Sec. 48-587. - Residential structures and residential portions of mixed use structures.

(a) Elevation requirements. (1) The lowest floor (including basement) shall be elevated to or above the base flood elevation plus 18 inches. (2) In areas of shallow flooding (Zone AO), the lowest floor (including basement) shall be elevated at least as high above the highest adjacent grade as the depth number specified in feet on the flood insurance rate map plus 18 inches, or at least two feet plus 18 inches if a depth number is not specified; adequate drainage paths shall be provided to guide floodwaters around and away from the structure. (3) Enclosures below the lowest floor shall meet the requirements of subsection (b). (b) Enclosures below the lowest floor. (1) Enclosures below the lowest floor shall be used solely for parking of vehicles, building access, crawlspaces, or limited storage. (2) Enclosures below the lowest floor shall be constructed using flood damage-resistant materials. See FEMA Technical Bulletin #2 — Flood Damage-Resistant Materials Requirements. (3) Enclosures below the lowest floor (including crawlspaces) shall be provided with flood openings which shall meet the following criteria (see FEMA Technical Bulletin #1 — Openings in Foundation Walls and Walls of Enclosures): a. There shall be a minimum of two openings on different sides of each enclosed area; if a building has more than one enclosed area below the base flood elevation, each area shall have openings on exterior walls. b. The total net area of all openings shall be at least one-square-inch for each square foot of enclosed area, or the openings shall be designed and certified by a registered engineer or architect to provide for equalization of hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwaters. c. The bottom of each opening shall be one-foot or less above the adjacent ground level. d. Any louvers, screens or other opening covers shall allow the automatic flow of floodwaters into and out of the enclosed area. e. Where installed in doors and windows, openings that meet requirements of subsection (b)(3)a. through (b)(3)d., are acceptable; however, doors and windows without installed openings do not meet the requirements of this section. (4) Crawlspaces shall have the finished interior ground level equal to or higher than the outside finished ground level on at least one entire side of the foundation wall. (c) Manufactured homes. New or replacement manufactured homes, including substantial improvement of existing manufactured homes, shall: (1) Be elevated on a permanent, reinforced foundation that raises the lowest floor to or above the base flood elevation plus 18 inches and is otherwise in accordance with subsection (a). (2) Be installed in accordance with the anchor and tie-down requirements of the building code or the manufacturer's written installation instructions and specifications. (3) Have enclosures below the elevated manufactured home, if any, meet the requirements of subsection (b). For the purpose of this requirement, the lowest floor of a manufactured home is the bottom of the lowest horizontal supporting member of the lowest floor.

(Ord. No. 14-053(sub 1), § 2, 12-18-14)

Ask a question about Wilmington law

Corpus searches the Wilmington sections it holds and shows the ones that match, with their citations. Free, no sign-in.