Sec. 7-192. - Deletions, modifications and amendments.
The International Residential Code, 2018 edition, Chapters 1—10; 44 and appendixes "E", "H," and "J," as adopted in this division, are deleted, modified and amended with state law references, if any, as follows:
(1) Subsection [EB] R102.7 entitled "Existing Structures" shall be amended to read as follows:
"The legal occupancy of any structure existing on the date of adoption of this Code shall be permitted to continue without change, except as is specifically covered in this Code or as is deemed necessary by the Building Official for the general safety and welfare of the occupants and the public."
(2) Delete Subsection R104.10.1 "Flood hazard areas" in its entirety.
(3) Reserved.
(4) Delete Subsection R105.2 "Work exempt from Permit" in its entirety.
(5) Delete Subsection R105.2.2 "Repairs" in its entirety.
(6) Delete Subsection R105.2.3 "Public service agencies" in its entirety.
(7) Delete Subsection R105.3.1.1 "Determination of substantially improved or substantially damaged existing buildings in flood hazard areas." in its entirety.
(8) Delete Subsection R106.1.4 "Information for construction in flood hazard areas" in its entirety.
(9) Amend Subsection R108.3 "Building permit valuations" to read as follows:
Building permit valuation shall include total value of the work for which a permit is being issued, such as electrical, gas, mechanical, plumbing equipment and other permanent systems, including materials and labor.
Building permits for the construction of, alterations to, repairs to, and/or additions to, buildings or other residential structures governed by this code shall be assessed in the following manner:
(a) For alterations to, repairs to, and/or additions to, buildings or to other residential structures governed by this code, the permit fee shall be the greater of $25.00 or the amount of the total contract price multiplied by .0055 of the full estimated cost of work for each building or structure; however, this section shall not apply to the repair of any building whenever the reasonable cost of the material and labor for such repair is not in excess of $250.00 and no structural work is involved.
(b) Valuation for new construction of residential one- and two- family dwellings the building permit fees shall be based on multiplying the heated area square footage by $15.00, the unheated areas and unheated basement area square footage by $7.50 and adding the results. The permit fee will be calculated on the value of the sum of the total valuation from above multiplied by .0055.
(c) Valuation for new townhomes/single family attached dwellings governed by this code, the permit fee shall be the greater of $25.00 or the amount of the total contract price multiplied by .0055 of the full estimated cost of work for each townhome/single family attached dwelling.
(d) For the moving of any building or structure, the fee shall be $25.00.
(e) For the demolition of Residential 1 and 2 family dwellings, the fee shall be $25.00.
(f) For the setup or installation of a manufactured home/mobile home the permit fee shall be $15.00.
(g) For retaining walls constructed of any material and retaining more than four feet of earth above the footing, the permit fee shall be greater of $25.00 or the amount of the contract amount of the wall construction multiplied by .0055.
If for any reason an installation does not pass inspection, an additional inspection shall be made after the installation has been changed so as to conform to the requirements set forth in the article. A re-inspection fee may be charged at the rate as follows: 1 st re-inspection $25.00, 2 nd re-inspection $50.00, 3 rd re-inspection $75.00, 4 or more re-inspections $100.00.
(10) Subsection R109.1.2 "Plumbing, mechanical, gas, and electrical systems inspection" shall be amended to read:
"Rough inspection of plumbing, mechanical, gas and electrical systems, including low voltage wiring, shall be made prior to covering or concealment, before fixtures or appliances are set or installed, and prior to framing inspection."
(11) Subsection R109.1.3 "Floodplain inspections" shall be deleted in its entirety.
(12) Add Subsection R109.1.5.2 "Temporary power inspection"-Construction of new one-and-two family residential structures will require 30-day temporary power prior to the final inspection, in order to verify equipment safety and operation for all electrical, mechanical, gas and plumbing systems. The permit holder of record will schedule the inspection. Deficiencies noted in all equipment and systems shall be corrected and scheduled by the permit holder for re-inspection prior to final inspection. Upon re-inspection, if noted deficiencies have not been corrected, the Building Official shall be authorized to assess additional fees as necessary to be paid by the permit holder of record.
