§ 49-1607 — Relief valves and settings
Omaha Municipal Code (Supp. No. 100, Update 2: codified through Ordinance No. 44760, enacted August 4, 2026) · Omaha Municipal Code § 49-1607
Corpus is an independent public-information project, not the official City of Omaha website. Stable reference: corpuslaw.us/code/b2ce7220-1e37-4c34-9f48-4e3092b2a27d
Sec. 49-1607. - Relief valves and settings.
Every water heater or storage tank shall be protected with a temperature relief valve and a pressure relief valve (or a combination temperature and pressure relief valve) and incorporate the following provisions: (a) A relief valve shall have a minimum rated capacity for the equipment it serves. (1) Temperature relief valves shall be set at no more than 210 degrees Fahrenheit. (2) Pressure relief valves shall be set at the pressure rating of the water heater or storage tank, whichever is less, but shall not exceed 150 psig. (b) The following provisions shall be applied to the installation of relief valves: (1) The temperature or temperature-pressure relief valve shall be fully automatic, reseating. (2) The temperature or temperature pressure relief valve shall be installed in a tapping in the top of the tank or in the side of the tank not more than six inches below the top. (3) There shall not be a shut-off of any type between the relief valve and the water heater or on the discharge side of the relief valve. (c) The following provisions shall be applied to the discharge of relief valves: (1) Materials used for the discharge of the relief valve shall be rigid copper or steel materials as approved elsewhere in this chapter. (2) Relief valves shall be piped full size of the outlet and installed to drain by gravity flow independently of any other relief valve or indirect drain. The outlet pipe shall run to an approved receiving fixture sufficient to receive the maximum discharge from the valve. (3) If the discharge pipe exceeds a developed length of 30 feet, or has more than four 90-degree elbows, it shall be increased one size. (4) In new construction, a floor drain or floor sink shall be located immediately adjacent to the water heater when possible. When not possible, the floor drain or floor sink shall be located no further than five feet from the water heater. (5) Relief valves shall discharge to within six inches of the floor or discharge to a floor drain or floor sink (or other approved plumbing fixture) through an air gap. Relief valves shall not discharge so as to be a hazard, a potential cause of damage or otherwise a nuisance. (6) The end of the discharge pipe shall not be threaded.
(Ord. No. 40524, § 1, 10-20-15)
Ask a question about Omaha law
Corpus searches the Omaha sections it holds and shows the ones that match, with their citations. Free, no sign-in.