Sec. 49-1734. - Sanitary and storm sewer pipe installation.
(a) Bedding. (1) The trench bottom shall provide a firm, stable and uniform support for the full length of the pipe. Any part of the trench bottom that is over-excavated shall be backfilled to grade and compacted as required to provide firm pipe support. Blocking shall not be used to bring the pipe to grade. (2) If wet conditions exist, the mud must be removed and replaced with a compacted bedding material four inches to six inches deep. (No compaction is required if Class IA or IB material is used.) (3) If the pipe is 24 inches in diameter or more and ground water is infiltrating the trench, the bottom of the trench must be over-excavated 12 inches and replaced with 12 inches of Class IA material. If the pipe diameter is less than 24 inches then eight inches of Class IA material and four inches of Class IB are required. (No compaction is required if Class IA or IB material is used. IA is defined as angular, crushed stone or rock one and one-half inches and larger and contains little or no fines. IB is defined as angular crushed stone or rock three-eighth inch to one and one-half inches, what is generally known as three-quarter crush and run.) (b) Haunching. (1) The haunch area is from the bottom of the trench to the springline of the pipe. The material used in the haunching area is the most important factor affecting pipe deflection. (2) For four-inch and six-inch pipe sizes, native soil may be used in the haunching area (excluding frozen or clumped dirt). It must be compacted by use of a hand tamper. (3) For pipe sizes eight inches in diameter but not larger than 24 inches in diameter, a Class IB material may be used with no compaction required. For sizes larger than 24 inches in diameter, a Class IA or IB material may be used with no compaction required. (4) For pipe sizes eight inches and larger, a Class II material may be used with a compaction of 85 percent. A test report by a third party confirming the compaction will be required. (Note: Class II is gravel or gravel-sand with little or no fines.) (5) For pipe sizes eight inches and larger, a Class III or IVA material may be used with a compaction of 90 percent. A test report by a third party confirming the compaction will be required. (Note: Class III is sand. IVA is native material.) (c) Initial backfill. Initial backfill is the portion from the springline to six inches above the crown of the pipe. The same requirements for haunching will apply but with separate compaction tests for each area. (No compaction test is required if Class IA or IB is used.) (d) Final backfill. Final backfill is that portion of the trench from six inches above the crown to the ground level. There are no special compaction requirements in this area except in the street or street right-of-way. However, the use of water to compact the trench shall be prohibited. (e) Types of pipe. These standards cover all solid wall PVC pipe, smooth interior polyethylene pipe and smooth interior corrugated PVC pipe. (f) Making repairs to city sewer. If a section of the main must be replaced with a new wye, after the section has been replaced, all mud shall be removed and only a Class IB material used a minimum of six inches under the pipe and 12 inches over the crown of the pipe. (g) Width of the trench. For solid wall PVC, there shall be a minimum of six inches on each side of the pipe for pipe sizes four inches to eight inches. For larger sizes, see the table below. For smooth interior polyethylene or PVC corrugated pipe, the installation shall comply with Table 49-1734 below. Table 49-1734 Solid Wall PVC | Smooth Interior Polyethylene or PVC Corrugated Pipe Pipe Size | Minimum Trench Width Inches | Pipe Size | Minimum Trench Width Inches 10" | 26 | 4"—8" | * 12" | 30 | 10" | 24 15" | 30 | 12" | 28 18" | 32 | 15" | 35 21" | 34 | 18" | 43 24" | 36 | 24" | 56 27" | 40 | 30" | 60 30" | 42 | 36" | 65 33" | 45 | 42" | 84 36" | 48 | 48" | 91 42" | 54 | 54" | 97 48" | 60 | 60" | 103 * A minimum of six inches on each side of the pipe Class IVB and V materials will not be allowed unless compaction requirements are designed by civil engineer licensed to practice in the State of Nebraska and compaction tests are obtained to confirm this optional system.
(Ord. No. 40524, § 1, 10-20-15; Ord. No. 42654, § 53, 8-13-21)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.