§ 10.08 — CONSTRUCTION OF DRIVEWAY APPROACHES AND PARKING FACILITIES
Madison General Ordinances (Rev. 28, Update 3: codified through ORD-26-00040, published August 3, 2026) · Madison General Ordinances § 10.08
Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/b10b7510-bc22-4312-803d-1f425f35912f
10.08 - CONSTRUCTION OF DRIVEWAY APPROACHES AND PARKING FACILITIES.
Every driveway approach leading from any street to the lot line of any lot and every lot used as a parking facility shall hereafter be constructed only in accordance with the following requirements: (1) Definitions. For the purpose of this section the following words are defined: (a) Angle of approach shall mean the least angle between the center line of the driveway approach and the pavement edge. (b) Automobile laundry shall mean a building or portion thereof containing facilities for washing automobiles using self-service methods or production line methods with a chain conveyor, blower, steam cleaning device or other mechanical devices, or any premise with a capacity of washing twenty (20) or more vehicles per eight (8) hour day. (Am. by Ord. 12,008, 1-15-98) (c) Board shall mean the Board of Public Works of the City of Madison, Wisconsin. (d) Class I driveway approach shall mean all those by which a street with a concrete curb is connected with a residence, barn, private garage or other improved property and ordinarily used only by the owner or occupant of the premises, their guests and necessary service vehicles. (Am. by ORD-14-00012, 1-14-14) (e) Class II driveway approach shall mean the same as Class I but located where the street is constructed with shoulders without concrete curbs. (f) Class III driveway approach shall mean all those by which a street with a concrete curb is connected with private or public property and which is used for commercial purposes or which will ordinarily carry a much heavier traffic movement than Classes I and II. (g) Class III(a) driveway approach shall mean all those by which a street with a concrete curb is connected with private or public property and which is used for commercial purposes, primarily used by semitrailers and buses. (h) Class IV driveway approach shall mean the same as Class III but located where the street is constructed with shoulders without concrete curbs. (i) Class V driveway approach shall mean all of those by which a street with a concrete curb is connected with public property for the exclusive use of emergency fire equipment. (j) Commercial site shall mean one tract consisting of one or more contiguous lots or parts of lots which are to be used for interdependent ingress and egress of vehicles and containing one or more off-street loading or parking facilities or any commercial or residential site having five (5) or more parking stalls. (k) Curb cut shall mean that section of concrete curb removed to permit ingress and egress from adjacent property and shall be measured between the points of tangency of the driveway approach radii with the normal street curbing. (l) Driveway shall mean every way or area in private ownership and used for vehicular travel back of the street right-of-way line. (m) Driveway approach shall mean an area improved for vehicular traffic on a public street right-of-way which connects the traveled portion of the street with a driveway. (n) Entrance shall mean the point of connection of the driveway and the driveway approach at the street right-of-way line. (o) Intersection turning area shall mean the part of the intersection included between the radius line used to connect the curb lines and the intersection of the curb lines if extended. (p) Off-street vehicle facility shall mean any area or structure behind the street right-of-way improved and/or used for the parking, movement, servicing or storage of motor vehicles. (q) Permit shall mean a permit to construct a driveway entrance and approach of a specified class granted by the City Engineering Division and Traffic Engineering Division upon application therefore in accordance with this ordinance. (r) Permittee shall mean the applicant to whom the Board grants a permit. (s) Residential site shall mean a single parcel in a residential zone containing a single residential structure of one or more dwelling units having four (4) or less parking stalls. (t) Semitrailer refers to a combination of truck-tractor pulling a single semitrailer unit. (u) Sight distance shall mean the distance from the driver's eye (driver's vehicle approaching the intersection) to the point of intersection of the paths of driver's vehicle and another approaching vehicle on a cross street, measured from the point where, as both vehicles approach the intersection, each driver is first able to see the other's vehicle. (Am. by ORD-14-00012, 1-14-14) (v) Medium and large vehicle shall mean any automobile or truck exceeding sixteen (16) feet in length. (w) Small vehicle shall mean any automobile or truck sixteen (16) feet in length or less. (2) Number of Entrances. (a) A maximum of two (2) entrances shall be permitted to a residential site provided that where a single off-street parking facility shall serve more than one residential site no more than two (2) entrances shall be permitted to such a facility. (b) A maximum of two (2) driveway entrances shall be permitted to a commercial site from each of any one (1) or two (2) abutting streets. (c) When in the opinion of the Director of Traffic Engineering, after hearing the views of the permittee, it is in the interests of good traffic operation, the Director of Traffic Engineering may permit: (Am. by ORD-23-00098, 10-26-23) 1. One (1) additional driveway entrance along a continuous site frontage in excess of six hundred (600) feet or two (2) additional driveway entrances along a continuous site frontage in excess of twelve hundred (1,200) feet. 2. One (1) additional entrance from each of not more than two (2) abutting streets where continuous frontage is less than six hundred (600) feet; provided that such additional entrances be used exclusively as a service drive for the purpose of loading or unloading materials or merchandise, and which drive is physically separated from other off-street vehicle facilities and not available to customers thereof through the use of a six-inch (6") high raised rolled asphalt or poured in place concrete curb or a guardrail erected eighteen (18) inches in height to the center measured from the paved parking surface. 