§ 15-5-10 — OSSF REGULATIONS
Austin City Code (Supp. No. 174: codified through Ordinance No. 20260521-050, effective June 1, 2026) · Austin City Code § 15-5-10
Corpus is an independent public-information project, not the official City of Austin website. Stable reference: corpuslaw.us/code/b38c3879-38b8-4265-ba9a-a6f0d541de2c
§ 15-5-10 - OSSF REGULATIONS.
(A) A designer shall inspect the installation of the OSSF and provide written certification to the City that the OSSF was installed in accordance with the approved planning materials. Designer certification and as-built plans must be submitted to the City prior to the final inspection. (B) The Director may from time to time administratively adopt non-substantive requirements for applications, permitting, licensing, an inspections for OSSFs. (C) For a property served by an existing holding tank, when other methods of sewage disposal become feasible in the opinion of the Director, the property is required to connect to the feasible alternative, within 90 days of written notice by the City. Examples of feasibility include, but are not limited to, the development of a private or public wastewater collection system within 100 feet in horizontal distance of the property or technological advancements to OSSFs that allow an alternative treatment and disposal system to be installed on the property. (D) This subsection establishes sizing requirements for lots using OSSFs. (1) Subdivisions of single-family dwellings platted or created after October 14, 2013, and located within the Edwards Aquifer Recharge Zone or the Edwards Aquifer Contributing Zone, must have lots of: (a) at least 1 acre if served by public water system, or (b) at least 2 acres if served by private water supply. (2) Subdivisions of single-family dwellings platted or created after October 14, 2013, that are located within all other areas not subject to Paragraph (D)(1) of this subsection must have lots of: (a) at least 0.75 acres if served by public water system, or (b) at least 1 acre if served by private water supply. (3) When more than one residence with separate OSSFs are proposed on a single tract of land, that land must meet the minimum lot size requirements for the number of residences or structures. (E) This subsection establishes requirements for the maintenance of OSSFs. (1) Requirements for homeowners providing maintenance of OSSF: (a) At the end of the initial two-year service policy, an owner of a single-family owner-occupied residence (homeowner) utilizing an OSSF that requires maintenance, as specified in Table XII of 30 TAC Chapter 285, may only perform maintenance on the OSSF if they: (i) have taken the training to be a TCEQ registered maintenance technician, as required in 30 TAC Chapter 30, Section 30.245(b); or (ii) have taken an equivalent training specifically for homeowners, as determined by the City; and (iii) are registered with the City as a Homeowner Maintenance Provider. (b) Homeowners that perform maintenance on their own OSSF must submit to the City the same reports that are required for licensed maintenance providers by the TCEQ. (c) Within one year of receiving a written notice from the City, a homeowner who has previously maintained an existing OSSF that requires a maintenance affidavit must comply with the maintenance and reporting requirements of 30 TAC, Chapter 285, and this Subsection even if compliance was not previously required. (d) A copy of the results of all testing related to the maintenance of OSSFs, including analytical results, must be provided to the City. (e) Failure to comply with TCEQ's reporting requirements for TCEQ licensed maintenance providers, as specified in 30 TAC Section 285.7 may result in the revocation of a homeowner's City registration. (f) A Homeowner Maintenance Provider whose registration has been revoked must secure the services of a TCEQ licensed maintenance provider within 30 days of the date of revocation. (g) A Homeowner Maintenance Provider whose registration has been revoked will not be allowed to apply for a new registration, and will be required to contract with a licensed maintenance provider to meet TCEQ maintenance, testing, and reporting requirements. (2) Requirements for TCEQ-licensed maintenance providers: (a) In addition to the licensing requirements established in 30 TAC Chapter 285, any TCEQ-licensed maintenance provider who works within the City's jurisdiction for OSSFs must be registered as a TCEQ-licensed maintenance provider with the City. (b) A TCEQ-licensed maintenance provider's registration with the City shall remain in effect until it is suspended or revoked. (3) Suspension and Revocation of Licensed Maintenance Providers' City Registration: (a) The City may suspend a registration issued by the City for failing to comply with: (i) requirements listed in Title 30 TAC Section 285.64(a); (ii) violating Title 30 TAC Section 285.65(a)(1); or (iii) failing to meet deadlines administratively established by the City, or failing to resolve any non-compliance. (b) The City may suspend a licensed maintenance provider's registration for up to six calendar months. (c) A licensed maintenance provider with a suspended registration may not submit new or renewed maintenance contracts to the City, and thus may not enter into new service contracts during the suspension. (d) A licensed maintenance provider with a suspended registration