(13) Section R110 "Certificate of Occupancy" shall be amended to read as follows:
a. Amend subsection R110.1 "Use and occupancy" to read:
"No building or structure shall be used or occupied, and no change in the existing occupancy classification of a building or structure or portion thereof shall be made until the building official has issued a certificate of occupancy or letter of completion therefore as provided herein. Issuance of a certificate of occupancy or letter of completion shall not be construed as an approval of a violation of the provisions of this code or of other ordinances of the jurisdiction. Certificates presuming to give authority to violate or cancel the provisions of this code or other ordinances of the jurisdiction shall not be valid.
Exception: Certificates of occupancy are not required for work exempt from permits."
b. Amend subsection [EB] R110.2 "Change in use" to read:
"Changes in the character or use of an existing structure shall not be made except as specified in the 2018 International Existing Building Code."
c. Amend subsection R110.3 "Certificate of Letter of Completion issued" to read:
"After the building official inspects the building or structure and finds no violations of the provisions of this code or other laws that are enforced by the Inspection Department, the building official shall issue a certificate of occupancy or letter of completion which shall contain the following:
1. The building permit number.
2. The address of the structure.
3. The name and address of the owner.
4. A description of that portion of the structure for which the certificate is issued.
5. A statement that the described portion of the structure has been inspected for compliance with the requirements of this code.
6. The name of the building official.
7. Any special stipulations and conditions of the building permit."
d. Subsection R110.4 "Temporary Occupancy" shall be deleted in its entirety.
e. Amend subsection R110.5 "Revocation" to read:
"The building official shall, in writing, suspend or revoke a certificate of occupancy issued under the provisions of this code wherever the certificate is issued in error, or on the basis of incorrect information supplied, or where it is determined that the building or structure or portion thereof is in violation of any ordinance or regulation or any of the provisions of this code."
(14) Section R112 "Board of Appeals" shall be deleted in its entirety.
(15) Amend subsection 201.3 "Terms defined in other codes" to read:
"Where terms are not defined in this code such terms shall have the meanings ascribed in other codes publications of the International Code Council and as defined per NFPA 70".
(16) Amend Section R202 "Definitions" The following definitions to read as:
"(RB) ACCESSORY STRUCTURE. As defined in the definition of the City of Huntsville Appendix A- Zoning Ordinance, Article 3.—Definitions, 3.1.—Interpretation. Accessory structure. A supplementary structure detached from a principal building on the same lot and customarily incidental and subordinate to the principal building or use, containing no plumbing facilities other than one laundry sink and/or one toilet, and meeting the requirements of section 73.8 with the exception that plumbing facilities may be allowed in an accessory structure that is used as a bathhouse in conjunction with a swimming pool, provided such bathhouse does not exceed 180 square feet in area."
(RE) READY ACCESS (TO). Signifies access without the necessity for removing a panel or similar obstruction. "Attic or roof furnaces shall not be installed in any location inaccessible for inspection or repair. The space in which any attic furnace is installed shall be accessible by an opening and passageway as large as the largest part of the furnace, but not less than 22 inches by 36 inches and shall be continuous from opening to the furnace location. Every passageway in the attic shall have a solid continuous flooring 24 inches wide from the entrance opening to the furnace. A permanent light shall be provided in the passageway and appliance area. A ladder, pull down, disappearing type, or permanent stairway fastened to the building shall be provided leading to the attic opening or roof. All exterior ladders shall be metal. The requirements for a ladder, pull down disappearing type, or permanent stairway fastened to the building may be waived for the replacement of units installed before January 1986, in one - and two- family dwellings, provided a means of providing access to the units for inspection are met."
"(RB) Townhouse/Townhome and single family attached dwelling. A single-family dwelling unit constructed in a group of three or more attached units in which each unit extends from foundation to roof and with a yard or public way on not less than two sides. Per the City of Huntsville Zoning Ordinance Appendix A- Article 13, each single family attached dwelling shall be constructed on its own lot. Structures which are constructed by design as a single-family dwelling unit as noted in this definition, in which each individually single-family dwelling unit doesn't reside on its own fee simple lot shall be consider an apartment type R-2 occupancy and must follow the International Building Code.