3. One (1) or two (2) driveway entrances from additional abutting streets. (3) Location of Entrances. (a) No entrance shall be closer than ten (10) feet to the right-of-way line of an intersecting street provided that no part of any driveway approach shall encroach on any intersection turning area (curb radius). Alleys shall be exempt from this provision and may be defined as "approaches," provided that the total maximum dimensions shall not exceed those permitted for other "approaches" in the same class. Where the alley is not included, the entrance must be a minimum of five (5) feet from the nearest boundary line of the alley. (b) No entrance shall be closer than five (5) feet to an adjacent property line; provided, however, that in cases of practical difficulty or unnecessary hardship the City Engineer, Director of Traffic Engineering and Director of the Building Inspection Division may jointly reduce such requirement with subsequent appeal to the Board, if necessary. No driveway approach shall be so constructed that any part of the same extends in front of property belonging to a person other than the permittee unless both property owners sign a joint application for a permit. (Am. by Ord. 8081, 7-29-83; ORD-08-00109, 10-7-08; Am. by ORD-23-00098, 10-26-23) (c) Any two entrances shall be at least ten (10) feet apart and in no case less than the sum of the approach radii. (d) All entrances and approaches shall be so located as to provide adequate sight distance in both directions along the street for safe access to the street without interfering with vehicular or pedestrian traffic on the street. (e) No entrance shall be located where an existing City street tree is present unless no other location is available, the applicant obtains a tree trimming, pruning or removal permit under Sec. 10.101, and the applicant complies with Sec. 10.105. (Cr. by ORD-25-00071, 10-16-25) (4) Design Criteria. (a) Special Requirements. 1. Class I Maximum permitted width of entrance ..... 20 feet Minimum permitted width of entrance ..... 8 feet Maximum permitted width of driveway ..... 20 feet Minimum permitted width of driveway ..... 8 feet Maximum permitted curb cut ..... 30 feet Minimum permitted curb cut ..... 14 feet Maximum turning radius at pavement edge ..... 5 feet 2. Class II Maximum permitted width of entrance ..... 30 feet Minimum permitted width of entrance ..... 12 feet Maximum permitted width of driveway ..... 30 feet Minimum permitted width of driveway ..... 12 feet Maximum permitted width of approach ..... 50 feet Minimum permitted width of approach ..... 32 feet Maximum turning radius at pavement edge ..... 10 feet 3. Class III* [2] Maximum permitted width of entrance ..... 30 feet Minimum permitted width of entrance ..... 18 feet or two entrances of 10 ft. min. under one-way operation. Maximum permitted width of driveway ..... 30 feet Minimum permitted width of driveway ..... 18 feet or two driveways of 10 ft. min. under one-way operation. Maximum permitted curb cut ..... 50 feet Minimum permitted curb cut ..... 28 feet Turning radius at pavement edge—Minimum ..... 5 feet Maximum 10 ft. provided no radius greater than 5 ft. shall encroach on a sidewalk. 4. Class III(a) Maximum permitted width of entrance ..... 40 feet Minimum permitted width of entrance ..... 35 feet Maximum permitted width of driveway ..... 40 feet Minimum permitted width of driveway ..... 35 feet Maximum permitted width of curb cut ..... 60 feet Minimum permitted width of curb cut ..... 45 feet Maximum turning radius at pavement edge ..... 10 feet Minimum turning radius at pavement edge ..... 5 feet 5. Class IV* Maximum permitted width of entrance ..... 40 feet Minimum permitted width of entrance ..... 25 feet Maximum permitted width of driveway ..... 40 feet Minimum permitted width of driveway ..... 25 feet Maximum permitted width of approach ..... 70 feet Minimum permitted width of approach ..... 55 feet Maximum turning radii Between pavement edge and outside edge of approach ..... 20 feet Edge of approach (adjacent approach edges where two approaches are constructed) ..... 10 feet 6. Class V—Emergency Fire Equipment. Widths and radii for fire station driveways and approaches shall be determined by the dimensions and operating characteristics of the vehicles involved and deviations from the above design characteristics must be approved by the Board of Public Works. 7. The maximum width permitted herein for Class I and Class II driveways may be exceeded when approved by the Zoning Administrator for the express purpose of complimenting multiple off-street parking spaces. (Cr. by Ord. 10,224, 3-29-91) (b) The Director of Traffic Engineering may approve a Class III(a) driveway approach if plans are submitted by the applicant showing that the requested driveway approach will be used nearly exclusively by semitrailers and/or buses serving the site, and that other driveway approaches intended for exclusive use by smaller vehicles will not be used by semitrailers and/or buses and, further, that the use of the property is one of the following: (Am. by ORD-23-00098, 10-26-23) 1. Post offices (used as distribution centers). 2. Mobile home sales and service. 3. Weigh stations. 4. Bus stations, bus terminals, bus turnarounds, bus garages and bus lots. 5. Building material sales establishments. 6. Express and parcel delivery establishments. 7. Feed and seed stores. 8. Feed mixing and grinding plants. 9. Milk and ice cream processing and bulk terminals. 10. Bottling or distribution plants of soft drinks, milk, beer, fuel and ice. 11. Storage and warehousing establishments. 12. Wholesaling establishments. 13. Service entrances to community and regional shopping centers. 14. Machinery and equipment sales and service establishments. 15. Highway maintenance shops and yards. 16. Foundries, machine shops, iron, steel and metal fabrication establishments. 17. Brick, tile or terra-cotta manufacture. 18. Asphalt and concrete batching or ready-mix plants. 19. Cartage establishments. 20. Concrete products casting. 21. Motor freight terminals. 