Interior walls. a. Interior finish shall be free of excessive holes and excessive cracks which: 1. Permit outside air or moisture to penetrate rooms; 2. Allow rodent or insect infiltration; or 3. Contain loose or flaking materials. b. All walls, woodwork, doors and windows shall be kept clean and free of any flaking, loose or peeling paint. c. There shall be no loose plaster, boards, or other loose or deteriorated wall materials. Walls shall be finished to industry standards. d. Cardboard, newspaper, other highly combustible materials, or other wall finishes that fail to provide a stable, permanent, and continuous protective surface are prohibited. e. Studs shall provide sufficient support for interior wall. f. Doors must fit the opening in which they are hung and be equipped with hardware that allows for their opening and closing. g. All interior surfaces and surface coverings, such as but not limited to wood, paint, and other wall coverings, including paper-faced gypsum board, shall be free of visible deterioration or unsanitary conditions, or chronic or persistent excessive dampness or moisture. (8) Floors. a. Broken, overloaded, excessively decayed or sagging structural floor members are prohibited. b. Structural floor members shall be supported on foundation walls and piers that are not deteriorated and perform the function for which they were intended. c. Floor joists shall be supported on structural bearing members and shall not be made structurally unsound by deterioration. d. Flooring shall be reasonably smooth, not rotten or worn through, and without holes or excessive cracks. e. Flooring and floor coverings, including carpeting, shall be installed and maintained so as to eliminate tripping or other physical hazards. f. Split, splintered or badly worn floorboards shall be repaired or replaced. g. Floors in contact with soil shall be paved either with concrete not less than three inches thick or with other masonry not less than four inches thick, which shall be sealed tightly to the foundation walls. h. All laundry, bathroom, and kitchen floors shall be constructed and maintained so as to be impervious to water. i. All flooring and floor coverings, including carpeting, shall be free of visible deterioration or unsanitary conditions, or chronic or persistent excessive dampness or moisture. (f) Painting, and protective coatings and treatments. (1) All exterior surfaces not inherently resistant to deterioration, including but not limited to, walls, doors, door and window frames, cornices, porches, trim, balconies, decks, and fences shall be protected from the elements and decay by painting or other protective coating or treatment with sufficient frequency to prevent deterioration. All such surfaces shall be clean and free of peeling, flaking, loose or defective surfacing materials prior to painting or coating. (2) All interior structure surfaces shall be protected from decay by painting or other protective covering or treatment and maintained in good repair to prevent deterioration. Loose or peeling wall covering or paint shall be removed, and the exposed surface shall be made smooth and be in a sanitary condition. (3) Paint chips or paint dust shall not be left on interior or exterior surfaces of the dwelling or on the premises. (4) Lead abatement, renovation, repair and painting activities are enforced by the North Carolina Lead-Based Paint Hazard Program. Firms and individuals performing renovation, repair and painting that disturbs lead-based paint in housing or child occupied facilities built before 1978, shall be certified if performing these activities for compensation and must follow specific work practices to prevent the spread of lead. (g) Property maintenance. (1) Structures. a. Floors, walls, ceilings and fixtures shall be maintained in a clean and sanitary condition. b. Every dwelling unit shall be maintained so as to prevent persistent excessive dampness or moisture on interior or exterior surfaces. Building materials discolored or deteriorated by mold or mildew or conditions that may contribute to mold, shall be cleaned, dried, and repaired. (2) Open areas. a. Property shall be graded and maintained to prevent the erosion of soil and prevent the accumulation of water on the premises, within a crawlspace, or within the structure. Surface and other drainage shall not be discharged in a manner that creates a public nuisance and shall be sloped and directed in such a way as to prevent erosion of soil on adjacent properties. b. Drainage across property lines in excess or concentrated drainage shall be contained on site or directed to an approved drainage facility. Erosion of the ground in the area of discharge shall be prevented by installation of nonerosive down drains or other devices. c. The slope of cut surfaces shall be no steeper than is safe for the intended use and shall be not more than 1 unit vertical in 2 units horizontal (50 percent slope). d. Fences shall be maintained in a safe and substantial condition, be kept in good repair, and shall meet the standards of all other city/county codes including the Durham County Unified Development Code. e. All accessory structures shall be maintained in a safe and substantial condition and be kept in good repair. Accessory structures shall include, but are not limited to sheds, storage buildings and