(17) Amend Table R301.2(1) "CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA" to read as:
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA (excerpt)
Roof Snow Load footnote o | Wind Design Speed footnote d | Seismic Design Category footnote f | Subject to Damage From | | | Winter Design Temp footnote e | Ice Barrier Underlayment Required footnote h | Flood Hazards footnote g | Air Freezing Index footnote i | Mean Annual Temp footnote j
Roof Snow Load footnote o | Wind Design Speed footnote d | Seismic Design Category footnote f | Weathering footnote a | Frost Line Depth footnote b | Termite footnote c | Winter Design Temp footnote e | Ice Barrier Underlayment Required footnote h | Flood Hazards footnote g | Air Freezing Index footnote i | Mean Annual Temp footnote j
10 | 90 mph | B | Moderate | 12 inches | Very | 16 | NO | COH Local Adoption | Under 200 | 59.4
For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s.
a. Where weathering requires a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code, the frost line depth strength required for weathering shall govern.
The weathering column shall be filled in with the weathering index, "negligible," "moderate" or "severe" for concrete as determined from Figure R301.2(4). The grade of masonry units shall be determined from ASTM C34, C55, C62, C73, C90, C129, C145, C216 or C652.
b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), the frost line depth strength required for weathering shall govern. The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade.
c. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage.
d. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(5)A]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4.
e. The outdoor design dry-bulb temperature shall be selected from the columns of 971/2-percent values for winter from Appendix D of the International Plumbing Code. Deviations from the Appendix D temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. [Also see Figure R301.2(1).]
f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1.
g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel numbers and dates of the currently effective FIRMs and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended.
h. In accordance with Sections R905.1.2, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO."
i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99 percent) value on the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)."
j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index-USA Method (Base 32°F)."
k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
l. In accordance with Figure R301.2(5)A, where there is local historical data documenting unusual wind conditions, the jurisdiction shall fill in this part of the table with "YES" and identify any specific requirements. Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
m. In accordance with Section R301.2.1.2 the jurisdiction shall indicate the wind-borne debris wind zone(s). Otherwise, the jurisdiction shall indicate "NO" in this part of the table.
n. The jurisdiction shall fill in these sections of the table to establish the design criteria using Table 1a or 1b from ACCA Manual J or established criteria determined by the jurisdiction.
o. The jurisdiction shall fill in this section of the table using the Ground Snow Loads in Figure R301.2(6).
(18) Delete Section R301.2.4 "Floodplain Construction" in its entirety.
(19) Amend Subsection R302.1 "Exterior Walls" to read:
Construction, projections, openings and penetrations of exterior walls of dwellings and accessory buildings shall comply with Table R302.1 (1); or dwellings equipped throughout with an automatic sprinkler system shall compline with Table R302.1 (2).
Exceptions.
1. Walls, projections, openings or penetrations in walls perpendicular to the line used to determine the fire separation distance.
2. Walls of individual dwellings and their accessory structures located on the same lot.
3. Foundation vents installed in compliance with this code are permitted.
(20) Amend subsection R302.2.2 "Common Wall" to read.
Common walls separating townhouses shall be separated by a 2-hour fire-resistance-rated wall assemblies tested in accordance with ASTM E119, UL 263 or Section 703.3 of the International Building Code. The common wall shared by two townhouses shall be constructed without plumbing or mechanical equipment, ducts or vents in the cavity of the common wall. The wall shall be rated for fire exposure from both sides and shall extend to and be tight against exterior walls and the underside of the roof sheathing. Electrical installations shall be in accordance with NFPA 70. Penetrations of the membrane of common walls for electrical outlet boxes shall be in accordance with Section R302.4.
Exception:
Where a fire sprinkler system in accordance per NFPA 13D is provided, the common wall shall not be less than a 1-hour fire-resistance-rated wall assembly tested in accordance with ASTM E 119, UL263 or Section 703.3 of the International Building Code.
(21) R302.3 Two-family dwellings. Amend to read "Dwelling units in two-family dwellings shall be separated from each other by a wall and floor/ceiling assemblies having not less than a 1-hour fire-resistance rating where tested in accordance with ASTM E 119 or UL 263 or Section 703.3 of the 2018 International Building Code." Fire resistance-rated floor/ceiling and wall assemblies shall extend to and be tight against the exterior wall, and wall assemblies shall extend from the foundation to the underside of the roof sheathing.
Exception: Where a fire sprinkler system in accordance per NFPA 13D is provided, the wall shall not be less than a 1/2-hour fire-resistance-rated wall assembly tested in accordance with ASTM E 119, UL263 or Section 703.3 of the International Building Code.
(22) R302.13 Fire protection of floors.