22. Railroad freight terminals, railroad switching and classification yards, repair shops and roundhouses. (c) The following special design features may be permitted at high volume entrances if approved by the Board after reviewing the recommendations of the Director of Traffic Engineering: (Am. by ORD-23-00098, 10-26-23) 1. One or more driveway approaches may be replaced by a street type entrance. The cost of additional drainage structures necessitated by such entrances shall be borne by the permittee. 2. One or more driveways to a major traffic generator may be replaced with special geometrically designed approaches and entrances where such generated traffic volumes and turning movements are in such quantities as to significantly reduce the capacity of the adjacent street and/or pose a hazard to through traffic on the adjacent street. These special geometrically designed approaches and entrances include (but are not limited to) speed change lanes, median crossovers, traffic islands and special driveway approach design treatments. The owner of the traffic generator shall be financially responsible for the cost of the special geometrically designed approaches and entrances as well as the cost of additional drainage structures, street lighting and traffic signals, and conduit necessitated at such approaches and entrances. (d) The angle of approach of any driveway approach shall be not less than forty-five (45) degrees. A ninety (90) degree angle of approach is preferable on Class I and Class III approaches. (e) Right-of-way areas adjacent to driveway approaches shall be left unimproved for vehicular use. The drawing accompanying the application shall show exactly how encroachment on such adjacent areas is to be prevented. If encroachment develops a need for additional protection, it shall be provided promptly by the permittee. (f) All driveway approaches shall be constructed and the right-of-way area adjacent to or between approaches shall be graded at the permittee's expense, subject to drainage requirements as specified by the Board. (g) The driveway approach between the property line and the road pavement or street curb line shall be paved in accordance with specifications for such concrete, asphalt or crushed stone work prescribed by the Board. All Class III and Class III(a) approaches shall be constructed of concrete. All Class IV driveways shall be constructed of asphalt. (h) If required by the Director of Traffic Engineering, polyvinyl chloride (PVC) conduit up to three (3) inches in diameter shall be placed twelve (12) inches back of the curb line and a minimum of twenty-four (24) inches below the flow line and extending to the intersecting point of the curb radius and the curb line under each driveway approach. This conduit shall be turned up at each end to terrace finish grade using a 90° elbow and capped at this grade with a permanent PVC cap. (See Figure I in Sec. 10.08(6)(b)1.) The Director of Traffic Engineering may require a deposit to insure installation of this conduit and any other associated structures. (Am. by Ord. 11,512, 1-26-96; Am. by ORD-23-00098, 10-26-23) (i) Gasoline pumps or similar facilities served by such driveways and approaches shall be a minimum of fifteen (15) feet from the right-of-way line of the street measured to the center of the gasoline pump and no driveway approach shall be constructed to serve any such existing facility which is less than twelve (12) feet from the right-of-way line. (5) Special Provisions for Entrances and Exits at Parking Facilities and Design Criteria for Permanent Parking Facilities. (Am. by ORD-12-00134, 1-2-13) (a) The design of entrances to parking facilities shall provide: 1. A sufficient distance from the nearest intersection to prevent vehicles stopping within the intersection. 2. That both permitted driveway approaches from a major street may be for ingress only with egress to a secondary street thereby eliminating vehicle back-up on the major street. 3. For ultimate one-way movement through the parking facility where there is access from two (2) or more streets and a one-way movement becomes necessary. 4. That exits onto a multi-lane street shall be either a part of an intersection or far enough away from an intersection to permit minimum hazard lane changes for left or "U" turning vehicles. 5. That exits shall not be in such proximity to a "stop" intersection as to be blocked by street vehicles stopped by the stop sign or traffic signal during any but peak traffic hours. 6. That no driveway approach shall be located where it will be used as a terminal end of a crosswalk. 7. For adequate sight distance and they shall be clearly visible to street traffic. 8. For minimum interference to street traffic at all times. (6) Design Criteria for Permanent Parking Facilities. (Am. by ORD-12-00134, 1-2-13) (a) General Requirements for Permanent Parking Facilities. Off-street parking facilities for residential lots in the Central Area with a parking area totaling two thousand (2,000) square feet or less, without an accessible parking stall, or twenty-two hundred (2,200) square feet or less, with an accessible parking stall, excluding the driveway to the parking area, are exempt from this ordinance and are subject to City Zoning Administrator review and approval. (Intro par. Cr. by Ord. 11,205, Adopted 3-21-95) 1. Each off-street parking space shall contain at least a rectangular area of a minimum width of eight (8) feet and a minimum length of eighteen (18) feet exclusive of access drives, or aisles, ramps, columns or office or work areas. Such space shall have a vertical clearance of at least seven (7) feet. However, where off-street parking spaces are provided for small vehicles, such space shall be at least seven and one-half (7½) feet in width and at least sixteen (16) feet in length and shall have a vertical clearance of at least seven (7) feet. Where the off-street parking requirement exceeds five (5) spaces, not more than twenty-five percent (25%) of the required number of spaces may be designed for small vehicles provided that any spaces designed for small vehicles shall be clearly identified by sign(s). The Director of Traffic Engineering may approve small vehicle parking spaces for up to 50 percent (50%) of the required number of spaces if the applicant proves hardship by providing a parking study and site plan demonstrating the need for small vehicle parking spaces. (Am. by ORD-11-00082, 6-16-11; Am. by ORD-23-00098, 10-26-23) 2. The typical parking facility diagrams and parking stall and drive aisle dimension table on the following pages shall determine the minimum requirements for a parking facility plan. (See Figures II—IV and Table I in Sec. 10.08(6)(b)2. through 6.) (Am. by ORD-17-00044, 4-27-17) 3. For any given parking angle between twenty (20) degrees and ninety (90) degrees not specifically listed in Figures II and III in Sec. 10.08(6)(b)2. and 3., use a table angle nearest the given angle. 