may continue to service existing customers for the duration of the contract with the property owner. (e) The City may revoke a licensed maintenance provider's registration if the provider fails to submit timely monitoring reports. (f) A licensed maintenance provider whose registration is revoked must immediately provide notice to their customers and immediately cease providing maintenance service. (g) A licensed maintenance provider with a revoked registration may not submit new or renewed maintenance contracts to the City, and thus may not enter into new service contracts during the revocation period. (h) A license maintenance provider whose registration is suspended or revoked may request an administrative hearing pursuant to Section 15-9-193 (Administrative Hearing). (i) A licensed maintenance provider with a revoked registration may apply for re-registration after one calendar year from the date of revocation. (F) This subsection establishes additional design criteria. (1) A spray irrigation system may only be used for a single-family residence. Spray irrigation may only be conducted during nighttime hours (after 12:00 AM and before 5:00 AM). The minimum setback to a property line or the residence from the edge of the spray area shall be 25 feet for a spray irrigation system. (2) Soil Absorption Systems following septic tank treatment require a minimum depth to indications of groundwater of 36 inches, measured from the bottom of the media or the bottom of the excavation, whichever is applicable. The use of drip irrigation or low-pressure dosing after septic treatment reduces this vertical separation requirement to 24 inches. (3) An impervious liner must be used between the excavated surface and an evapotranspiration system where 36 inches of suitable soil (as referenced in 30 TAC § 285.91 Table XIII) does not exist between the excavated surface and indications of groundwater. (4) A drainfield may not be installed within the Edwards Aquifer Recharge Zone, as it is defined in Section 15-5-2. unless it follows a City-approved nitrogen reduction system. (5) If a site is not suitable for a standard absorption system based on the criteria of 30 TAC § 285.91 (Table V) and the additional vertical separation criteria of this ordinance, a City-approved nitrogen reduction system must be installed within the Barton Springs Segment of the Edwards Aquifer Contributing Zone. (6) A drainfield may not be installed within 75 feet of the control elevation of Lake Austin unless it follows a City-approved nitrogen reduction system. (7) All aerobic treatment units must be installed with a pretreatment tank or chamber sized at a capacity of at least one-half the average daily design flow. The pretreatment unit must also be designed in accordance with the requirements of 30 TAC § 285.32. (8) Chipped tires are not a permitted drainfield medium. (9) Pump tanks must be large enough to provide at least one day's total average flow between the inlet flow line and the alarm-on level (one day of reserve capacity). (10) All aerobic treatment units must be buried in the ground with access ports at ground level or above. (11) An OSSF for nonresidential sites must dedicate twice the proposed area required for the proposed OSSF for future drainfield expansion unless the Director determines otherwise upon application by the property owner. (12) An OSSF for nonresidential sites must install a flow meter to verify flow rates to the system unless the property owner requests an exemption for the property, and the requested exemption is approved by the Director. (13) The portion of an irrigation system which irrigates a drainfield area shall be valved in order to be isolated from the remainder of the irrigation system. This is necessary in order to prevent over- saturation of a disposal system. (14) When a 10-foot separation between water irrigation lines and OSSF components cannot be obtained, the irrigation systems must be protected by a backflow prevention assembly acceptable to the City to protect the system's water source from contamination. The backflow prevention assembly must be placed at the head of the irrigation system. (G) This subsection establishes additional plan requirements. (1) The installer of an OSSF must follow the approved permitted plan. Any deviation from the approved permitted plan by the installer requires the prior approval of both the system designer and the City. (2) The designer of any professionally designed system will provide both the property owner and the City with an operation and maintenance guide specific for that system. The guide will be reviewed and approved for adequacy by the City prior to the issuance of the permit to construct. (3) All profile holes will be required to have a depth of 36 inches below the bottom of the proposed excavation depth or to a restrictive horizon, whichever is less. Profile holes must be as specified: minimum two feet wide, to the proper depth, and terraced every two feet for access. The soil profile must be examined by either a site evaluator or a professional engineer to determine if there are indications of groundwater within 36 inches of the bottom of the excavation.
Source: Ord. 20131003-097; Ord. No. 20190131-002, Pt. 5, 2-11-19.
Ask a question about Austin law
Corpus searches the Austin sections it holds and shows the ones that match, with their citations. Free, no sign-in.