9-8-2. - Floor Area Ratio Requirements.
(a) Purpose: The purpose of the floor area ratio requirements is to limit the impacts of the use that result from increased building size. (b) Maximum Floor Area Ratio: The maximum floor area ratio on a lot or parcel shall be the greatest of the following: (1) The floor area set forth in this section; (2) The floor area approved prior to June 3, 1997, as part of a valid existing or unexpired planned development (PD), planned residential development (PRD), planned unit development (PUD), or a site review; or (3) The floor area on the lot or parcel on June 3, 1997. (c) Calculating Floor Area Ratios and Floor Area Ratio Additions: The floor area ratio shall be calculated based on all buildings on a lot according to the definitions in Chapter 9-16, B.R.C., 1981, "Floor Area," "Floor Area Ratio," "Uninhabitable Space," and "Basement". In addition to the floor area ratio limitations set forth in Table 8-1, Intensity Standards, B.R.C. 1981, floor area ratio additions may be added above the base floor area ratio and certain floor areas may be excluded from the floor area calculations as set forth in Table 8-2 of this section. TABLE 8-2: FLOOR AREA RATIO ADDITIONS

Footnotes: (a) FAR up to 1.85 if property is located in a general improvement district providing off-street parking. (b) The maximum additional FAR component is 1.0. FAR additional components may be combined, but shall not exceed the 1.0 maximum total floor are ratio limit. (c) See Subparagraph 9-2-14(h)(6)(B), B.R.C. 1981. (d) For properties located in an area designated in Appendix L, "Form-Based Code Areas," and developed pursuant to a form-based code review, the floor area and floor area ratio (FAR) requirements do not apply. Refer to Chapter 9-14, "Form-Based Code," B.R.C. 1981, for specific form, bulk, intensity, and outdoor space requirements. (e) See Subsection 9-6-3(a)(2), B.R.C. 1981. (f) Floor area ratio (FAR) in the RH-2 zoning district may be increased up to a maximum FAR of 1.07 in a site review. (g) FAR in the BT-1 zoning district may be increased up to a maximum FAR of 1.4 in a site review. (h) FAR in the BC zoning districts may be increased up to a maximum FAR of 2.0 provided the lot or parcel is located within an area identified in Appendix N, "Business Community (BC) Areas Subject to Special Use Restrictions." (-) Not applicable. _____ (d) District-Specific Standards: (1) Maximum Floor Area in the RR-1, RR-2, RE, RL-1, RL-2, and RMX-1 Zoning Districts: (A) Purpose: The purpose of a floor area ratio standard is to address the proportionality of building size to lot size and allow variation in building form within the established building envelope. (B) Scope: All construction related to principal and accessory buildings shall comply with the floor area ratio requirements of this section. This section applies to all construction related to residential buildings, including new construction, building additions, or modification of existing buildings as follows: (i) All principal and accessory buildings in the RR-1, RR-2, RE, and RL-1 zoning districts, including lots located in planned developments, planned residential developments, and planned unit developments. (ii) All principal and accessory buildings in the RMX-1 zoning district, including lots located in planned developments, planned residential developments, and planned unit developments. (iii) In the RL-2 zoning district, the floor area ratio requirements shall apply to lots that are 8,000 square feet or larger, used for detached dwelling units that are not within the boundaries of a planned development, planned residential development, planned unit development, or an approved site review. (iv) In the RL-2 zoning district, the floor area ratio requirements shall apply to all lots and parcels used for detached dwelling units that are within the boundaries of a planned development, planned residential development, and planned unit development that are shown on Appendix H to this title. (v) For projects subject to site review in Section 9-2-14, "Site Review," B.R.C. 1981, the floor area shall be calculated based upon each lot or parcel. (C) Maximum Floor Area Permitted: The maximum floor area shall be the floor area that is in Table 8-3, "Maximum Floor Area Ratio in the RR, RE, RL-1, and RMX-1 Zoning Districts." TABLE 8-3: MAXIMUM FLOOR AREA RATIO IN THE RR, RE, RL, AND RMX-1 ZONING DISTRICTS

(D) Floor Area Counted: The maximum floor area allowed includes the floor area of all levels. (i) The amount of contributing floor area of the lowest level shall be calculated as follows: (Length of the perimeter of the wall that is exposed more than 3 feet above adjacent finished grade) ÷ (Total length of the perimeter of the wall) = (the percentage of the floor area that is counted on lowest level). See Figure 8-1. Window wells or door wells shall not be considered an exposed wall if the following standards are met: distance of the opening of the well is no more than four feet, measured perpendicular to the wall; the well does not exceed five feet in length measured parallel to the wall; and the cumulative length of all wells along any front, rear, or side yard does not exceed twenty feet in length for each such yard.

