§ 15.08.020 — Code amended
Henderson Municipal Code (Supp. No. 59: codified through Ordinance No. 4163, adopted June 16, 2026) · Henderson Municipal Code § 15.08.020
Corpus is an independent public-information project, not the official City of Henderson website. Stable reference: corpuslaw.us/code/b1a73b46-5392-44f1-bda4-38b93174d7c8
15.08.020 - Code amended.
The City of Henderson adopts as an amendment to the 2024 International Building Code the booklet entitled Southern Nevada Proposed Amendments to the 2024 International Building Code, is adopted in its entirety excepting amendments and changes as stated in this chapter. This booklet is available on the city's website(s). The booklet is further amended by replacing the definition of ventilation well in Section 202, by replacing section 406.5.2.2 and by replacing Section 504.4 as follows: VENTILATION WELL. A vertical open area used to provide natural ventilation with an unobstructed opening to sky at the top. The well is bound on three sides by walls with the fourth side having openings to the structure requiring natural ventilation. 406.5.2.2 Opening above grade. When ventilation wells are used to satisfy natural ventilation requirements for open parking garages, the width of the ventilation well opening to sky shall be one and one-half times the height of the adjacent structure to the bottom of the lowest required opening. The minimum required width of the ventilation well shall be maintained for not less than the length of the required openings. The width of the ventilation well is not required to exceed 30-feet. The building shall be provided with a horizontal air intake opening at the bottom not less than 160 square feet and leading to the exterior of the building surrounding the open parking garage. Exception: The ventilation well opening width is not restricted if any of the following are met or provided: 1. Supplemental mechanical ventilation meeting the requirements of Section 406.6.2 is provided for the open parking garage. 2. An engineering analysis proving equivalent natural ventilation requirements are met. 504.4 Number of Stories. The maximum number of stories of a building shall not exceed the limits specified in Table 504.4.
(Ord. No. 4137, § 2, 12-16-2025; Ord. No. 4083, § 3, 7-15-2025; Ord. No. 3907, § 2, 9-13-2022; Ord. No. 3824, § 2, 12-7-2021; Ord. No. 3669, § 2, 3-3-2020; Ord. No. 3504, § 1, 8-7-2018; Ord. No. 3040, § 1, 8-6-2013; Ord. No. 2898, § 2, 1-18-2011)
Ask a question about Henderson law
Corpus searches the Henderson sections it holds and shows the ones that match, with their citations. Free, no sign-in.