4. When two (2) rows of stalls use the same drive aisle for access requiring two-way traffic because of stall layout, the drive aisle shall be a minimum of eighteen (18) feet in width or that which is called for in Figures II and III in Sec. 10.08(6)(b)2. and 3., whichever is greater. 5. No parking stall shall be so located as to require a vehicle, while exiting therefrom, to back onto any public street right-of-way, except in those parking facilities which accommodate four (4) or less parking stalls. However, alleyways may be used for ingress and egress to and from parking stalls, providing the stalls are set back the distance from the property line so that the drive aisle width is sufficient, as in recommended Figures II and III in Sec. 10.08(6)(b)2 and 3. 6. Every parking facility shall have adequate internal circulation in which no backing movement, except that required to leave a parking stall, is allowed. All parking facilities shall be designed so as not to utilize any portion of the public right-of-way except to permit ingress and egress in a forward manner; unless permitted by the Director of Traffic Engineering. (Am. by Ord. 11,533, 3-1-96; ORD-05-00128, 7-22-05; Am. by ORD-23-00098, 10-26-23) 7. The parking facility design shall be such as to furnish adequate parking for the proposed land use it serves. Adjacent street curb parking shall not be considered as part of the needed supply of parking. 8. The parking facility design shall be such as to reduce irregular and eliminate illegal traffic movements onto or in the street such as left turns, "U" turns, excessive speed in driveways and parking facilities, etc. (Am. by Ord. 11,533, 3-1-96) 9. The parking facility design shall be such as to provide maximum vehicle storage in the aisles for cars waiting to park. 10. All off-street parking facilities, except a parking space accessory to a single family dwelling, shall be improved with a bituminous, or Portland Cement concrete pavement, or paving brick surface in accordance with City of Madison standards and specifications. Such parking facilities shall be so graded and drained as to dispose of all surface water, in accordance with existing City drainage policies and ordinances. Such parking facilities shall be so arranged and marked to provide for orderly and safe parking and storage of vehicles, and shall be so designed as to prevent encroachment onto adjacent land areas, parking facilities or street rights-of-way through the use of a permanently installed, continuous six-inch (6") minimum height curbing, such as poured concrete or rolled asphalt curb (backfilled) or timbers, precast or preformed wheel stops permanently pinned in place or guardrail erected at a height of eighteen (18) inches to the center from the paved parking surface, or fencing of sufficient strength to act as a vehicle bumper stop. 11. Where applicable, screening, landscaping and vision clearance shall be provided as set forth in the City of Madison Zoning Code. 12. Outdoor lighting of off-street parking facilities shall be in conformity with Madison General Ordinances Section 10.085. (Am. by Ord. 10,631, Adopted 3-30-93) 13. Every parking facility, area and appurtenances thereto shall be maintained in a safe and sightly manner. 14. If practicable and feasible, all new building entrances shall be positioned on the site to draw traffic away from the driveway approach instead of congesting it at that point. If practicable and feasible for existing buildings, the building entrance shall also be located or relocated in the same manner for the same purpose. 15. The parking lot shall be adequately signed and marked to secure the traffic operation as planned. 16. Provision shall be made for expeditious and safe movements of pedestrians within the parking facility. 17. The Director of Traffic Engineering may alter the parking dimension minimums for residential only parking facilities, if hardship can be established by the applicant through a parking study, if the site constraints are verified, and if all standards for safe operation can be maintained. The applicant shall demonstrate safe operations by providing Traffic Engineering with dimensioned parking facility diagrams illustrating turning movements for all relevant vehicles. (Cr. by ORD-17-00044, 4-27-17; Am. by ORD-23-00098, 10-26-23) (b) 1. Figure I. CONDUIT PLACEMENT DETAILS FOR COMMERCIAL DRIVE ENTRANCES IN MADISON [image omitted; see the official code] 2. Figure II. PARKING DESIGN STANDARDS City of Madison - Traffic Engineering Division MEDIUM AND LARGE VEHICLES [image omitted; see the official code] TABLE OF DIMENSIONS (IN FEET) O | S | L | A | B | C | D | E | F | G | H | J | K 0° | 8.0 8.6 9.0 | 22.0 23.0 25.0 | 0.0 0.0 0.0 | 22.0 23.0 25.0 | 8.0 8.5 9.0 | 8.0 8.5 9.0 | 11.0 10.5 10.0 | 0.0 0.0 0.0 | 0.0 0.0 0.0 | 27.0 27.5 28.0 20° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 38.5 40.0 41.0 41.0 42.5 | 23.5 25.0 26.0 28.0 29.0 | 14.0 14.5 15.0 15.0 15.5 | 13.0 13.5 14.0 14.5 15.0 | 10.0 9.5 9.5 9.5 9.0 | 19.8 21.8 22.8 23.8 24.8 | 4.0 4.0 4.0 4.0 4.0 | 38.0 38.5 39.5 39.5 40.0 | 74.0 75.0 77.0 77.0 79.0 30° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 28.5 29.0 30.0 30.0 30.5 | 16.0 17.0 18.0 19.0 20.0 | 15.5 16.0 16.5 17.0 17.5 | 12.5 12.5 13.0 13.5 13.5 | 10.5 10.0 9.5 9.0 9.0 | 12.0 12.5 13.5 14.3 14.8 | 6.0 6.0 6.0 6.0 6.0 | 41.5 42.0 42.5 43.0 44.0 | 77.0 77.0 78.0 79.0 80.0 40° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 21.5 22.0 22.5 22.5 23.0 | 12.5 13.0 14.0 15.0 15.5 | 18.0 18.5 19.0 19.0 19.5 | 14.5 14.5 15.0 15.0 15.5 | 11.0 10.5 10.0 10.0 9.5 | 7.3 7.8 8.3 8.8 9.0 | 9.0 8.5 8.0 7.5 7.0 | 47.0 47.5 48.0 48.0 48.5 | 87.0 87.0 88.0 88.0 88.0 45° | 8.0 8.6 9.0 9.6 10.0 | 18.0 19.5 18.0 18.0 18.0 | 19.0 19.5 20.0 20.0 20.5 | 11.5 12.0 12.5 13.5 14.0 | 18.0 18.5 19.0 19.5 20.0 | 16.0 16.0 16.0 16.5 16.5 | 11.0 10.5 10.0 9.0 0.0 | 15.0 15.5 16.0 16.5 17.0 | 5.7 6.0 6.4 7.8 7.0 | 10.0 9.5 9.0 8.5 8.0 | 47.0 47.5 48.0 48.0 49.0 | 90.0 90.0 