Floor assemblies that are not required elsewhere in this code to be fire-resistance rated, shall be provided with a 1/2-inch (12.7 mm) gypsum wallboard membrane, 5/8-inch (16 mm) wood structural panel membrane, or equivalent on the underside of the floor framing member. Penetrations or openings for ducts, vents, electrical outlets, lighting, devices, luminaires, wires, speakers, drainage, piping and similar openings or penetrations shall be permitted.
Exceptions:
1. Floor assemblies located directly over a space protected by an automatic sprinkler system in accordance with NFPA 13D, or other approved equivalent sprinkler system.
2. Floor assemblies located directly over a crawl space not intended for storage or for the installation of fuel-fired or electric-powered heating appliances.
3. Portions of floor assemblies shall be permitted to be unprotected where complying with the following:
3.1. The aggregate area of the unprotected portions does not exceed 80 square feet (7.4 m2) per story.
3.2. Fireblocking in accordance with Section R302.11.1 is installed along the perimeter of the unprotected portion to separate the unprotected portion from the remainder of the floor assembly.
4. Wood floor assemblies using dimension lumber or structural composite lumber equal to or greater than 2-inch by 10-inch (50.8 mm by 254 mm) nominal dimension, or other approved floor assemblies demonstrating equivalent fire performance.
(23) R302.14 Combustible insulation clearance. Amend to read
Combustible insulation shall be separated not less than 3 inches (76 mm) from recessed luminaires, fan motors and other heat-producing devices.
Exception: Where heat-producing devices are listed for lesser clearances, combustible insulation complying with the listing requirements shall be separated in accordance with the conditions stipulated in the listing.
"Recessed luminaries installed in the building thermal envelope shall meet the requirements of current State of Alabama Adopted Residential Energy Code."
(24) R303.1 Habitable rooms. Amend Exception #1 to read "The glazed areas need not be openable where the opening is not required by Section R310 and a whole-house mechanical ventilation system is installed in accordance with the 2018 International Mechanical Code."
(25) R303.3 Bathrooms. Amend Exception to read: "The glazed areas shall not be required where artificial light and a local exhaust system are provided. The minimum local exhaust rates shall be determined in accordance with the 2018 International Mechanical Code. Exhaust air from the space shall be exhausted directly to the outdoors."
(26) R303.4. Mechanical Ventilation. Amend to read, "Where the air infiltration rate of a dwelling unit is 5 air changes per hour or less where tested with a blower door at a pressure of 0.2 inch w.c (50 Pa) in accordance with the current State of Alabama Adopted Residential Energy Code, the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with the 2018 International Mechanical Code".
(27) R303.5.1 Intake openings. Exception #2 & #3 Amended to read,
2. "Vents and chimneys serving fuel-burning appliances shall be terminated in accordance with the applicable provisions 2018 International Mechanical Code."
3. "Clothes dryer exhaust ducts shall be terminated in accordance with 2018 International Mechanical Code."
(28) R307.1 Space required. Amend to read:
"Fixtures shall be spaced in accordance with Figure R307.1, and in accordance with the requirements of the 2018 International Plumbing Code
(29) Delete Subsection R309.3 "Flood Hazard Areas" in its entirety.
(30) R309.5 Fire Sprinklers. Amend to read, "Private garages shall be protected by fire sprinklers where the garage wall has been designed based on Table R302.1(2), Footnote a. Sprinklers in garages shall be connected to an automatic sprinkler system that complies with the 2018 International Plumbing Code. Garage sprinklers shall be residential sprinklers or quick-response sprinklers, designed to provide a density of 0.05 gpm/ft2. Garage doors shall not be considered obstructions with respect to sprinkler placement."
(31) Amend Section R313 "Automatic Fire Sprinkler Systems" to read:
a. R313.1 Townhomes automatic fire sprinkler systems. Amend to read:
If an automatic residential fire sprinkler system is installed in townhouses, the design must be in accordance with NFPA 13D.
b. R313.2 One- and two-family dwellings automatic fire sprinkler systems. Amend to read:
If an automatic residential fire sprinkler system is installed in One- and two-family dwellings, the design must be in accordance with NFPA 13D.
(32) Section R322 Flood-Resistant Construction. Delete in entirety.
(33) Delete Table 403.1(1), Table 403.1(2), & Table 403.1(3) "Minimum Width and Thickness for Concrete Footings for Light-Frame Construction" in its entirety.