Figure 8-1: Floor Area Ratio Calculation for Lowest Level Floor with Totally or Partially Exposed Walls Wall area A is partially exposed above grade by three feet or less. Wall area B is exposed above grade by more than three feet. For example: (Length of wall B) / (Length of wall A + B) = The percent of floor area calculated towards FAR. (ii) The floor area of a high volume space where the distance between any floor and the bottom of the framed ceiling directly above it is sixteen feet or more shall be counted twice. If the distance between any floor and the bottom of the framed ceiling above it is twenty-six feet or more, the floor area shall be counted three times. Up to 150 square feet of a stairwell shall not be considered a high volume space subject to the requirements of this paragraph.

High Volume Spaces (E) Floor Area Exempt for Accessory Buildings in Historic Districts and associated with Individual Landmarks: Floor area for accessory buildings may be exempted from the maximum floor area permitted if the following standards are met: (i) The accessory building contributes to the historic significance of an individual landmark or a historic district; (ii) The accessory building was built during the individual landmark or historic district's period of significance; (iii) Only that portion of the accessory building built during the period of significance is eligible for an exemption; and (iv) The floor area subject to this exemption is added to another principal or accessory building on the same property and approved as part of a landmark alteration certificate pursuant to Section 9-11-12, "Landmark Alteration Certificate Required," B.R.C. 1981. (2) Maximum Additional Floor Area: (A) In the DT-2 district, the maximum FAR additional components floor area consisting of either residential floor area, parking within the principal building or detached garages that is not included in the FAR calculation is 0.5 FAR. (B) In the DT-5 district, the maximum FAR additional components that can be added to the base FAR in Table 8-2 shall be a floor area ratio of 1.0. Each component of the additional FAR shall not exceed the maximum FAR additional components listed in Table 8-2. To be eligible for the nonresidential floor area, prior to issuance of a building permit, the applicant shall pay the housing linkage fee in Section 4-20-62, "Capital Facility Impact Fee," B.R.C. 1981, for each square foot of additional floor area above the base floor area ratio for which the addition is requested. (3) Floor Area Transfers in the DT-5 Zoning Districts: In the DT-5 district, floor area may be transferred from one lot or parcel to another lot or parcel, as provided for by this paragraph. Approval of a floor area transfer shall permit the transfer of all of the supplemental floor area permitted by Table 8-2 of this section to another lot or parcel and permit the same amount of unrestricted floor area to be constructed on the parcel from which the bonus floor area was sent. A floor area transfer will be approved if the approving authority finds that the following criteria have been met as a part of a site review approval pursuant to Section 9-2-14, "Site Review," B.R.C. 1981: (A) The lot or parcel from which the floor area is transferred is adjacent to, with a common boundary between, the two lots or parcels. Adjacency shall not be affected by the existence of a public right-of-way; (B) Both the sending and receiving lots or parcels are located in the same zoning district as the lot that will receive the additional floor area; (C) The floor area on either lot or parcel does not exceed the floor area allowed, with floor area bonuses for each lot or parcel; and (D) A phasing plan that addresses the timing of the construction of all of the floor area is approved that ensures that the bonus floor area will be constructed prior to or concurrent with any unrestricted floor area that is transferred to another lot or parcel. (4) General Improvement Districts Providing Off-Street Parking: In the BMS district, the FAR may be increased up to 1.85 if the property is located in a general improvement district providing off-street parking. (5) Land Use Intensity and Height Modifications: The floor area ratio in select zoning districts may be increased pursuant to Subsection 9-2-14(h)(6), "Site Review," B.R.C. 1981. Ordinance Nos. 5623 (1994); 5930 (1997); 7079 (2000); 7117 (2001); 7210 (2002); 7351 (2004); 7484 (2006); 7522 (2007); 7535 (2007); 7624 (2008); 7655 (2009); 7684 (2009); 7699 (2009); 7706 (2009); 7710 (2010); 7730 (2010); 7788 (2011); 7813 (2011); 7878 (2012); 7887 (2013); 7921 (2013); 8121 (2016); 8409 (2020); 8515 (2023); 8599 (2024); 8651 (2025); 8666 (2025); 8669 (2025)