5.5 - SPECIFIC TO URBAN CENTER TRANSECT ZONES (T5)

5.5.1 Building Disposition (T5) a. Newly platted lots shall be dimensioned according to Section 5.5.11 b. Buildings shall be disposed in relation to the boundaries of their lots according to Section 5.5.11. c. One principal building at the Frontage and one Outbuilding to the rear of the principal building may be built on each lot as shown in Table 16C. d. Lot coverage by building shall not exceed that shown in Section 5.5.11. e. Facades shall be built parallel to the Principal Frontage Line, and shall be built out along a minimum of 70% of the length of the Principal Frontage Line as measured at the actual Facade Setback. A Streetscreen shall be built co-planar with the Facade along the unbuilt length of the Principal Frontage Line in accordance with 5.5.5b. f. Setbacks for Principal Buildings shall be as shown in Section 5.5.11 and on Table 14l. In the case of an Infill lot, front Setbacks shall match one or the other of the existing adjacent Setbacks, so long as the resulting Setback conforms with the requirements of Table 14l. Setbacks may otherwise be adjusted by Warrant. g. Rear Setbacks for Outbuildings shall be a minimum of 12 feet measured from the centerline of the Alley or Rear Lane easement. In the absence of a Rear Alley or Lane, the rear Setback shall be as shown in Section 5.5.11. h. Building Types shall be as shown in Table 9. i. [RESERVED] j. Buildings shall have their principal pedestrian entrances on a Frontage Line. 5.5.2 Building Configuration (T5) a. Private Frontage types shall conform to and be allocated in accordance with Table 7 and Section 5.5.11. b. Awnings may encroach the public sidewalk without limit. Stoops may encroach 100% of the depth of a Setback. Open porches and awnings may encroach up to 50% of the depth of the Setback. Balconies and bay windows may encroach up to 25% of the depth of the Setback. c. Loading docks and service areas shall be permitted on Frontages only by Warrant. d. Building Heights shall conform to Table 8 and be as shown in Section 5.5.11. e. A first level Residential or Lodging Function shall be raised a minimum of 2 feet from average sidewalk grade. f. Building Height shall be measured from the Height Baseline appropriate to the site: outside Flood Hazard Areas regulated by the City's Flood Damage Prevention Ordinance, the Height Baseline shall be the average grade at the primary Frontage Line for the lot; inside areas regulated by the City's Flood Damage Prevention Ordinance, the Height Baseline shall be the Minimum Buildable Elevation. Any vertical offset of more than 4 feet between the Height Baseline and the finish surface of the first floor above the Height Baseline shall be counted as a complete Story in determining the height of the building. g. No Story shall exceed 14 feet in height, measured from floor to ceiling. h. Any Basement-level space required for compliance with Flood Ordinance requirements in excess of 8 feet and not contained within a filled foundation or chain-wall foundation shall be designed for use as (i) parking or storage space set into the structure into the second and deeper Layers, and concealed from view from all streets, (ii) an open market, loggia, porch, or combination thereof, or other open-air area for recreation, relaxation or gathering, (iii) enclosed commercial or retail space to the extent permitted by applicable FEMA requirements and T5 Zone usage limits, or other use permitted by the Planning Office. 5.5.3 Building Function & Density (T5) a. Buildings in each Transect Zone shall conform to the Functions described in Tables 10 and 11 and Section 5.5.11. Any function not listed in this table is subject to CRC warrant appealable to the Planning Commission by way of a written appeal of the decision of the CRC submitted to the Planning Office (within the Department of Urban Development) within fifteen (15) days after the decision of the CRC. b. Function Volume accommodated on a lot shall be limited by the ability of Available Parking to meet the parking requirement corresponding to the Function Volume. However, under no circumstances may the Function Volume accommodated on the lot exceed the Density Allowance for that lot. c. The parking requirement for any Function associated with a building may be reduced where on-site parking spaces required for two distinct Functions are physically and practicably accessible within the same facility to vehicles associated with the different uses. To compute the reduction in spaces required for each of the two Functions, divide the smaller of the parking requirements for the two Functions by the appropriate Sharing Factor from Table 12, then subtract the result from the smaller of the two parking requirements. This difference is one-half the