For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10.13.430 — Construction and maintenance sanitation standards for MPRAF establishments

Seattle Municipal Code (Supp. No. 44: codified through Ordinance No. 127459, passed June 30, 2026) · Seattle Mun. Code ch. 10.13, subch. IV, § 10.13.430

Corpus is an independent public-information project, not the official City of Seattle website. Stable reference: corpuslaw.us/code/b62e84bf-20d6-43dd-9a29-7ce426822e92

10.13.430 - Construction and maintenance sanitation standards for MPRAF establishments.

Every structure used as a MPRAF establishment shall satisfy the following sanitation standards: A. Structure, Generally. Every structure in or from which an MPRAF establishment operates shall be of sound construction and shall be kept in good repair. Dust, spiders, rodents, and insects shall be prevented from entering or remaining in or on such structure. B. Walls, Ceilings, and Floor. The walls, ceiling and floor of every area of an MPRAF establishment where MPRAF or any MPRAF food product is prepared, processed, dispensed, or stored shall have a smooth, hard, and water-and grease-impervious surface. C. Ventilation. Every area of an MPRAF establishment where MPRAF or any MPRAF food product is prepared, processed, dispensed, or stored shall be adequately ventilated to prevent condensation and to remove obnoxious odors, smoke and steam. Ventilation systems shall be installed and operated according to the Seattle Mechanical Code (Seattle Municipal Code, Title 22, Subtitle IV or its successors). D. Lighting. Every area of an MPRAF establishment where MPRAF or any MPRAF food product is prepared, processed, dispensed, or stored shall be lit consistent with the following requirements: 1. Permanently fixed artificial light sources shall be installed to provide at least twenty (20) footcandles of light on all MPRAF preparation surfaces and at equipment or utensil-washing work levels. 2. Permanently fixed artificial light sources shall be installed to provide, at a distance of thirty inches (30") from the floor: a. At least twenty (20) footcandles of light in utensil and equipment storage areas and in lavatory and toilet areas; and b. At least ten (10) footcandles of light in walk-in refrigerating units and in all other areas. 3. Shielding to protect against broken glass falling onto MPRAF or any MPRAF food product shall be provided for all artificial lighting fixtures located over, by, or within MPRAF preparing, processing, dispensing, or storage facilities, and areas where utensils and equipment are cleaned and stored. 4. Infrared or other heat lamps shall be protected against breakage by a shield surrounding and extending beyond the bulb, leaving only the face of the bulb exposed. E. Plumbing. 1. General. All plumbing shall satisfy the requirements of the Seattle Plumbing Code (Seattle Municipal Code, Title 22, Subtitle V or its successors). 2. Lavatory Facilities. Each MPRAF establishment shall be provided with adequate, conveniently located, hand-washing facilities for its personnel, including a lavatory equipped with hot and cold or tempered running water, hand-cleansing soap or detergent, and disposable or approved sanitary towels or other approved hand-drying devices. Such facilities shall be kept in good repair and shall be accessible to such personnel at all times. Lavatories shall be located in or immediately adjacent to toilet rooms or vestibules. Handwashing facilities shall not be used for food preparation or for washing equipment or utensils. Sinks used for MPRAF preparation or for washing equipment or utensils, or for general cleanup shall not be used for handwashing. 3. Toilet Facilities. Toilet facilities, adequate in number for the number of personnel of an MPRAF establishment, as presented by the Seattle Plumbing Code (Seattle Municipal Code, Title 22, Subtitle V, or its successor), shall be provided on the premises of each such establishment, and shall be conveniently located and accessible to such personnel at all times. Toilet rooms shall be completely enclosed and shall have tight-fitting, self-closing, solid doors, which shall be closed except during access, cleaning, or maintenance. Toilet rooms shall be separated, by a self-closing door, from areas of the MPRAF establishment where MPRAF is prepared, processed, dispensed, or stored. Toilet rooms shall be ventilated consistent with the requirements of the Seattle Building and Plumbing Codes (Seattle Municipal Code, Title 22, Subtitles I and V or their respective successors). A reasonable supply of toilet tissue shall be provided at each toilet at all times. F. Dressing Room or Area. Each MPRAF establishment shall provide a room or area with convenient clothes-storage facilities for clothes-changing by personnel, which area shall be separated by a self-closing door from the areas where MPRAF is prepared, processed, dispensed or stored. G. Garbage and Refuse Containment Areas. Garbage or refuse storage rooms, if used, shall be constructed of easily cleanable, nonabsorbent, washable materials and shall be spider-, rodent-, and insect-proof. Outside storage areas or enclosures or inside garbage or refuse storage rooms shall be large enough to store all necessary garbage or refuse containers. Garbage and refuse containers and compactor systems located outside shall be stored on or above a smooth surface of nonabsorbent material, such as concrete or machine-laid asphalt that is maintained in good repair.

(Ord. 110052, § 1, 1981).

Ask a question about Seattle law

Corpus searches the Seattle sections it holds and shows the ones that match, with their citations. Free, no sign-in.