For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.39.050 — MASS AND SCALE

Anaheim Municipal Code (2026 S-28: local legislation current through Ord. 6627, passed 8-11-2026) · Anaheim Municipal Code § 18.39.050

Corpus is an independent public-information project, not the official City of Anaheim website. Stable reference: corpuslaw.us/code/b402b697-846e-408e-bff6-d0503736cd48

18.39.050 MASS AND SCALE.

.0501 Height Modulation. Buildings greater than forty (40) feet in height shall incorporate at least one of the following: (a) Stepback. Stepback of a minimum depth of six (6) feet (including balconies) for at least seventy-five (75) percent of the façade above forty (40) feet in height, measured from the primary façade plane; or [image omitted; see the official code] Figure 12-B Stepback (b) Roofline Variation. Variation in roof height of at least five (5) feet for every eighty (80) linear feet of façade width; or (c) Height Averaging. Up to thirty (30) percent of the building footprint area may be twelve (12) feet taller than the maximum height allowed, provided an equal amount of building footprint area is twelve (12) feet shorter than the maximum allowed height. [image omitted; see the official code] Figure 12-C Roofline Variation [image omitted; see the official code] Figure 12-D Height Averaging . 0502 Façade Modulation. (a) Horizontal Modulation. 1 . On buildings four floors or more, each street-facing façade (or façade elements created by Vertical Modulation standards below) shall be composed with a clearly distinguishable base and/or top. Buildings shall achieve this horizontal modulation through at least two of the following: i. Changes in façade materials, textures, and/or colors. ii. Changes in type, size, number, and arrangement of façade doors and windows (fenestration patterns), permitting no more than two different types, sizes and arrangements of façade doors and windows (fenestration patterns) for each base, middle, and/or top elements of a building. iii. Use of functional and/or decorative horizontal façade projections or recesses of at least one (1) foot at transition lines between the base, middle, and/or top. iv. Changes in floor-to-floor heights by at least two (2) feet. (b) Vertical Modulation. A design proposal shall comply with the following vertical modulation standards: 1. Minor Modulation. Each street-facing façade (or façade element created by Major Modulation standards below) greater than eighty (80) feet in width shall include a minimum modulation of thirty (30) percent of the façade length that is a minimum of three (3) feet in depth from the primary façade plane. Façade area used to meet this standard may be recessed behind, or project out from, the primary façade plane and may be in one continuous section or a combination of sections across the façade. [image omitted; see the official code] Figure 12-E Minor Modulations 2. Major Modulation. Each street-facing building façade greater than two hundred forty (240) feet or more in width will require a minimum of one major modulation in addition to the minor modulation required in 18.39.050.0502 (Façade Modulation). The major modulation shall be at least six (6) feet in depth and twenty (20) feet in width and extend from grade to the highest story. [image omitted; see the official code] Figure 12-F Major Modulations .0503 Transitional Massing. Buildings greater than forty (40) feet in height and where the project site abuts or is located within one hundred fifty (150) feet of single-family residential zones shall incorporate one of the following strategies in the messing directly adjacent to the single-family residential zone: (a) Stepback. Minimum depth of eight (8) feet at all upper floors above forty (40) feet in height, measured from the primary façade plane; or (b) Height Averaging. Up to thirty (30) percent of the building footprint area may be twelve (12) feet taller than the maximum height allowed, provided an equal amount of building footprint area is twelve (12) feet shorter than the maximum allowed height. Building frontage with increased height shall be located away from adjacent neighboring single-family residential zones. .0504 Corner Elements. Buildings located on a corner lot where at least one of the intersecting streets is classified as an Arterial street in the Circulation Element of the General Plan shall incorporate at least two of the following corner features: (a) Corner feature with a height greater than the adjacent facades by a minimum of five (5) feet. Should surrounding façades be at or near the maximum height allowed by base zoning, the corner feature may project past the maximum height up to ten (10) feet, with a horizontal area of a minimum of twenty (15) feet by twenty (15) feet; or (b) Corner feature with a minimum of six (6) feet recess or projection from the primary façade for a horizontal area of minimum of twenty (20) feet by twenty (20) feet and extend from grade to the building height; or (c) Corner feature with diagonal or curved walls; or (d) Corner feature with primary building entry that includes either canopies or awnings that are oriented diagonal to the intersection; or (e) Corner feature with color and material variation from the primary façade with a horizontal area of minimum of twenty (20) feet by twenty (20) feet; or (f) Public art pursuant to the definition of Public Art and Murals in Chapter 18.36 (Types of Uses); or (g) Corner plazas or gathering areas with distinct paving or landscaping, consistent with standards outlined in Publicly Accessible Recreation-Leisure Space (Section 18.39.040.0404). [image omitted; see the official code] Figure 12-G Corner Elements .0505 Terminating Vistas. Project sites located at the visual termination of any public or private street shall integrate at least two (2) of the following features and located on the centerline of said street: (a) Massing element with a height greater than the adjacent façades by a minimum of five (5) feet. Should surrounding façades be at or near the maximum height allowed by base zoning, the massing element may project past the maximum height up to ten (10) feet, with a minimum of twenty (20) feet linear feet; or (b) Massing element with a minimum of six (6) feet recess or projection from the primary façade with a minimum of twenty (20) linear feet and extend from grade to the building height; or (c) Primary building entry and enhanced canopies or awnings; or (d) Color and material variation from the primary façade with a minimum of twenty (20) linear feet and extend from grade to the building height; or (e) Open space or gathering areas with distinct paving or landscaping, consistent with standards outlined in Publicly Accessible Recreation–Leisure Space (Section 18.39.040.0404); or (f) Covered paseo (consistent with section 18.39.050.0506); or (g) Public art pursuant to the definition of Public Art and Murals in Chapter 18.36 (Types of Uses). [image omitted; see the official code] Figure 12-H Terminated Vistas .0506 Covered Paseos. If covered openings are provided in buildings to allow paseos connecting the public right-of-way to interior courtyards and/or publicly accessible paseos, such openings shall conform to the following requirements: (a) Paseo openings must have at least twenty (20) feet of height clearance from ground to ceiling. (b) A pedestrian bridge or private or public common space may be located twelve (12) feet or higher above ground level. It shall be a maximum of fifteen (15) feet wide and be set back a minimum of nine (9) feet from the primary building façade. The pedestrian bridge shall be open to the air or be glazed for at least 90% of the wall surfaces. (c) Covered paseo openings shall integrate at least two (2) of the following features: 1. Architectural projection around the opening beyond the adjacent facades of one (1) foot or more in depth; or 2. Architectural recess around the opening back from the adjacent facades of one (1) foot or more in depth; or 3. Shaped opening (arch or other profile); or 4. Color and/or material change from adjacent facades around the covered paseo opening; or 5. Architectural features around the opening in accordance with 18.39.050.0504 (Corner Elements) or 18.39.050.0505 (Terminating Vistas). [image omitted; see the official code] Figure 12-I Paseo Opening: Five Stories and Below [image omitted; see the official code] Figure 12-J Paseo Opening: 6 stories and Higher (Ord. 6609 § 23 (part); May 13, 2025)

Ask a question about Anaheim law

Corpus searches the Anaheim sections it holds and shows the ones that match, with their citations. Free, no sign-in.