Sec. 44-1170. - Standards for developments in the floodway.

(a) General. (1) Any development in the floodway shall comply with Division 4 of this article and have a low flood damage potential. (2) Applicants shall provide an analysis calculating the effects of this proposal on the regional flood height to determine the effects of the proposal according to Sections 44-1134 and 44-1279(c). The analysis must be completed by a registered professional engineer in the State of Wisconsin. (3) Any encroachment on the regulatory floodway is prohibited unless the data submitted pursuant to subsection (2) above demonstrates that the encroachment will cause no increase in flood elevations in flood events up to the base flood at any location or removes the encroached area from the regulatory floodway as provided in Section 44-1106. (b) Structures. (1) Structures accessory to permanent open space uses, including utility and sanitary facilities, or which are functionally dependent on a waterfront location may be allowed by permit if the structures comply with the following criteria. a. Such structure is not designed for human habitation, does not have a high flood damage potential, and is constructed to minimize flood damage. b. Either the lowest floor of the structure is elevated to or above the flood protection elevation or the structure otherwise meets all the following standards. 1. The lowest floor is elevated to or above the regional flood elevation and is dry floodproofed so that the structure is watertight with walls substantially impermeable to the passage of water and completely dry to the flood protection elevation without human intervention during flooding. 2. The structural components are capable of meeting all provisions of subsection (b)(3) below. 3. A registered professional engineer or architect has certified, through the use of a Federal Emergency Management Agency Floodproofing Certificate, that the design and methods of construction are in accordance with subsection (b)(3). c. The structure is anchored to resist flotation, collapse, and lateral movement. d. Mechanical and utility equipment are elevated to or above the flood protection elevation. e. The structure does not obstruct the flow of flood waters or cause any increase in flood levels during the occurrence of the regional flood. (2) In order to develop a structure designed to allow the automatic entry of floodwaters below the regional flood elevation, an applicant shall submit a plan that satisfies the requirements of this section and meets or exceeds the following standards. a. The lowest floor is elevated to or above the regional flood elevation. b. The structure has a minimum of two openings which have a total net area of not less than one square inch for every square foot of enclosed area subject to flooding. c. The bottom of all such openings shall be no higher than one foot above the lowest adjacent grade. Openings may be equipped with screens, louvers, valves, or other coverings or devices, provided that they permit the automatic entry and exit of floodwaters, otherwise must remain open. d. The use must be limited to parking, building access, or limited storage. (3) Certification. Whenever floodproofing measures are required, a registered professional engineer or architect shall certify that the following floodproofing measures will be utilized, where appropriate, and are adequate to withstand the flood depths, pressures, velocities, impact and uplift forces, and other factors associated with the regional flood. a. Reinforcement of floors and walls to resist rupture, collapse, or lateral movement caused by water pressures or debris buildup. b. Construction of wells, water supply systems, and waste treatment systems so as to prevent the entrance of flood waters in such systems. Said systems must comply with this Division, including the provisions of Sections 44-1171(4) and (5). c. Subsurface drainage systems to relieve external pressures on foundation walls and basement floors. d. Cutoff valves on sewer lines or the elimination of gravity flow basement drains. e. Placement of utilities at or above the flood protection elevation. (c) Public utilities, streets, and bridges. Public utilities, streets, and bridges may be allowed by permit if the following criteria are met. (1) Adequate floodproofing measures are provided to the flood protection elevation. (2) Construction meets the development standards of Section 44-1134. (d) Fills or deposition of materials. Fills or deposition of materials may be allowed by permit if the following criteria are met. (1) The requirements of Section 44-1134 are satisfied. (2) No material is deposited in navigable waters unless a permit is issued by the Department pursuant to Wis. Stats. Ch. 30 and, if applicable, the federal government issues a permit pursuant to Section 404 of the Federal Water Pollution Control Act, Amendments of 1972, 33 U.S.C. 1344, and all other requirements have been met. (3) The fill or other materials will be protected against erosion by riprap, vegetative cover, sheet piling, or bulkheading. (4) The fill is not classified as a solid or hazardous material.

(Ord. No. 05-23, § 1, 3-21-2023)

Ask a question about Green Bay law

Corpus searches the Green Bay sections it holds and shows the ones that match, with their citations. Free, no sign-in.