detached carports and garages. f. Yards and courts within the boundaries of the property shall be kept free of physical hazards including but not limited to an accumulation of: rubbish, trash, garbage, debris, litter, unstacked wood, tools, materials, equipment or other items in disrepair or disarray. The covering or tarping of such conditions or items does not constitute compliance with this provision. g. Every owner shall provide a site for storage of trash receptacles in a location away from the curb and located to the side or back of the dwelling structure so that trash and garbage will not scatter on the property beyond that site. Occupants shall be responsible for ensuring that all garbage and containers are placed at the site provided. h. Retaining walls or any other wall supporting systems shall not present a physical hazard and shall be structurally safe and supported properly. i. Sidewalks and driveways. All sidewalks, walkways, stairs, driveways, parking spaces and similar areas shall be kept in a proper state of repair, and maintained free from hazardous conditions. j. Premises identification. Housing (dwellings) shall have approved address identification. The address identification shall be plainly legible and placed in a position that is visible from the street or road fronting the property. Address identification shall contrast with their background. Numbers shall not be spelled out. Address numbers shall be a minimum of four inches (102 mm) high with a minimum stroke width of one-half inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other identification shall be maintained. (3) Infestation. a. Grounds and structures shall be maintained free of insect vermin, and rodent harborage and infestation. Structures in which insects, vermin, rodents, or their harborage are found shall be promptly exterminated by generally accepted method of extermination that will not be injurious to human health. After elimination of infestations, proper precautions shall be taken to prevent reinfestation. The owner of any structure shall be responsible for elimination of any infestations within the structure prior to renting or leasing the structure. b. Every basement window used or intended to be used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or such other device as will effectively prevent their entrance. (h) Electrical standards. (1) Electrical service. a. Every dwelling unit and all public and common areas shall be supplied with adequate electric service, which shall be properly installed pursuant to the applicable portions of the North Carolina State Building Code. b. All receptacles, switches, fixtures and devices shall be in good repair and safely operable or disconnected and properly sealed off. c. Flexible cords shall not be used as a substitute for the fixed wiring; run through holes in walls, ceilings, or floors; run through doorways, windows or similar openings; attached to building surfaces; concealed behind building walls, ceilings or floors. d. Circuits shall not be overloaded. e. Fuses shall be sized correctly and not bridged out. f. Every public hall and stairway in every multifamily dwelling shall be adequately lighted at all times. Refer to subsection (d) of this section. g. All electric wiring, devices, appliances and fixtures shall be installed and maintained in accordance with the current city and state electrical codes, except as herein stated. (2) Electrical outlets. a. Every habitable room shall contain at least two separate duplex convenience outlets. Outlets shall be located as reasonable as possible to provide service to appliances in different parts of the same room. b. All outdoor outlets and electrical devices shall be ground-fault circuit interruption (GFCI) protected. (3) Electrical fixtures. At least one fixed in place ceiling or wall type electric light fixture shall be provided in every toilet room, bathroom, laundry room, furnace room, public hall, basement or any other area in which artificial light is required for the safety and welfare of the occupants. A switched wall receptacle or light fixture shall be acceptable in a bedroom, living room or den. (i) Plumbing standards. (1) Every dwelling unit shall be connected to a city water supply and sanitary sewer system unless the dwelling unit is connected to a county approved water supply and sanitary sewer system. (2) All plumbing, water closets and other plumbing fixtures in every dwelling or dwelling unit shall be installed and maintained in good working condition and repair, shall be kept free from obstructions, leaks and defects, and be capable of performing the function for which such plumbing fixtures are designed. Plumbing shall be installed and maintained in accordance with the requirements of this article and the applicable portions of the North Carolina State Residential Building Code. (3) All plumbing shall be so maintained and used as to prevent contamination of the water supply through cross connections or back siphoning. (4) All fixtures, piping and other plumbing system components shall be in proper working condition with no leaks. (5) The water supply system for every dwelling unit shall provide an adequate amount of running water under pressure to all fixtures simultaneously at pressures adequate to enable the fixtures to function properly, safely, and free