For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 35.23 — 1002.5 Floor Drains

Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 35.23

Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/b6996c49-079a-4d09-a659-7ee636b18d88

35.23 - 1002.5 Floor Drains.

Section 1002.5 Floor Drains is added as follows: A three inch or larger floor drain branch shall be taken off at least five feet from the base of a stack and may extend a maximum of twelve feet (12') developed length without re-venting. Floor drains with the crown weir of the trap elevated above the flow line of the waste line shall be vented or increased by one size minimum. A water closet cannot flush past a floor drain unless the floor drain is vented properly. (041-25)

Ask a question about Cedar Rapids law

Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.