For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5-120.1 — Noise level reduction in an APZ Zone 1

Code of Ordinances, City of Tampa (Supp. No. 148: codified through Ordinance No. 2025-152, enacted December 18, 2025) · Tampa City Code § 5-120.1

Corpus is an independent public-information project, not the official City of Tampa website. Stable reference: corpuslaw.us/code/b454fa09-387c-4649-88f7-c660585e3048

Sec. 5-120.1. - Noise level reduction in an APZ Zone 1.

5-120.1.1. Compliance. Compliance with the following standards shall be deemed to meet the requirements of section 27-137.5, City of Tampa Code, as amended, in which an NLR twenty-five (25) db is specified. 5-120.1.2. General. 1. Brick veneer, masonry blocks or stucco exterior walls shall be constructed airtight. All joints shall be grouted or caulked airtight. 2. At the penetration of exterior walls by pipes, ducts or conduits the space between the wall and pipes, ducts or conduits shall be caulked or filled with mortar. 3. Window and/or through-the-wall ventilation units shall not be used. 4. Through-the-wall/door mailboxes shall not be used. 5-120.1.3. Exterior walls. 1. Except as provided in sections 119.1.3(2) and (c)(3), Florida Building Code, exterior walls shall have a laboratory sound transmission class rating of at least STC-39. 2. At least one (1) surface of concrete block walls shall be plastered or painted with heavy "bridging" paint. 3. Stud walls shall be at least four (4) inches in nominal depth and shall be finished on the outside with siding-on-sheathing, stucco or brick veneer. a. Interior surface of the exterior walls shall be of gypsum board or plaster at least one-half (½) inch thick, installed on the studs. b. Continuous composition board, plywood or gypsum board sheathing at least one-half (½) inch thick shall cover the exterior of the wall studs behind wood, or metal siding. Asphaltic or wood shake shingles are acceptable in lieu of siding. c. Sheathing panels shall be butted tightly and covered on the exterior with overlapping building paper. The top and bottom edges of the sheathing shall be sealed. d. Insulation material at least two (2) inches thick shall be installed contiguously throughout the cavity space behind the exterior sheathing and between wall studs. Insulation shall be glass fiber or mineral wool. 5-120.1.4. Windows. 1. Except as provided in sections 119.1.4(2) through (6), Florida Building Code, windows shall have a laboratory sound transmission class rating of at least STC-28. 2. Glass shall be at least three-sixteenth ( 3/16 ) inches thick. 3. All operable windows shall be weather-stripped and airtight when closed so as to conform to an air infiltration test not to exceed one-half (0.5) cubic foot per minute per foot of crack length in accordance with ASTM (American Society for Testing Materials) E-283-65-T. 4. Glass of fixed-sash windows shall be sealed in an airtight manner with a nonhardening sealant, or a soft elastomer gasket or glazing tape. 5. The perimeter of window frames shall be sealed airtight to the exterior wall construction with a sealant conforming to one (1) of the following Federal Specifications: TT-S-00227, TT-S-00230 or TT-S-00153. 6. The total area of glass in both windows and doors in sleeping spaces shall not exceed twenty (20) percent of the floor area. 5-120.1.5. Doors. 1. Except as provided in section 119.1.5(2) through (5), Florida Building Code, doors shall have a laboratory sound transmission class rating of at least STC-28. 2. All exterior side-hinged doors shall be solid-core wood or insulated hollow metal at least one and three-fourths (1¾) inches thick and shall be fully weather stripped. 3. Exterior sliding doors shall be weather stripped with an efficient airtight gasket system with performance as specified in section 119.1.4(3), Florida Building Code. The glass in the sliding doors shall be at least three-sixteenths ( 3/16 ) inches thick. 4. Glass in doors shall be sealed in an airtight non-hardening sealant, or in a soft elastomer gasket or glazing tape. 5. The perimeter of door frames shall be sealed airtight to the exterior wall construction as described in section 119.1.4(5), Florida Building Code. 5-120.1.6. Roofs. 1. Except as provided in sections 119.1.6(2) and (3), Florida Building Code, combined roof and ceiling construction shall have a laboratory sound transmission class rating of at least STC-39. 2. With an attic or rafter space at least six (6) inches deep, and a ceiling below, the roof shall consist of closely butted one-half-inch composition board, plywood or gypsum board sheathing topped by roofing as required. 3. Window or dome skylights shall have a laboratory sound transmission class rating of least STC-28. 5-120.1.7. Ceilings. 1. Gypsum board or plaster ceilings at least one-half (½) inch thick shall be provided where required by section 119.1.6(2), Florida Building Code. Ceilings shall be substantially airtight, with a minimum number of penetrations. 2. Class fiber or mineral wool insulation at least two (2) inches thick shall be provided above the ceiling between joists. 5-120.1.8. Floors. Openings to any crawl spaces below the floor of the lowest occupied rooms shall not exceed two (2) percent of the floor area of the occupied rooms. 5-120.1.9. Ventilation. 1. A mechanical ventilation system shall be installed that will provide air circulation and fresh air supply in occupied rooms without the need to open any windows, doors or others openings to the exterior. 2. Gravity vent openings in attic shall not exceed code minimum in number and size. 3. If a fan is used for forced ventilation, the attic inlet and discharge openings shall be fitted with sheet metal transfer ducts of at least twenty-gauge steel, which shall be lines with one-inch thick coated glass fiber, and shall be at least five (5) feet long with one (1) ninety-degree bend. 4. All vent ducts connecting the interior space to the outdoors, excepting domestic range exhaust ducts, shall contain at least a five-foot length of internal sound absorbing duct lining, except where nonabsorbent material is required by local codes. Each duct shall be provided with a bend in the duct such that there is no direct line of sight through the duct from the venting cross section to the roomopening cross section. 5. Duct lining shall be coated glass fiber duct liner at least one (1) inch thick. 6. Fireplaces shall be provided with well-fitted dampers. 5-120.1.10. Alternate methods of construction. The provisions of this chapter are not intended to prevent the use of any material or method of construction not specifically prescribed by this chapter, provided the alternate has been approved by the building official. The alternate shall include a certification that a twenty-five (25) db noise level reduction is achieved by the proposed method of construction.

(Ord. No. 2024-15, § 2(Exh. A), 2-1-2024)

Ask a question about Tampa law

Corpus searches the Tampa sections it holds and shows the ones that match, with their citations. Free, no sign-in.