Effective Parking Bonus, and the original parking requirement for each of the two Functions may be reduced by one-half the Effective Parking Bonus. Effective Parking Bonuses shall only be permitted for distinct Functions pair-wise. To qualify for any Effective Parking Bonus, the parking spaces included in the calculation for both Functions shall be on the usage site generating the requirements, publicly available, and mutually accessible. d. Within the Long Pedestrian Shed of a TOD, the Effective Parking available for calculating the Function Volume permitted on each lot may be increased by twenty-five percent (25%), or conversely, the parking requirement for a particular Function Volume may be reduced by twenty percent (20%). e. Accessory uses of Limited Lodging or Limited Office shall be permitted within an Outbuilding. f. First Story Commercial shall be permitted throughout and shall be required at Mandatory Shopfront Frontages. g. A Home Occupation operated by the property owner is permitted by right in any single Story or Outbuilding of a fee-simple lot, subject to the functional limitations stated in Article 7 (Definitions). Home Occupation requires no additional parking for a lot in a T5 Zone. h. [RESERVED] i. [RESERVED] j. Adjusted Density is further modified and limited according to Section 5.5.12. k. Manufacturing within the first Story may be permitted by Planning Commission Approval. 5.5.4 Parking Standards (T5) a. Vehicular parking shall be required as shown in Tables 11 and 12 in conjunction with Sections 5.1.9 and 5.5.3. b. Publicly available on-street parking along the Frontage Lines of a lot shall be counted toward the parking requirement of the Retail Functions of the building on the lot, subject to the requirement that the lot owner provides and dedicates to the City parking meters and street tree plantings along the Frontage Lines according to the specifications of the Community Plan and the CRC. c. Maximum parking ratios and maximum on-site parking ratios may be established by the CRC. d. [RESERVED] e. Bicycle rack space for a minimum of one (1) bicycle shall be provided within the Public or Private Frontage for every ten vehicular parking spaces. f. All parking areas shall be located at the Third Lot Layer. g. Parking shall be accessed by the Alley or Rear Lane when such are available on the Community Plan. h. The vehicular entrance of a parking lot or garage on a Frontage shall be no wider than 30 feet. i. View of parking lots and parking garages shall be masked from the Frontage by a Liner Building or other buildings or Streetscreen as specified in Section 5.5.5b. Parking requirements shall be waived for Functions in Liner Buildings of twenty-five (25) feet depth or less constructed to screen Public-Parking Facilities. j. Reduction of impervious surfaces through the use of interlocking pavers, compacted oyster shell, or other pervious paving on a list of materials approved and maintained by the Urban Design Center and the City Architect shall be permitted by right for all surface parking lots in T5 Zones. k. Primary pedestrian entrances to all surface parking lots and all Public-Parking Facilities shall be directly from a Frontage Line or from a Frontage Line by way of a Cross-Block Pedestrian Passage. All parking areas provided on-site shall have prominently marked, direct, easy pedestrian access to a Frontage street. Any direct entrance to a Principal Building from a Public-Parking Facility shall be via Unadvertised Secured Entry Door and shall not be publicly accessible. However, for buildings whose principal purpose is to provide Public Parking and which comprise a parking structure and Liner Building without additional Retail, Office, Lodging, or Residential floor space beyond that provided in the Liner Building, pedestrian access may require passage through the Liner Building. This provision shall not be adjusted or eliminated by Warrant. l. For buildings on Secondary Grids (S-Grids), parking lots may be allowed on the Frontage by Warrant (see Section 5.8.1a). m. Required parking may be provided within one-quarter mile of the site that it serves by Right. Required parking may be provided more than one-quarter mile from the site provided that transit is provided between the site and the remote parking area, subject to approval by Warrant. n. All parking in T5 Zones shall be Unbundled if located within a City Center, RCD, or other designated Unbundled Parking Area appearing on the Community Plan. This requirement shall not be adjusted or eliminated by Warrant. o. For T5 Zones within a City Center, RCD, or an Unbundled Parking Area, at least one-half the parking spaces required for a proposed building or renovation of an existing building shall be provided off-site in a Public-Parking Facility