90.0 90.0 90.0 50° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 16.0 16.5 17.0 17.0 17.0 | 10.5 11.0 12.0 12.5 13.0 | 19.0 19.5 20.0 20.5 20.5 | 16.5 17.0 17.5 18.0 18.0 | 12.0 11.0 10.5 10.0 10.0 | 15.5 16.0 16.5 16.5 17.0 | 4.9 5.0 5.5 5.8 6.0 | 11.0 10.5 10.0 9.5 9.0 | 50.0 50.0 50.5 51.0 51.0 | 95.0 95.0 96.0 97.0 97.0 60° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 12.0 12.0 12.0 12.5 12.5 | 9.0 10.0 10.5 11.0 11.5 | 20.0 20.5 20.5 21.0 21.0 | 17.5 18.0 18.0 18.0 18.0 | 18.0 17.0 17.0 16.0 15.0 | 15.0 15.0 15.0 15.0 15.0 | 2.3 2.5 2.6 2.8 2.9 | 13.0 12.5 12.0 11.5 11.0 | 58.0 58.0 58.0 58.0 57.0 | 111.0 111.0 111.0 110.0 108.0 70° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 7.5 7.5 7.5 7.5 7.5 | 8.5 9.0 9.5 10.0 10.5 | 20.5 20.5 20.5 21.0 21.0 | 18.0 18.0 18.0 18.0 18.5 | 19.5 19.0 18.5 17.5 17.0 | 17.0 17.0 17.0 17.0 17.0 | 1.0 1.0 1.0 1.0 1.0 | 15.0 14.5 14.0 13.5 13.0 | 60.5 60.0 59.5 59.5 59.0 | 116.0 115.0 114.0 114.0 113.0 80° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 3.5 3.5 3.5 3.5 3.5 | 8.0 8.5 9.0 9.5 10.0 | 20.0 20.0 20.0 20.0 20.0 | 17.0 17.5 17.5 17.5 17.5 | 27.0 25.0 23.0 22.0 22.0 | 18.0 18.0 18.0 18.0 18.0 | 0.3 0.3 0.3 0.3 0.3 | 17.5 17.0 16.0 15.5 14.5 | 67.0 65.0 63.0 62.0 62.0 | 128.0 125.0 121.0 119.0 119.0 90° | 8.0 8.6 9.0 9.6 10.0 | 18.0 18.0 18.0 18.0 18.0 | 0.0 0.0 0.0 0.0 0.0 | 8.0 8.5 9.0 9.5 10.0 | 18.0 18.0 18.0 18.0 18.0 | 18.0 18.0 18.0 18.0 18.0 | 28.0 26.0 24.0 23.0 22.0 | 20.0 20.0 20.0 20.0 20.0 | 0.0 0.0 0.0 0.0 0.0 | 0.0 0.0 0.0 0.0 0.0 | 64.0 62.0 59.0 59.0 58.0 | 128.0 124.0 120.0 118.0 116.0 3. Figure III. PARKING DESIGN STANDARDS City of Madison - Traffic Engineering Division SMALL VEHICLES [image omitted; see the official code] TABLE OF DIMENSIONS (IN FEET) O | S | L | A | B | C | D | E | F | G | H | J | K 0° | 7.5 8.0 8.5 | 20.0 21.0 22.0 | 0.0 0.0 0.0 | 20.0 21.0 22.0 | 7.5 8.0 8.5 | 7.5 8.0 8.5 | 9.0 8.5 8.0 | 0.0 0.0 0.0 | 0.0 0.0 0.0 | 24.0 24.5 25.0 20° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 36.0 37.5 39.0 40.5 42.0 | 22.0 23.5 25.0 26.0 27.0 | 12.0 12.5 13.0 13.0 13.5 | 9.0 9.0 9.5 10.0 10.5 | 9.0 8.5 8.5 8.5 8.0 | 18.2 19.8 21.8 22.8 23.8 | 3.5 3.5 3.5 3.5 3.5 | 33.0 33.5 34.5 34.5 35.0 | 60.0 60.0 62.0 63.0 64.0 30° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 25.0 26.0 27.0 28.0 28.5 | 15.0 16.0 17.0 18.0 19.0 | 14.0 14.5 15.0 15.5 16.0 | 11.0 11.5 12.0 12.5 13.0 | 9.5 9.0 8.5 8.0 8.0 | 11.0 12.0 12.5 13.5 14.3 | 5.5 5.5 5.5 5.5 5.5 | 37.5 38.0 38.5 39.0 40.0 | 69.0 70.0 71.0 72.0 74.0 40° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 19.0 19.5 20.0 20.5 21.0 | 11.5 12.5 13.0 14.0 15.0 | 16.0 16.0 16.5 17.0 17.0 | 13.0 13.5 14.0 14.0 14.5 | 10.0 10.0 9.0 8.5 8.5 | 6.8 7.3 7.8 8.3 8.8 | 8.0 7.5 7.5 7.0 6.5 | 42.0 42.0 42.0 42.5 42.5 | 78.0 79.0 79.0 79.0 80.0 45° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 17.0 17.0 17.5 18.0 18.5 | 10.5 11.0 12.0 13.0 13.5 | 16.5 17.0 17.0 17.5 18.0 | 14.0 14.0 14.5 15.0 15.5 | 10.0 9.5 9.5 8.5 8.0 | 13.0 13.5 14.0 14.5 15.0 | 5.2 5.7 6.0 6.4 6.8 | 9.0 8.5 8.0 7.5 7.5 | 43.0 43.5 43.5 43.5 44.0 | 81.0 81.0 82.0 82.0 83.0 50° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 14.5 15.0 15.0 15.5 16.0 | 10.0 10.5 11.0 12.0 12.5 | 17.0 17.5 18.0 18.0 18.5 | 15.0 15.0 15.5 15.5 16.0 | 11.0 10.5 10.0 10.0 9.0 | 13.5 14.0 14.5 14.5 15.0 | 4.5 4.9 5.0 5.5 4.8 | 10.0 9.5 9.0 8.5 8.0 | 45.0 45.5 46.0 46.0 46.0 | 86.0 86.0 87.0 87.0 87.0 60° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 10.0 10.5 10.5 11.0 11.0 | 8.5 9.0 10.0 10.5 11.0 | 18.0 18.0 18.0 18.5 18.5 | 15.5 16.0 16.5 16.5 17.0 | 17.0 16.5 16.0 15.5 15.0 | 13.0 13.0 13.0 13.0 13.0 | 2.0 2.3 2.5 2.6 2.8 | 11.5 11.5 11.0 10.5 10.0 | 53.0 52.5 52.0 52.0 52.0 | 101.0 101.0 101.0 101.0 101.0 70° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 6.5 6.5 6.5 6.5 6.5 | 8.0 8.5 9.0 9.5 10.0 | 18.0 18.0 18.0 18.5 18.5 | 16.0 16.5 16.5 17.0 17.0 | 18.0 17.0 17.0 16.0 16.0 | 15.0 15.0 15.0 15.0 15.0 | 1.0 1.0 1.0 1.0 1.0 | 13.5 13.0 12.5 12.0 11.5 | 54.0 53.0 53.0 53.0 53.0 | 104.0 103.0 103.0 103.0 103.0 80° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 3.0 3.0 3.0 3.0 3.0 | 7.5 8.0 8.5 9.0 8.5 | 18.0 18.0 18.0 18.0 18.0 | 16.5 16.5 16.5 17.0 17.0 | 24.0 22.0 21.0 20.0 19.0 | 16.0 16.0 16.0 16.0 16.0 | 0.3 0.3 0.3 0.3 0.3 | 15.5 15.5 14.5 14.0 13.0 | 60.0 58.0 57.0 56.0 55.0 | 117.0 113.0 111.0 110.0 108.0 90° | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 0.0 0.0 0.0 0.0 0.0 | 7.5 8.0 8.5 9.0 9.5 | 16.0 16.0 16.0 16.0 16.0 | 16.0 16.0 16.0 16.0 16.0 | 25.0 23.0 22.0 21.0 20.0 | 18.0 18.0 18.0 18.0 18.0 | 0.0 0.0 0.0 0.0 0.0 | 0.0 0.0 0.0 0.0 0.0 | 57.0 55.0 54.0 53.0 52.0 | 114.0 110.0 108.0 106.0 104.0 4. Figure IV. PARKING DESIGN STANDARDS City of Madison - Traffic Engineering Division ONE-SIZE-FITS-ALL [image omitted; see the official code] TABLE OF DIMENSIONS (IN FEET) O | S | L | A | B | C | D | E | F | G | H | J | K 0° | 8.75 | 24.0 | 0.0 | 24.0 | 8.75 | 8.75 | 10.5 | 0.0 | 0.0 | 28.0 20° | 8.75 | 17.0 | 38.6 | 25.6 | 14.1 | 10.0 | 9.5 | 22.6 | 4.0 | 37.7 | 67.2 30° | 8.75 | 17.0 | 27.9 | 17.6 | 16.1 | 12.3 | 9.6 | 13.1 | 6.0 | 41.8 | 76.0 40° | 8.75 | 17.0 | 21.1 | 13.7 | 17.7 | 14.3 | 10.0 | 8.0 | 8.0 | 45.4 | 84.0 45° | 8.75 | 17.0 | 18.3 | 12.4 | 18.3 | 15.2 | 10.0 | 16.0 | 6.2 | 9.0 | 46.6 | 87.0 50° | 8.75 | 17.0 | 15.7 | 11.5 | 18.7 | 15.9 | 10.5 | 16.5 | 4.7 | 10.0 | 47.9 | 90.2 60° | 8.75 | 17.0 | 11.1 | 10.2 | 19.1 | 17.0 | 17.0 | 15.0 | 2.5 | 12.0 | 55.2 | 106.2 70° | 8.75 | 17.0 | 7.0 | 9.4 | 19.0 | 17.5 | 18.0 | 17.0 | 1.1 | 14.0 | 56.0 | 109.0 80° | 8.75 | 17.0 | 3.3 | 8.9 | 18.3 | 17.6 | 23.0 | 18.0 | 0.3 | 16.0 | 59.6 | 117.8 90° | 8.75 | 17.0 | 0.0 | 8.8 | 17.0 | 17.0 | 23.0 | 20.0 | 0.0 | 0.0 | 57.0 | 114.0 5. Table I. Parking Design Standards for Other Types of Vehicle Spaces (in Feet) Type of Vehicles | Width of Stall | Length of Stall | Two-Way Access Aisle | Turning Radius Wall to Wall Outside Front Motorcycle | 5 | 10 | 10 Moped | 3 | 6 | 5 Buses (Vert. CL. 14') | 12 | 40 | 30 | 47 Semitrailers WB-40 or WB-50 | 12 | 50 or 55 | 30 - 40 | 40 - 60 Recreational Vehicles | 10 | 30 | 30 | 44 6. Figure V. PARKING DESIGN STANDARDS City of Madison - Traffic Engineering Division LOADING DOCKS [image omitted; see the official code] TABLE OF DIMENSIONS (IN FEET) LOADING DOCK DIMENSIONS Design Vehicle | Length in Feet | Dock Angle (a) | Clearance in Feet | Berth Width in Feet | Apron Space in Feet | Total Offset in Feet WB-40 | 50 | 90 | 50 | 10 | 63 | 113 12 | 56 | 106 14 | 52 | 102 60 | 44 | 10 | 46 | 90 12 | 40 | 84 14 | 35 | 79 45 | 36 | 10 | 37 | 73 12 | 32 | 68 14 | 29 | 65 WB-50 | 55 | 90 | 55 | 10 | 77 | 132 12 | 72 | 127 14 | 67 | 122 60 | 48 | 10 | 55 | 103 12 | 51 | 99 14 | 46 | 94 45 | 39 | 10 | 45 | 84 12 | 40 | 79 14 | 37 | 76 (c) (R. by ORD-12-00134, 1-2-13). (d) Car washes shall be designed to provide the following: 1. Parking and Reservoir Space Requirements. a. One parking space for each two employees, and one parking space for the owner or manager of any car wash. b. Reservoir parking spaces equal in number to five (5) times the maximum capacity of a self-service or any other car wash shall be provided: maximum capacity, in this instance, shall be defined as the greatest possible number of automobiles undergoing some phase of laundering at the same time, which shall be determined by dividing the length in feet of each production line by twenty (20). c. One additional space shall be provided for each nozzle of any vacuum cleaning machine, while storage space for other car washes shall be adequate to accommodate all vehicles off-street which are awaiting delivery. d. Self-service car washes without indoor drying equipment shall provide one drying area stall for each self-service car wash stall to be located outside the area of any exit lane or area used for any other laundering process. 2. The exit door of any car wash shall be at least twenty-five (25) feet from any street or alley lot line. 3. For a self-service or full-service car wash having some type of indoor drying equipment the exit door shall be at least forty (40) feet beyond such dryers. However, the Director of the Building Inspection Division may reduce this distance requirement when the applicant provides a noise study demonstrating that the sound levels of the indoor drying equipment and car wash equipment do not exceed 65 decibels (dbs) between 7:00 a.m. and 7:00 p.m. and 60 decibels (dbs) between 7:00 p.m. and 7:00 a.m. at a residential property line, and meets Section 24.08, Madison General Ordinances, and all other requirements. (Am. by ORD-08-00109, 10-7-08) 4. The off-street facility shall make provisions for adequate queue storage that prevents queue interference with pedestrian or other vehicular movement and shall supply a queuing model to the Director of Traffic Engineering for approval. (Am. by ORD-23-00098, 10-26-23) 5. Any exterior lighting shall be in conformity with Madison General Ordinances Section 10.085(6)(a)12. 6. The hours of operation shall be limited to the hours between 7:00 a.m. and 9:00 p.m. Exceptions to these hours are subject to City Plan Commission review and approval under Section 28.183. 7. A reasonable means, approved by the Director of the Building Inspection Division to prevent the drainage or deposition of water which may create icing conditions, or the drainage or deposition of other cleaning material which may create undesirable conditions in the storm drainage system, from these premises or from any vehicle so serviced on such premises upon any public sidewalk, street or right-of-way of the City of Madison. Reasonable means may include, but are not limited to, drainage pits, areas or racks, mechanical shakers, compressed air blasts, fan blowers, etc. which will dry or remove water or other liquid material from the underside of the vehicle. (Am. by ORD-08-00109, 10-7-08) 8. All of the provisions of this subdivision shall be prospective in operation and shall apply to the granting of all building permits for the construction of car washes and all building permits for alterations to, enlargements of and remodeling of existing building, provided, however, that paragraph 7. of this subdivision shall be applicable to existing car washes now in operation and such existing car washes shall comply with the subdivision. (7) Application. (a) All applications for Class III, IIIa, IV and commercial site driveway approach permits shall be made at the office of the Director of Traffic Engineering on a form prescribed by the Board. Applications for commercial driveway approach permits that are proposed as part of a Planned Commercial Development, Planned Urban Development, Conditional Use application, or other application under Chapter 28, may be filed with the Zoning Administrator. (Am. by Ord. 13,489, 1-23-04; Am. by ORD-23-00098, 10-26-23) (b) All applications for driveway approaches except Class I and Class II to parking and loading facilities shall be accompanied by scaled drawings, in quintuplicate, and approved by the respective City departments before a building permit will be issued. The following items must be indicated and dimensioned on the five submitted drawings: 1. A scaled drawing plot plan on a single sheet (1" = 20') or larger. 2. Address and parcel number of property. 3. Property lines, existing and proposed structures. 4. Width of abutting rights-of-way, roadways and terraces. 5. Location of driveway approaches-existing, proposed and adjoining. 6. Proposed driveway radii. 7. Type of surface-driveway approach, driveway and parking lot. 8. Proposed routing of motor vehicles entering and leaving. 9. Proposed treatment of right-of-way area adjacent to or between approaches. 10. Rate of slope or grade of approaches and driveways. 11. Utility poles, fire hydrants, or other structures to be moved. (Am. by ORD-25-00071, 10-16-25) 12. Means of separation between parking lot and sidewalk. 13. Number, arrangement and size of parking stalls. 14. Proposed parking facility lighting in conformity with Madison General Ordinances Section 10,085. (Am. by Ord. 10,631, Adopted 3-30-93) 15. Distance to intersecting streets within five hundred (500) feet and location, elevation and size of all storm sewers available. 16. Indicate elevation of existing site to City datum. Elevations to be spotted at twenty-five (25) foot intervals or one (1) foot contours. 17. If no storm sewers are available, the owner is to include elevation of the top of the curb. 18. If the street is unimproved, the plot plan is to indicate the location and elevation of the drainage ditches abutting the site and proposed street centerline elevation. 