§ 10-62 — Amendments to the adopted chapters of the International Mechanical Code(2024)

San Antonio City Code (Supp. No. 147: codified through Ordinance No. 2026-09-10-547, adopted Sept. 10, 2026) · San Antonio City Code § 10-62

Corpus is an independent public-information project, not the official City of San Antonio website. Stable reference: corpuslaw.us/code/b1ad883f-1a9a-49a0-b1c8-cbe1bf7a6da5

Sec. 10-62. - Amendments to the adopted chapters of the International Mechanical Code(2024).

Additions to the International Mechanical Code (IMC) are shown asunderlined text. Deletions of the IMC are shown as bracketed [strikethroughs]. Section 202, GENERAL DEFINITIONS, is amended by adding the following definition: NFPA 70. The National Electrical Code, as amended by Article VI of this Code. Section 301.10, Electrical, is amended as follows: 301.10 Electrical. Electrical wiring, controls and connections to equipment and appliances regulated by this code shall be in accordance with NFPA 70. All wiring, including control wiring, exposed to weather shall be installed in a raceway approved for the environment. Section 304, INSTALLATION, is amended by adding Section 304.13 Installation at gas valve, as follows: 304.13 Installation at gas valve. Minimum Schedule 40 metallic pipe shall be installed at the gas valve and extended a minimum of two inches outside the gas furnace and gas rooftop unit's casing and may be connected to an approved listed flexible gas connector. Section 306.3, Appliances in attics, is amended by adding 306.3.2 Access for cooling or heating appliance, as follows: 306.3.2 Access for cooling or heating appliance. For one-and two-family residential occupancies and townhomes with newly installed cooling or heating appliances in the attic space, a permanent ladder, fold-away ladder, or direct access door opening from the house on the same floor level shall be installed. Section 307.2.1, Condensate disposal, is deleted and replaced with the following text: 307.2.1 Condensate disposal. Condensate disposal shall be in accordance with Chapter 34, Section 34-274 of the City Code of San Antonio. [Condensate from all cooling coils and evaporators shall be conveyed from the drain pan outlet to an approved place of disposal. Such piping shall maintain a minimum horizontal slope in the direction of discharge of not less than one-eighth unit vertical in 12 units horizontal (1-percent slope). Condensate shall not discharge into a street, alley or other areas so as to cause a nuisance.] Section 307.2.1.1, Condensate discharge, is amended as follows: 307.2.1.1 Condensate discharge. Condensate drains shall not directly connect to any plumbing drain, waste, or vent pipe. Condensate drains shall not discharge into a plumbing fixture other than a floor sink, floor drain, trench drain, mop sink, hub drain, standpipe, utility sink or laundry sink. Condensate drain connections to a lavatory wye branch tailpiece or to a bathtub overflow pipe shall not be considered as discharging to a plumbing fixture. Except where [discharging to grade outdoors] installed per Chapter 34, Section 34-274 of the City Code of San Antonio, the point of discharge of condensate drains shall be located within the same occupancy, tenant space or dwelling unit as the source of the condensate. Section 30fv 07.2.2, Drain pipe materials and sizes, is amended as follows; All other code text remains as is: 307.2.2 Drain pipe materials and sizes. Components of the condensate disposal system shall be ABS, cast iron, copper, and copper alloy, CPVC, cross-linked polyethylene, galvanized steel, PE-RT, polyethylene, polypropylene, PVC or PVDF pipe or tubing. Components shall be selected for the pressure and temperature rating of the installation. Joints and connections shall be made in accordance with the applicable provisions of Chapter 7 of the International Plumbing Code relative to the material type. Condensate waste and drain line size shall be not less than ¾-inch pipe size and shall not decrease in size from the drain pan connection to the place of condensate disposal. Where the drain pipes from more than one unit are manifolded together for condensate drainage, the pipe or tubing shall be sized in accordance with Table 307.2.2. Primary drain lines located in any unconditioned space, except for crawl spaces, shall be insulated with foam plastic rubber-based insulation or approved material with a minimum thickness of ⅜ inch. Section 307.2.4.1, Ductless mini-split system traps, is amended as follows: 307.2.4.1 Ductless mini-split system traps. Ductless mini-split equipment that produces condensate shall be [provided