from defects and leaks. (6) No fixtures shall be cracked, broken or badly chipped. (7) All water piping shall be protected from freezing by proper installation in enclosed or concealed areas or by such other means as approved by a city plumbing inspector. (8) At least one three-inch minimum size main plumbing vent shall be properly installed for each building. (9) Soil and water lines shall be properly supported with no broken or leaking lines. (10) Bathroom. Every dwelling unit shall contain, within a room which affords privacy, a toilet, lavatory basin and either a tub or shower in good working condition which shall be properly connected to the public sanitary sewer or to an approved sewage disposal system. All lavatory basins, bathtubs, and showers shall be properly connected to both hot and cold water lines, and the toilet shall be properly connected to a cold water line. (11) Access to all bathrooms shall be through a weather tight and heated area. (12) Bathroom walls and floors. Cleanable nonabsorbent water-resistant material on bathroom wall surfaces shall extend at least 48 inches above a bathtub and 72 inches above the floor of a shower stall. Such materials on walls shall form a watertight joint with the bathtub or shower. The floor of bathrooms shall be made impervious to water to prevent structural deterioration and any development of unsanitary conditions. (13) Water heating unit. Every dwelling or dwelling unit shall have supplied a water heating unit which has been listed by a testing agency and is properly installed, operated, and maintained in safe and good working condition and is properly connected to the bathtub or shower, sink and lavatory basin, as required in this article. Such water heating unit shall be capable of automatically heating water to a temperature of 120 degrees Fahrenheit and capable of meeting normal demands at every required outlet, even though the dwelling's heating unit is not in operation. All gas-fired water heaters shall be vented to the outside. (j) Fire and safety standards. (1) Fireproofing and fire protection. Every building used in whole or in part for dwelling purposes shall be provided with the fireproofing required by laws and ordinances of the city. Such fireproofing shall include, but not be limited to, the separation between occupancies, the enclosure of furnace rooms and the enclosure of stairwells, where applicable. All required fireproofing shall be maintained in a good state of repair. All fire doors shall be maintained in openable condition and shall be equipped with approved self-closing devices. (2) Fire extinguishing equipment. All fire extinguishing equipment required by the laws, ordinances and regulations of the city shall be provided and maintained in an operable condition. (3) Smoke detectors. All dwellings and dwelling units shall be equipped with a smoke detector (battery operated or 110 volt) which has been listed by a testing agency (such as Underwriters Laboratories) and such detector shall be installed in each sleeping room and outside of each sleeping area inside the dwelling unit. All smoke detectors shall be located on or near the ceiling of the room wherein it is located and shall be installed in accordance with the manufacturer's instructions and maintained in proper working condition. When a dwelling unit is subject to a rental agreement, the landlord and/or tenant shall be responsible for placement of batteries in the smoke detector as provided in G.S. 42-42(a)(5). (4) Fire alarm systems. All fire alarm systems required by the laws, ordinances and regulations of the city shall be provided and maintained in an operable condition. (5) Flammable liquids. The use of gasoline stoves or other similar fuel-burning appliances using highly flammable liquids and the use of portable kerosene stoves or other similar fuel-burning portable appliances for cooking is prohibited. The occupant of any dwelling or dwelling unit shall not have or store flammable liquids or gas or any combustible material in a quantity greater than that permitted by the city's fire prevention code. (6) Abandoned iceboxes. The doors shall be removed from all iceboxes, refrigerators and other large air-tight containers which are abandoned, and which are accessible to children, unless the door or lock can be released or opened from the inside. (7) Lead remediation. When notified by the county health department of the existence of a lead hazard stemming from a component associated with the structure of the dwelling unit which is affecting children less than six years old, the administrator shall initiate action requiring the owner to remediate the hazard by approved methods, within a time specified by the administrator, or to vacate and close the dwelling. The failure of an owner to remediate the hazard as directed by the administrator may result in the condemning and demolishing of the dwelling. (8) Carbon monoxide alarms. A minimum of one operable carbon monoxide alarm per habitable level shall be provided in all dwelling units having a fossil-fuel burning heater, appliance, or fireplace, and in any dwelling unit having an attached garage.

(Ord. No. 16682, § 1(Exh. A), 6-15-2026)

Ask a question about Durham law

Corpus searches the Durham sections it holds and shows the ones that match, with their citations. Free, no sign-in.