19. Proposed method of drainage including the following: a. Proposed finished elevations of parking lot, including direction of drainage and elevations of proposed gutters or swales. b. Elevations, location and size of inlets, catch basin and storm sewers to be constructed in conjunction with the parking lots. 20. Location of all downspouts from the building and proposed method of disposing of surface water. 21. Name and address of person responsible for paying storm sewer connection charges that may be levied in conjunction with this project. 22. The applicant shall identify all street trees within the adjoining right-of-way and whether the trees, including their root structures, will be impacted by the proposed driveway approach. When identifying any impacted trees, the applicant must identify the species of the impacted trees and the DBH or caliper measurement of the tree, as those terms are defined in Sec. 10.105(2). (Cr. by ORD-25-00071, 10-16-25) (c) Application for residential driveway approaches shall be made at the City Engineering Division and shall identify all street trees within the adjoining right-of-way and whether the trees, including their root structures, will be impacted by the proposed driveway approach. When identifying any impacted trees, the applicant must identify the species of the impacted trees and the DBH or caliper measurement of the tree, as those terms are defined in Sec. 10.105(2). Application for commercial driveway approaches to off-street vehicle facilities shall be made at the Traffic Engineering Division. (Am. by ORD-25-00071, 10-16-25) (d) Before any Class III, III(a) or IV driveway approach permit for the construction or reconstruction of an off-street parking facility is granted under any ordinance, the applicant shall indicate on such application the location of proposed entrances and exits for the accommodation of motor vehicles entering and leaving said facility, together with the proposed plan of routing of motor vehicles entering and leaving said facility. Said application shall then be referred to the Traffic Engineering Division, City Engineering Division, and the Building Inspection Division of the Department of Planning and Community and Economic Development for their approval. (Am. by Ord. 8081, 7-29-83; ORD-08-00109, 10-7-08) (e) On receipt and approval of the permit application and appropriate fee(s) under Sec. 10.08(8)(f) below, a permit shall be granted for construction which shall conform to the application. Driveway and parking lot permits shall not be granted or shall be deemed void for any parcel, lot or property which has not been legally divided per City of Madison ordinances. (Am. by Ord. 13,489, 1-23-04) (f) Permit Fees for Certain Classes of Driveway Approaches. The minimum fee for the review, issuance and inspection of a permit for a single address with a Class I or II driveway approach, sidewalk or terrace improvements shall be twenty-five dollars ($25). The fee for a permit issued after commencing work, expect in cases of emergency as determined by the Engineer, shall be double the fees. The fee for referral of the aforementioned permit that has automatically terminated under Sec. 10.08(8)(a) shall be twenty-five dollars ($25). The fee for the review and issuance of a permit for each Class III, IIIa, IV and commercial site driveway approach shall be $100 for each new approach, modification or reconstruction of an existing approach, removal or closure of an existing approach, including those required under Sec. 10.08(8)(h); or change of class under Sec. 10.08(8)(f). The $100 fee shall apply to each separate driveway approach so approved, whether approved on a single permit form or multiple forms. The fee for renewal of a permit that has automatically terminated under Sec. 10.08(8)(a) shall be $50 for each separate driveway approach for which renewal is requested. (Cr. by Ord. 13,489, 1-23-04; Am. by ORD-14-00053, 3-12-14) (8) Restrictions and Responsibilities. (a) Driveway approaches and parking facility requirements must be completed within one (1) year after the permit is issued; otherwise the permit shall automatically terminate. The permit may be renewed prior to the termination date, for a period not to exceed one (1) additional year, by payment of the fee under sec. 10.08(7)(f). (Am. by Ord. 13,489, 1-23-04) (b) The construction of such driveway and approaches shall not interfere with any existing structure on any street right-of-way without specific permission in writing from the Board and other owner thereof. The trimming, pruning and removal of any street tree shall require the prior issuance of a permit under Section 10.101 and compliance with Section 10.105. (Am. by ORD-25-00071, 10-16-25) (c) The permittee shall assume all responsibility for any injury or damage to persons or property resulting directly or indirectly during the construction of any approach or driveway, including the injury or damage to any street tree. (Am. by ORD-25-00071, 10-16-25) (d) The permittee shall assume responsibility for all maintenance of such driveway approaches from the right-of-way line to the edge of the traveled roadway. (e) No entrance or approach shall be relocated or its dimensions altered unless a new permit authorizing the relocation or reconstruction is issued for the appropriate driveway approach under Sec. 10.08(7). (Am. by Ord. 13,489, 1-23-04) (f) A driveway entrance and approach constructed for one class shall not be used under a different class until the appropriate permit for such different class at that location is issued under Sec. 10.08(7). (Am. by Ord. 13,489, 1-23-04) (g) Where a permit has been granted for entrances to a parking facility, or the Director of Traffic Engineering has approved a site plan for a new or existing parking facility, said facility shall not be altered or the plan of operation changed until a revised plan has been submitted and approved as specified in Subsection (6) or (7), as appropriate. The circumstances under which a parking facility shall be considered to have been altered shall include, but are not limited to: any portion or element of the facility as shown on the approved plan is not constructed or completed according to the approved plan, or if any moveable fixtures or features of the facility are located other than as shown on the approved plan. The circumstances under which the plan of operation shall be considered to have changed shall include but are not