within one-quarter mile (¼ mi), independent of the number of parking spaces provided on-site. The distance limit may be increased to one-half mile (½ mi) by Warrant, subject to provision m above. p. For T5 Zones within a City Center, RCD, or an Unbundled Parking Area, all on-site parking spaces shall be provided as part of a Public-Parking Facility. The maximum number of parking spaces which may be provided on-site in a T5 Zone within a City Center, RCD, or an Unbundled Parking Area shall be 150% of the parking requirement for the site. q. Parking requirements for the planned usage of a proposed building or renovation in a T5 Zone may be satisfied by payment to the City's Public-Parking Fund of In-Lieu Fees in accordance with the City's Parking Reform Ordinance, if one exists. 5.5.5 Architectural Standards (T5) The following are general city-wide requirements, and may be modified or overruled by Community Architectural Guidelines adopted as part of the Official Community Plan: a. Building wall materials may be combined on each Facade only horizontally, with the heavier below the lighter, relative weights being determined for approved materials by the Urban Design Center. b. Streetscreens should be between 4 and 8 feet in height and constructed of a material matching the adjacent building Facade. The Streetscreen may be replaced by a hedge or fence approved by the City Architect or the Urban Design Center by Warrant. Streetscreens shall have openings no larger than necessary to allow automobile and pedestrian access. A single length of Streetscreen along a Frontage, including any pedestrian and vehicle openings, may be no longer than 70 feet maximum. c. All openings, including porches, galleries, arcades and windows, with the exception of storefronts, shall be square or vertical in proportion, with width no greater than height. With the exception of storefronts, two adjacent openings in a Facade shall be separated by a distance not less than one-half the width of the smaller of the openings. d. Openings above the first Story shall not exceed 50% of the total building wall area for each Facade, with each Facade being calculated independently. Openings in the Facade above the fourth Story shall include closeable panels, screens, or glass doors which shall remain closed when not in use. e. The Facades on Retail Frontages shall be detailed as storefronts and glazed with clear glass no less than 70% of the sidewalk-level Story. f. Doors and windows that operate as sliders are prohibited along Frontages. g. No Unarticulated length of Facade at street level shall exceed twenty (20) feet. h. Buildings may have flat roofs enclosed by parapets or sloped roofs. Pitched roofs shall be symmetrically sloped no less than 5:12, except that porches and attached sheds may be no less than 2:12. i. Flat roofs shall be enclosed by parapets a minimum of 42 inches high, or higher as required to conceal mechanical equipment to the satisfaction of the CRC. j. The exterior finish materials on all Facades shall be limited to stone, brick and stucco; or to such other materials as shall appear on a list maintained and approved by the Urban Design Center and the City Architect. k. Balconies, galleries and arcades shall be made of concrete, painted wood or metal, or shall be clad in painted solid PVC, urethane, or similar painted solid synthetic trim, or shall be constructed of or clad in such other materials as shall appear on a list maintained and approved by the Urban Design Center and the City Architect. Above the fourth Story, balconies projecting more than twelve inches (12 in) from the Facade shall be counted in their full projection as the outer plane of that Facade for purposes meeting of setback, Stepback, and Buildout-at-Height requirements. Above the second Story no balcony projecting from a Facade shall not extend to a width greater than 50% of the width of that Facade. Above the fourth Story, a balcony's width shall not exceed 150% of the width of the Facade openings providing access to the balcony. l. Streetscreens shall be located coplanar with the building Facade line as shown in Table 16D. m. Subject to the other requirements of this Code, including without limitation Article 5, any building designed in a manner consistent with the publication entitled "A Pattern Book for Gulf Coast Neighborhoods" shall be permitted as of right on certification of such by the Urban Design Center or City Architect. n. Within any Historic District established or recognized by the Mayor and City Council, or with respect to any Historic Structure or Historic Site so established or recognized, each building and structure, and its improvement, alteration, addition, or reconstruction, shall comply with the Historical Architectural Guidelines of the City's Historical