Class I magazines.
Round Rock Code of Ordinances § 16-150
in effectSec. 16-150. - Class I magazines.
(a) Structure. A magazine may be a building or excavation, tunnel or igloo, or military-type magazine or a portable magazine constructed as required in this section.
(b) Magazines to be resistant. Class I magazines shall be bullet resistant, fire resistant, weatherproof, theft resistant and well ventilated.
Exception: Magazines used for the storage of blasting agents, Class B and Class C explosives need not be bullet resistant.
(c) Building-type magazines. Building-type magazines shall be constructed of masonry, wood, metal or a combination of these materials when bullet resistance is required:
(1) Masonry units not less than eight inches in thickness with all hollow spaces filled with concrete, well-tamped sand, or equivalent material;
(2) Reinforced concrete not less than six inches in thickness;
(3) Steel walls of minimum manufacturers standard gauge No. 14 (0.0747 inch) may be used, provided there are two layers spaced at least six inches apart with all hollow spaces filled with concrete, well tamped sand or equivalent material;
(4) One layer of manufacturers standard gauge No. 6 (0.1943 inch) or heavier steel, lined on the interior with a minimum of four inches of wood;
(5) Two layers of manufacturers standard gauge No. 6 (0.1943 inch) or heavier steel, spaced a minimum one-half inch apart and lined on the interior with a minimum of two inches of wood; or
(6) Two layers of wood, at least two inches nominal thickness each, spaced a minimum of four inches apart with the hollow spaces filled with concrete, well-tamped sand, or equivalent material.
The roof shall also be protected when the magazine is located where it is possible to fire a bullet directly through it into the explosives stored inside.
NOTE: Any sheeting used shall be tongue and groove lumber or plywood.
(d) Doors. Doors shall be of bullet resistant construction and shall be installed in such a manner that the hinges and hasps cannot be removed when the doors are locked and closed. Doors shall be equipped with substantial and approved means of locking. Each door shall be equipped with two separate locks or a lock requiring two separate keys. All padlocks shall be protected with steel caps constructed so as to prevent sawing or lever action on the locks or hasps.
(e) Floors. Floors of magazines shall be securely fastened in place and shall be capable of withstanding the loads imposed.
(f) Roofs and exterior sides. The roofs and exterior sides of building-type magazines may be of wood construction covered with not less than No. 26 gauge metal. Roofs of building-type magazines located where it is possible to fire a bullet directly through the roof into the magazine at such an angle that the bullet would strike the explosives therein, shall be constructed according to subsection (c) of this section, or equipped with a sand tray located at the eaves line and covering the entire magazine ceiling area except that necessary for ventilation. Sand in the sand tray shall be maintained at a depth of not less than four inches.
(g) Ventilation. Magazines shall be ventilated to minimize dampness and heating of stored explosives. Ventilation openings shall be screened with 14 mesh, No. 21 gauge wire to prevent the entrance of sparks and shall be protected in a manner that will maintain the bullet resistance of the magazine.
(h) Interiors. Magazine interiors shall have a smooth finish with all nails, screws, bolts, and nuts countersunk or blinded.
(i) Approaches to magazines. The approaches to magazines shall be provided with warning signs reading, "EXPLOSIVES—KEEP OUT" in red letters not less than four inches in height and a stroke of at least five-eighths inch. The lettering shall be imposed upon a white background. Location of signs shall be within 100 feet of the magazine and so placed that a bullet through the sign will not strike the magazine.
(j) Warning sign on door. There shall be posted an additional warning sign on the door with the letters not less than two inches in height and a stroke of one-fourth inch on a contrasting background reading "EXPLOSIVES, DANGEROUS."
(Code 1995, § 5.211)
Source: City of Round Rock, Texas, Code of Ordinances (Municode Library, library.municode.com)URL: https://library.municode.com/tx/round_rock/codes/code_of_ordinances?nodeId=PTIICOOR_CH16FIPRPR_ARTVIEX_S16-150CLIMAFetched: 11/16/2026