limited to: vehicles parked beyond the limits of the approved plan, in areas or in a manner other than as designated on the plan, vehicles allowed to circulate, make ingress or egress in any manner other than was shown on the approved plan, excess vehicle storage or other non-vehicle items permitted to be stored that were not approved on the plan, or in a place other than where approved on the plan. (Am. by Ord. 12,865, 8-7-01; Ord. 13,489, 1-23-04; Am. by ORD-23-00098, 10-26-23) (h) Application for a permit to construct or reconstruct any driveway entrance and approach to a site shall also be deemed a request for a permit to reconstruct or close any existing nonconforming or unused entrances and approaches to the same site. No permit to construct a new driveway approach or reconstruct any existing approach shall be granted unless the applicant agrees to properly reconstruct or close any other existing nonconforming or unused entrances or approaches on the site and permits are issued for the same under Sec. 10.08(7). All costs incurred shall be at the expense of the property owner. (Am. by Ord. 13,489, 1-23-04) (i) Where a driveway approach is no longer used or no longer leads to a driveway, residence, barn, garage, parking facility or other improved area for the lawful use of vehicles, by reason of abandonment, construction, reconstruction or change of land use, such approaches shall be removed and standard curb and gutter replaced at the expense of the property owner and shall be completed within one (1) year after issuance of the appropriate permits under this section. (Am. by Ord. 13,489, 1-23-04) (j) When a building permit is required for the reconstruction or remodeling of an existing commercial site or a zoning or occupancy certificate is required for use or change of use for any land, buildings or structures, all of the existing, as well as the proposed, driveway approaches and parking facilities shall comply with all design standards as set forth in this ordinance. (k) No person shall construct a new driveway approach, modify or reconstruct an existing approach, remove or close an existing approach, change the class of an approach, work on any driveway approach for which a permit has automatically terminated under Sec. 10.08(8)(a), or cause any of the above to take place, without the appropriate valid permit(s) issued therefore. This provision shall apply equally to the owner or occupant of the property that the driveway approach leads to and any person performing the construction or work on the driveway approach in question. (Cr. by Ord. 13,489, 1-23-04) (l) Except for owners of buildings with four (4) or fewer units that are zoned residential, no person shall perform any work on any driveway or driveway approaches within the public right-of-way without holding a license under Sec. 9.20(1)(a). (Cr. by ORD-15-00006, 1-14-15) (m) Tree Protection. For any trees within the right-of-way adjacent to the permitted driveway entrance and approach area that are not the subject of a tree trimming, pruning or removal permit issued under Sec. 10.101, the permittee shall comply with Section 107.13, the Tree Protection Specifications, of the City's Standard Specifications for Public Works Construction, where applicable, while performing work on the authorized driveway entrance and approach. (Cr. by ORD-25-00071, 10-16-25) (9) Administration. (a) The Board is hereby authorized to prescribe the form of bond and the form of application for permits under this section and shall have general supervision of the enforcement of the provisions of this section. It shall have authority to make such rules and regulations, consistent with the provisions of this section and law, as may be necessary for the proper administration and enforcement of this section. (b) If approval of any proposed driveway approach or proposed parking lot and driveway approach is denied, the applicant, owner lessor or lessee may appeal to the Board of Public Works for a review of the denial by filing notice of appeal with the City Clerk within thirty (30) days after such denial. The Notice of Appeal shall state the basis or bases upon which the applicant seeks review of the denial. At such hearing the applicant shall have the opportunity to cross examine witnesses, may call witnesses in their own behalf and may be represented by legal counsel. After holding a hearing, the Board shall by majority vote make findings of fact and conclusions of law and may by majority vote affirm, modify or reverse the denial of the driveway approach or parking lot and driveway approach consistent with the provisions of this section. The Board shall have only the power to determine whether staff has properly interpreted the provisions of this section and may not modify, change or substitute for any provision contained in these ordinances. (Am. by Ord. 11,007, 10-12-94) (c) Inspection to determine compliance within the terms of this ordinance shall be the responsibility of the Building Inspection Division of the Department of Planning and Community and Economic Development. (Am. by Ord. 8081, 7-29-83; ORD-08-00109, 10-7-08) (d) (Rpld. by ORD-25-00071, 10-16-25) (10) Penalties. (a) Except as provided in Subdivision (b), any person violating the provisions of this section shall be fined not less than twenty-five dollars ($25) nor more than two hundred dollars ($200) and each day of continued violation shall constitute a separate offense. (b) The failure to comply with the Tree Protection Specifications as required under Subsection (8)(m) shall, in addition to the requirements of Section 10.105, be subject to a forfeiture of five hundred dollars ($500), unless the violation results in the removal of a tree, in which case the forfeiture shall be one hundred and fifty dollars ($150) per trunk diameter inch of the impacted tree, as measured or estimated at 4½ feet above the ground and rounded down to the nearest inch. Each day such violation or failure to comply continues shall be considered a separate offense.
(Sec. 10.08(6)(b)1. Am. by Ord. 9516, 7-6-88) (Sec. 10.08(6)(b)4. Cr. by ORD-17-00044, 4-27-17) (Sec. 10.08(6)(b)5. Cr. by ORD-17-00044, 4-27-17) (Sec. 10.08(6)(d) Am. by Ord. 12,008, 1-15-98; ORD-12-00134, 1-2-13) (Sec. 10.08 Am. by Ord. 7204, 1-22-81; Rpld. & Recr. by ORD-25-00071, 10-16-25)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.