with an in-line check valve located in the drain line, or a trap] in accordance with their manufacturers' recommendations. Section 504.4.1, Termination location, is amended as follows: 504.4.1 Termination location. Exhaust duct terminations shall be in accordance with the dryer manufacturer's installation instructions. Where the manufacturer's instructions do not specify a termination location, the exhaust duct shall terminate not less than 3 feet (914 mm) in any direction from openings into buildings, including openings in ventilated soffits or any mechanical equipment. Section 606.2, Where required, is amended as follows; All other code text remains as is: 606.2 Where required. Smoke detectors shall be installed where indicated in Section 606.2.1 through 606.2.3 or in accordance with NFPA 90A "Standard for the Installation of Air Conditioning and Ventilating Systems." Section 1006.6, Safety and relief valve discharge, is amended to read as follows: 1006.6 Safety and relief valve discharge. Safety and relief valve discharge pipes shall be of rigid pipe that is approved for the temperature of the system. High-pressure-steam safety valves shall be vented to the outside of the structure. The discharge piping serving pressure relief valves, temperature relief valves and combinations of such valves shall: 1. Not be directly connected to the drainage system. 2. Discharge through an air [break] gap located in the same room as the appliance. 3. Not be smaller than the diameter of the outlet of the valve served and shall discharge full size to the air [break] gap. 4. Serve a single relief device and shall not connect to piping serving any other relief device or equipment. 5. Discharge to [the floor, to the pan serving the boiler or storage tank, to] a waste receptor or to the outdoors. Discharge to the floor of a garage or basement will only be allowed if approved by the code official. Terminate to the exterior a minimum of six inches (152 mm) and a maximum of 12 inches (304 mm) above the finish grade. 6. Discharge in a manner that does not cause personal injury or structural damage. 7. Discharge to a termination point that is accessible [readily visible and observable by the building occupants]. If the discharge termination point is not readily visible and observable, a leak detection monitoring device with alarm notification (and not automatic shut-off) is required. 8. Not be trapped. 9. To be installed to flow by gravity. 10. Terminate not more than 6 inches (152 mm) above the floor or flood level rim of the waste receptor. 11. Not have a threaded connection at the end of the piping. 12. Not have valves or tee fittings. 13. Utilize piping material complying with Section 1202 14. Union or flex connector on temperature pressure relief valve shall be placed within six inches (1522 mm) of the valve for removal and replacement. Section 1101.7, Changing refrigerant, is amended to read as follows; All other code text remains as is: 1101.7 Changing refrigerant. Changes of refrigerant in an existing system to a refrigerant with a different refrigerant designation or containing more than 220 pounds (99.8 kg) of Group A1 shall be allowed only where in accordance with the following: Section 1101.9, Locking access port caps, is amended to read as follows: 1101.9 Locking Access port caps. Refrigerant circuit access ports located outdoors shall be fitted with locking-type tamper-resistant caps or shall be otherwise secured to prevent unauthorized access. This section shall not apply to refrigerant circuit access ports on equipment installed in controlled areas such as on roofs with locked access hatches or doors. Section 1102.3, Access port protection, is repealed in its entirety. Section 1109.2.5, Refrigerant pipe shafts, is amended to read as follows: 1109.2.5 Refrigerant pipe shafts. Refrigerant piping that penetrates two or more floor/ceiling assemblies shall be enclosed in a fire-resistance-rated shaft enclosure. The fire-resistance-rated shaft enclosure shall comply with Section 713 of the International Building Code. Exceptions: 1. Refrigeration systems using R-718 refrigerant (water). 2. Piping in a single direct refrigeration system [using Group A1 refrigerant] where the refrigerant quantity does not exceed the limits of Table 1103.1 for the smallest occupied space through which the piping passes. 3. Piping located on the exterior of the building where vented to the outdoors.

(Ord. No. 2025-01-30-0075, § 1(Att. 1), 1-30-25)

Ask a question about San Antonio law

Corpus searches the San Antonio sections it holds and shows the ones that match, with their citations. Free, no sign-in.