§ 14.04.155 — Section 2304.10.2 of the 2025 Edition of the California Building Code is amended to read as follows, Table 2304.10.2 is adopted as published
Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.155
Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/adfb3552-431e-4b8e-892e-92b6de7c551e
14.04.155 - Section 2304.10.2 of the 2025 Edition of the California Building Code is amended to read as follows, Table 2304.10.2 is adopted as published.
2304.10.2 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.2. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F. Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.
(Ord. No. 7461, § 5, 11-10-2025)
Ask a question about Pasadena law
Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.