(34) Amend Subsection R403.1.1 "Minimum Size" to read:
The minimum size for concrete footings shall be in accordance with this section:
(a) Perimeter footings: Minimum depth of concrete shall be 12 inches by 16 inches wide unless brick veneer or masonry units are to be used for the structure, then the minimum width shall be 20 inches wide. Two (2) No. 5 reinforcing bars or Three (3) No. 4 bars, continuous at three inches above footing bottom and three inches from each side shall be used in the footings. Bottom of footing shall be a minimum of two feet below finished grade.
(b) Interior footings: Minimum size of concrete footing shall be 12 inches deep by 16 inches wide for required length unless masonry units are to be used, then the minimum width shall be 20 inches wide. Two (2) No. 5 reinforcing bars or Three (3) No. 4 bars, continuous at three inches above footing bottom and three inches from each side shall be used in the footing.
(c) Where slab and turned down footing construction is used, these minimum requirements shall not be applicable.
(d) Minimum pier footing size shall be 20 inches square by 12 inches of depth. No minimum depth of bottom of footing below finished grade is specified."
Exception: Footing designs accompanied by a geotechnical study conducted from an Alabama Licensed Engineer.
(35) Amend Subsection R403.1.7 "Footings on or adjacent to slopes" to read:
"On all building sites in the slope development district and other sites with identifiable or suspected potentially unstable subsurface soil conditions, the building applications for permitting shall be accompanied by a geotechnical study conducted by and bearing the expertise in the science of soil mechanics.
The test and analysis requirements shall be as set forth in the slope development study, section VIII, subsection C, paragraph 4 as follows:
A. Geotechnical studies: field and laboratory.
1) Field studies:
a) Residential lots: borings as required per design geotechnical study.
b) Acceptable subsurface exploration methods: test pit excavations; soil test borings; mechanical or electrical cone borings.
c) Rock coring, if required: Minimum of five feet of rock coring per boring.
d) Soil and rock classification according to (ASTM) procedures.
2) Minimum soil properties tests (natural or fill soils):
a) Shear strength (as required for analysis).
b) Standard classification tests (ASTM).
c) Consolidation tests (as required).
d) Shrink/swell potential (if applicable).
3) Groundwater data: Each boring shall be measured for groundwater.
4) Analyze slope stability and structure performance:
a) Stability analyses should be performed on the best, worst, and average soil and embankment conditions:
1) Sliding wedge and slip circle analyses should be performed on the uphill side of any cut embankment.
2) Slip circle analyses should be performed on all fill embankments.
b) Based on the analyses, the lowest safety factors should be reported for each method along with all of the design conditions.
c) Structure performance should be analyzed with respect to bearing capacity and settlement.
The application shall contain a design footing and foundation meeting the requirements set forth in the adopted slope development study, section VIII, subsection C, paragraph 5 as follows:
5) Recommended design standards:
a) Safety factors for stability: Minimum safety factor of 1.5 with adequate data, including triaxial shear tests, multiple analyses (sliding wedge infinite slope and slip circle analyses) and confident groundwater (piezometer) measurements and control.
b) Where soil and rock data indicated a large variation in strength, analyses should be reported for the worst conditions encountered. Safety factor for bearing capacity: Minimum safety factor of 3.0.
c) Allowable settlement: Maximum settlement between column footings shall not exceed the angular distortion ration D/L (D-deflection inches, L - length between columns inches) as follows: Limiting Settlement
High continuous brick walls | .0005—0.001
One-story brick buildings | .001
Reinforced concrete frame | .0025
Reinforced concrete curtain wall | .003
Steel Frame, continuous | .002
Steel Frame, simple | .005
d) Expansive soils: 2018 International Residential Code Subsection R403.1.8 sets requirements and Section 1808.6 of the 2018 International Building Code.
This design must be performed by, and bear the seal of, an engineer or architect registered in the state.
The engineer or architect shall inspect and certify that, to the best of his knowledge, the construction of the footing and foundation has been accomplished according to the required design. The certification must be on record before a certification of occupancy can be issued."
(36) Delete subsections R403.1.7.1—R403.1.7.4 in its entirety.
