For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.40.520 — Add CBC Section 2305.4—Hold-down connectors

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.40.520

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/b6ac3510-88ff-49f2-96c2-e971b7181f8a

18.40.520 - Add CBC Section 2305.4—Hold-down connectors.

Section 2305.4 is added to Chapter 23 of the California Building Code to read as follows: 2305.4 Hold-down connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product. Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be tightened to finger tight plus one-half (½) wrench turn just prior to covering the wall framing.

(ORD-25-0019 § 1(Exh. A), 2025)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.