Commission, if one has been established by an Ordinance approved by the Mayor and City Council, and shall be subject to approval by the City Architect and the Historical Commission. o. Within any Community Planning Area subject to Community Plans which require Architectural Review in some or all districts, buildings other than single-family residences and their associated ancillary buildings shall be subject to approval of the City Architect in accordance with the City's Architectural Review Ordinance if such exists. p. [RESERVED] 5.5.6 Environmental Standards (T5) a. Transect Zones manifest a range of responses to natural and urban conditions. In case of conflict, to the extent not inconsistent with applicable state or federal law, the natural infrastructure shall have priority in the more rural zones (T1-T3) and the urban infrastructure shall have priority in the more urban zones (T4-T6) as detailed in Sections 5.2 through 5.6. b. The landscape installed shall consist primarily of durable native species tolerant of soil compaction. c. Impermeable surface by building shall be confined to the ratio of lot coverage as shown in Table 14H. d. To the extent not inconsistent with applicable state or federal law, city ordinance, or overlay district requirements, management of storm water shall be primarily off-site through underground storm drainage, and there shall be no retention or detention required on the individual lot. e. Within T5 Zones, building roofs shall be constructed as Cool Roofs where this requirement does not conflict with architectural standards, guidelines, and requirements of this Code or the Community Plan. 5.5.7 Landscape Standards (T5) a. Trees shall not be required in the First Layer (Table 16D). b. [RESERVED]. c. The First Layer as shown in Table 16D shall be landscaped or paved to match the Enfronting Public Frontage as shown in Table 4. d. Trees shall be a species with shade canopies that, at maturity, attain a height beyond the tops of the second Stories of buildings, and which do not visually obstruct the first Story; however, quick-growth trees used for short-term shade production and designated on the Community Plan to be replaced with more long-lived species on a specified schedule shall be permitted without restrictions to shade canopy height. e. Trees and shrubs on a list of invasive, problematic, or undesirable species maintained by the Urban Design Center shall not be used in any Landscaping of any kind in Zone T5. 5.5.8 Signage Standards (T5) a. All provisions of the City's separate Comprehensive Sign Ordinance shall continue to be applicable, according to the City of Gulfport's Code of Ordinances, Article IV. Signs, Chapter 9 Planning and Development, section 9-91, Signs in B-1, B-2, B-4, I-1, I-2, I-3 districts. 5.5.9 Ambient Standards (T5) a. Sound levels measured at the building Frontage shall not exceed 70 decibels from sunrise to midnight and 60 decibels from midnight to sunrise. All provisions of the City of Gulfport Noise Ordinance shall continue to be applicable, and where in conflict herewith, the stricter provision shall apply. b. Permanent outdoor Luminaires other than those which are Fully Shielded shall be so equipped as not to exceed a total lamp power of 40 Watts per Luminaire for Incandescent Lamps, or of 10 Watts per Luminaire for non-Incandescent Lamps. c. The mounting height of a permanent outdoor Luminaire which is attached directly to the Facade or Elevation of a building shall not exceed 12 feet, where mounting height is measured from the topmost point of the Luminaire. For a permanent outdoor Luminaire supported by any other means, mounting height shall be limited to the lesser of one-third the distance from the Luminaire to any property line or 32.5 feet, adjustable by Warrant. d. Streetlights shall be Fully Shielded or Nearly Fully Shielded and of a general type illustrated in Table 5. e. Outdoor storage shall be screened from view from any Frontage by a Streetscreen in conformance with Section 5.5.5b. 5.5.10 [RESERVED] [image omitted; see the official code] 5.5.12 Building-Scale Density Limits, Transfers, and Bonuses (T5) a. [RESERVED] b. Lots within T5 Zones shall be eligible for inclusion in both Density Transfer Receiving Areas and Density Bonus Receiving Areas as designated on the Community Plan. c. Lots in T5 Zones may be designated on the Community Plan as Density Sending Areas. Such a lot carries Density Rights equal to the By-Right Density Allowance for the lot. The Density Transfer transaction shall be handled in accordance with Section 1.7.3.

(Ord. No. 3245, § 3, 3-3-23) (Ord. No. 2627, § 4, 4-21-09)

Ask a question about Gulfport law

Corpus searches the Gulfport sections it holds and shows the ones that match, with their citations. Free, no sign-in.