(37) Amend Subsection R404.1.1 "Design required" to read: (adding #3 condition)
Concrete or masonry foundation walls shall be designed in accordance with accepted engineering practice where either of the following conditions exists:
1. Walls are subject to hydrostatic pressure from ground water.
2. Walls supporting more than 48 inches (1219 mm) of unbalanced backfill that do not have permanent lateral support at the top or bottom.
3. All freestanding or cantilevered retaining walls constructed of any material and retaining more than four feet of earth above the footing shall be designed and the drawings sealed by an engineer or architect registered in the state.
(38) Amend Section R405.1. "Concrete or masonry foundations" to read:
Drains shall be provided around concrete or masonry foundations that retain habitable space below grade. Drainage tiles, gravel or crushed stone drains, perforated pipe or other approved systems or materials shall be installed at or below the top of the footing or below the bottom of the slab and shall discharge by gravity or mechanical means into an approved drainage system. Gravel or crushed stone drains shall extend not less than 1 foot (305 mm) beyond the outside edge of the footing and 6 inches (152 mm) above the top of the footing and be covered with an approved filter membrane material. The top of open joints of drain tiles shall be protected with strips of building paper. Except where otherwise recommended by the drain manufacturer, perforated drains shall be surrounded with an approved filter membrane or the filter membrane shall cover the washed gravel or crushed rock covering the drain. Drainage tiles or perforated pipe shall be placed on not less than 2 inches (51 mm) of washed gravel or crushed rock not less than one sieve size larger than the tile joint opening or perforation and covered with not less than 6 inches (152 mm) of the same material.
For crawl spaces that retain earth the grading shall be done around every foundation in such manner that storm water shall drain away from the building. The crawl space underneath the ground floor must be so graded as to drain to a point at the exterior foundation wall where a drainpipe must be provided through the foundation wall leading from the building to a point of discharge, so that the crawl space under the building will be adequately drained at all times. The grade of the crawl space and the grade of the drainpipe must be established at an elevation that is sufficient enough to prevent storm water from backing up under the building from the point of discharge. The drainpipe shall be a minimum of four inches in diameter and graded with a slope not less than one-eighth inch per foot towards the point of discharge.
(39) Delete subsection R408.7 "Flood resistance" in its entirety.
(40) Amend Subsection R506.2.3 "Vapor Retarder" to read:
"A 6-mil polyethylene or approved vapor retarder with joints lapped not less than 6 inches shall be placed between the concrete slab and the base course or the prepared sub-grade where no base courses exist.
Exception: The vapor retarder may be omitted:
1. From detached garages, detached accessory/utility structures without heat.
2. From driveways, walks, patios, and other flatwork not likely to be enclosed and heated at a later date."
(41) Delete Subsection R602.5 "Interior nonbearing walls in its entirety.
(42) Amend Subsection R1003.11.3 "Gas Appliances" to read:
"Flue lining systems for gas appliances shall be in accordance with the 2018 International Mechanical Code."
(43) Amend Subsection R1003.14 "Flue Area (Appliance)" to read:
"Chimney flues shall not be smaller in area than that of the area of the connector from the appliance [See Table R1003.14(1) and R1001.11(2)]. The sizing of a chimney flue to which multiple-appliance venting systems are connected shall be in accordance with the 2018 International Mechanical Code."
(44) Amend Appendix H Subsection AH105.2 Footings to read: Footings shall be designed as required per the amended subsection R403.1.1 "Minimum Size".
(45) Delete Appendix J Subsection AJ102.4.1 "Energy efficiency" to read "Replacement windows shall comply with current state Energy Code adopted by the Alabama Energy and Residential Code Board"
(46) Delete Appendix J Subsection AJ102.4.4 "Window control devices" in its entirety.
(47) Delete Appendix J Subsection AJ102.5 "Flood Hazard Areas" in its entirety.
(48) Amend Appendix J Subsection AJ301.2 "Water Closets" to read:
"When any water closet is replaced with a newly manufactured water closet, the replacement water closet shall comply with the requirements of the 2018 International Plumbing Code."
(49) Delete Appendix J Subsection AJ301.3 "Electrical" in its entirety.
(50) Amend Appendix J Subsection AJ501.1 "Newly Constructed Elements" to read:
"All newly constructed elements, components, and systems shall comply with the requirements of this code.
Exceptions: Operable windows may be added without requiring compliance with the light and ventilation requirements of Section R303."
(Ord. No. 21-1006, § 2, 11-18-2021, eff. 1-1-2022)